Copper Conductor, PVC Insulated, PVC Inner Sheathed, Armoured & Overall PVC Outer Sheathed Cable

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

0.6/1 (1.

2) Kv

Copper conductor, PVC insulated, PVC Inner sheathed, Armoured & Overall PVC
Outer sheathed cable

Gen. Conf. to BSEN: 50288-7, AS/NZS 1125, AS/NZS 3808, AS/NZS 1660, AS/NZS 5000.3

BEFORE YOU START


1. The current ratings indicated in this Specification Sheet have been based on the calculation procedures as
recommended in IEC 60287 and the following assumptions. Rating factors should be
a. Max continuous conductor temp = °C
b. Ambient air temperature = °C
c. Ambient ground temperature = °C
d. Depth of laying = m
e. Thermal resistivity of soil = k.m/W
2. The particulars given above are nominal & are subject to normal manufacturing tolerances.
3. Sequential length marking shall be provided at every one meter on outer sheath by hot foil indenting/Printing.
4. All the drums shall be packed by PP sheet over the outermost cable layer.

PARAMETER SPECIFICATION
Annealed Bare Copper, (Conf. to AS/NZS 1125),
Conductor Material, Grade & Shape
Electrolytic, Stranded & Circular
CONSTRUCTION

Insulation Extruded, PVC-V-90 (Conf. to As/NZS 3808)


Core / Pair Identification Red, Black & Green/Yellow
Inner Sheath Black, Extruded, PVC-5V-90 (Conf. to As/NZS 3808)
Armour Galvanised Steel (Round Wire) (Single Layer)
Outer sheath Black, Extruded, PVC-5V-90

Australasian Cables (A Division of EESA Pty Ltd) 604/89, High Street, Kew 3101 Ph: 0437720513 / 0420 598 900
www.eesa.net.au / sales@eesa.net.au
500/1000 Mtrs With +/-5% Tolerance Or Single Length
Std. Packing Length in Mtrs With +/-5% Tolerance In Case Of Quantity Less Than
500/1000 Mtrs Or Balance Length
Type of Drum Wooden Drum
Overall Quantity Tolerance + 0% / - 1%
AUSTRALASIAN CORDS CABLE, Year of manufacture, No.
PACKING

of Cores & conductor size, Voltage grade shall be


Embossing/Printing provided on outer sheath of cables . Also, sequential
length marking shall be printed on outer sheath of cables
at every 1 mtr. interval.

Voltage Grade 0.6/1 (1.2) Kv


High Voltage Test 3.5 kV-rms for 5 minutes
PROPERTIES
ELECTRICAL

Permissible Voltage Variation N/A


Permissible Frequency Variation N/A
Combined Voltage & Frequency Variation N/A
Max. Conductor Temperature at Rated Current N/A
Max. Conductor Temp. at the End of Short Circuit N/A

DIMENSIONS

No. of Outer
Insulation Inner Sheath Approx. Tolerance on
No./Nom. Cross strands/Approx Armour - Sheath
(Nom. (Approx. Overall Dia. overall
Sectional Area of . Dia. of each Nom. Dia. (Nom.
Thickness) In Thickness) In Of Cable in diameter In
Conductor in Sq.mm strand In Nos. / in mm Thickness) in
mm mm mm mm
mm mm

2C X 1.5 + 1C X 1.5 As per Class -2 0.8/0.6 1 0.9 1.24 12.7 +/-2


2C X 2.5 + 1C X 2.5 As per Class -2 0.8/0.7 1 0.9 1.24 13.7 +/-2

ELECTRICAL PROPERTIES

Max. D.C Max. A.C Short Circuit


Min. Insulation Overall Shielding -
No./Nom. Cross Resistance Of Resistance Of Rating Of
Resistance at 20°C Max D.C
Sectional Area of Conductor At 20°C Conductor At 20°C Conductor
of completed Resistance of drain
Conductor in Sq.mm Phase/Earth In Phase/Earth In (Duration 1 Sec.) in
cable In MΩ/Km wire @20˚C
Ohm/Km Ohm/Km KA

2C X 1.5 + 1C X 1.5 13.6/13.6 N/A N/A N/A N/A


2C X 2.5 + 1C X 2.5 7.41/7.41 N/A N/A N/A N/A

INSTALLATION

No./Nom. Cross Sectional


Min. Insulation Resistance Constant At 20 °C / 90 °C In Gohm.m
Area of Conductor in Sq.mm

2C X 1.5 + 1C X 1.5 40/0.002

2C X 2.5 + 1C X 2.5 40/0.002

Australasian Cables (A Division of EESA Pty Ltd) 604/89, High Street, Kew 3101 Ph: 0437720513 / 0420 598 900