TETPOR AIR-Rev 3A
TETPOR AIR-Rev 3A
TETPOR AIR-Rev 3A
Performance Characteristics
900 1000
14
12 900
800 0 barg 2 barg
Differential Pressure (mbar)
0 barg 11
Differential Pressure (psi)
800 12
700 10
9 700 10
600
2 barg 8 600
500 7 8
500
400 6
400 6
5
300
4 300
4
200 3
200
2 2
100 100
1
0 0 0 0
0 100 200 300 400 500 600 700 0 20 40 60 80 100 120 140 160 180
Flow (Nm / hr) (air @ 21 °C)
3
Flow (Nm / hr) (air @ 21 °C)
3
Specifications
Materials of Construction Effective Filtration Area (EFA) Quality Standards
Filtration Membrane: Expanded PTFE 10¨ (250 mm): 0.77 m2 (8.28 ft2) Pharmaceutical grade products are
Upstream Support: Polypropylene K Size: 0.36 m2 (3.87 ft2) manufactured in accordance with cGMP,
Downstream Support: Polypropylene A Size: 0.25 m2 (2.69 ft2) 100% flushed with pharmaceutical grade
B Size: 0.12 m2 (1.29 ft2) purified water and integrity tested prior to
Filter Cartridges E Size: 0.06 m2 (0.64 ft2) despatch. A sample of each lot is tested to
Inner Support Core: Polypropylene Syringe ø50 mm: 14.50 cm2 (2.25 in2) demonstrate conformity to validated claims.
Outer Protection Cage: Polypropylene
End Caps: Polypropylene Sterilisation
End Caps Insert: 316L Stainless Steel Autoclave Steam-in-Place
Standard o-rings/gaskets: Silicone Cycles Temp Cycles Temp
(30 min.)
MURUS Disposable Filter Capsules Cartridges 120 142 °C (287.6 °F) 120 142 °C (287.6 °F)
MURUS 5 130 °C (266 °F) - -
Core: Polypropylene
DEMICAP 100 135 °C (275 °F) - -
Sleeve: Polypropylene
Syringe 1 130 °C (266 °F) - -
Standard o-rings: Viton
Capsule Body: Polypropylene TETPOR AIR filter cartridges can be
Capsules Vent Seals: Silicone sanitised with hot water at up to 90 °C
(194 °F) and are compatible with a wide
DEMICAP Filter Capsules range of chemicals.
Core: Polypropylene
Sleeve: Polypropylene For detailed operational procedures and
End Caps: Polypropylene advice on cleaning and sterilisation, please
Capsule Body: Polypropylene contact the Technical Support Group through
Capsules Vent Seals: Silicone your usual Parker domnick hunter contact.
Filling Bell: Polycarbonate
Food and Biological Safety
Syringe Filters Materials conform to the relevant
Body: Polypropylene requirements of 21CFR Part 177 and current
USP Plastics Class VI - 121 °C and
Recommended Operating Conditions ISO10993 equivalents.
Filter Cartridges
Up to 70 °C (158 °F) continuous operating
temperature and higher short-term
temperatures during CIP to the following
limits:
Temperature Max. Forward dP
°C °F (bar) (psi)
20 68 5.0 72.5
40 104 4.0 58.0
60 140 3.0 43.5
80 176 2.0 29.0
90 194 1.7 24.6
Performance Characteristics
TOC / Conductivity Oxidisable Substances Retention Characteristics
The filtrate quality from a 10¨ (250 mm) TETPOR AIR filter cartridges meet TETPOR AIR filter cartridges are
TETPOR AIR conforms to the requirements current USP and EP quality standards for validated by bacterial challenge testing with
of current USP <643> (TOC) and USP <645> sterile purified water for oxidisable Brevundimonas diminuta to current ASTM
(conductivity). substances following a <1 litre water flush. F838-05 methodology (107 organisms / cm2
EFA minimum) with typical in-house
Endotoxins Integrity Test Data challenge levels being 1011 organisms per
Aqueous extracts from the 10¨ (250 mm) All filters are integrity testable to the 10¨ (250 mm) filter cartridge.
TETPOR AIR contain < 0.25 EU / ml when following limits when wet with 60 / 40 :
tested in accordance with the Limulus IPA /water and using air as the test gas.
Amoebocyte Lysate test. Cartridge Test Diffusional Water Water Water
Pressure Flow Intrusion Intrusion Flow
Test Pressure
Non-Volatile Extractables (NVE) (barg) (psig) (ml / min) (barg) (psig) (ml / 10 min) (µl / 10 min)
Total NVEs extracted in the first 5 litre E 0.8 11.6 1.5 2.5 36.3 1.3 371
flush of purified water for a 10¨ (250 mm) B 0.8 11.6 3.0 2.5 36.3 2.6 742
A 0.8 11.6 6.0 2.5 36.3 5.3 1514
cartridge are <5 mg.
K 0.8 11.6 8.5 2.5 36.3 7.5 2142
10¨ 0.8 11.6 18.0 2.5 36.3 16.0 4571
Pharmaceutical Validation
A full validation guide is available upon
request from Laboratory Services Group
(LSG).
TETPOR AIR Filter Cartridges
Ordering Information
Cartridges
ZCMT / -A
Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Endcap (10¨) Code ǀ O-rings
B 2.5¨ (65 mm) 020 0.2 µm B dh DOE E EPDM
A 5¨ (125 mm) C BF / 226 Bayonet P PTFE
K 5¨ (125 mm) G Recess / 222 S Silicone
1 10¨ (250 mm) R BF / 222 Bayonet V Viton
2 20¨ (500 mm)
3 30¨ (750 mm) Code ǀ Endcap (Demi)
SK Retrofit
T TRUESEAL
Y Demi Stub
Z Demi A & B Std
MURUS Capsules
ZLMT / - -
Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Inlet Connection Code ǀ Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Design Code ǀ O-rings1
K 5¨ (125 mm) 020 0.2 µm A / ¨ Tri-Clamp
3 4
A / ¨ Tri-Clamp
3 4
P Pharmaceutical N Non-sterile L In-Line E EPDM2
1 10¨ (250 mm) B 11/2¨ Tri-Clamp B 11/2¨ Tri-Clamp T T-Port S Silicone
2 20¨ (500 mm) D 1¨ Hosebarb D 1¨ Hosebarb V Viton
3 30¨ (750 mm) T 1¨ Tri-Clamp T 1¨ Tri-Clamp 1
Silicone o-ring supplied
as standard without
having to specify the
‘S’ code
2
EPDM - Ethylene
Propylene Diene
Monomer Rubber
DEMICAP Capsules
ZEMT / -
Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Inlet Connection Code ǀ Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Pack N°
E 4.4¨ (113 mm) 020 0.2 µm T 1¨ Tri-Clamp T 1¨ Tri-Clamp P Pharmaceutical N Non-Sterile 3 Pack of 3
B 5.5¨ (140 mm) N 1
/2¨ NPT Male N 1
/2¨ NPT Male
A 7.9¨ (200 mm) H 1
/2¨ Hosebarb H 1
/2¨ Hosebarb
Syringe Filters
ZSMT - -
Code ǀ Diameter Code ǀ Micron Code ǀ Inlet / Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Options Code ǀ Pack N°
050 50 mm 020 0.2 µm G Stepped Hosebarb P Pharmaceutical N Non-sterile S Standard 025 25 per box
L 1
/8¨ NPT Male
Parker domnick hunter has a continuous policy of product development and although the Company
reserves the right to change specifications, it attempts to keep customers informed of any alterations.
This publication is for general information only and customers are requested to contact our Process
Filtration Sales Department for detailed information and advice on a products suitability for specific
applications. All products are sold subject to the company’s Standard conditions of sale.
12/08 Rev. 3A