SIEMENS

BANY Agent

Compact Operating Instructions

BANY Agent 1
Compact Operating Instruction
Legal Information

Warning notice system

This manual contains notices you have to observe in order to ensure your personal
safety, as well as to prevent damage to property. The notices referring to your personal
safety are highlighted in the manual by safety alert symbol, notices referring only to
property damage have no safety alert symbol. These notices shown below are graded
according to the degree of danger.

DANGER
Indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING
Indicates that death ore severe personal injury may result if proper precautions are not taken.

CAUTION
With a safety alert symbol, indicates that minor personal injury can result if proper precautions
are not taken..

CAUTION

Without a safety alert symbol, indicates that property damage can result if proper precautions
are not taken..

NOTICE

Indicates that an unintended result or situation can occur if the relevant information is not taken
into account.

If more than one degree of danger is present, the warning notice representing the
highest degree of danger will be used. A notice warning of injury to persons with a safety
alert symbol may also include a warning relating to property damage.

BANY Agent 2
Compact Operating Instruction
Qualified Personal

The product/system described in this documentation may be operated only by personal


qualified for the specific task in accordance with the relevant documentation, in particular
its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable
of identifying risks and avoiding potential hazards when working with these
products/systems.

Proper use of Siemens products

Note the following:

WARNING
Siemens products may only be used for the applications described in the catalog and in the
relevant technical documentation. If products and components from other manufacturers are
used, these must be recommended or approved by Siemens. Proper transport, storage,
installation, assembly, commissioning, operation and maintenance are required to ensure that
the products operate safely and without any problem. The permissible ambient conditions must
be complied with. The information in the relevant documentation must be observed.

Trademarks

All names identified by R are registered trademarks of Siemens AG. The remaining
trademarks in this publication may be trademarks whose use by third parties for their
own purposes could violate the rights of the owner.

Disclaimer of Liability

We have reviewed the contents of this publication to ensure consistency with the
hardware and software described. Since variance cannot be precluded entirely, we
cannot guarantee full consistency. However, the information in this publication is
reviewed regularly and any necessary corrections are included in subsequent editions.

BANY Agent 3
Compact Operating Instruction
Table of contents

1 Introduction ..........................................................................................................................6
1.1 Introduction to the BANY Agent ....................................................................................6
1.2 Produktgruppe BANY Agent .........................................................................................7
1.3 Type designations .........................................................................................................7
2 Safety notes .........................................................................................................................8
2.1 Important notes on using the BANY Agent product family .............................................8
2.2 Important notes on using the device in hazardous areas.............................................10
3 Description .........................................................................................................................11
3.1 Unpacking and checking .............................................................................................11
3.2 BANY Agent components of the product .....................................................................11
3.3 Product group BANY Agent ........................................................................................12
3.3.1 BANY Agent with TAP .........................................................................................12
3.3.2 BANY Agent without TAP.....................................................................................14
3.4 Real Time Ethernet Ports TAP A, TAP B ....................................................................16
3.5 Ethernet Ports Network N1 und N2 .............................................................................17
3.6 Ethernet Ports Network P1 und P2..............................................................................17
3.7 Control Port.................................................................................................................17
3.8 USB Host ....................................................................................................................17
3.9 Micro SD Karte ...........................................................................................................18
3.9.1 Position of the Micro SD Memory Card ................................................................18
3.10 Digital I/O ....................................................................................................................19
3.11 Description of the LEDs ..............................................................................................20
3.12 The Buttom .................................................................................................................20
4 Assembling ........................................................................................................................21
4.1 Installation...................................................................................................................21
4.2 Installation options ......................................................................................................22
4.3 General installation .....................................................................................................22
4.3.1 Installation on a DIN rail .......................................................................................22
4.3.2 Installation on a standard rail ...............................................................................24
4.3.3 Wall mounting ......................................................................................................25
5 Connecting.........................................................................................................................26

BANY Agent 4
Compact Operating Instruction
5.1 Notes on commissioning .............................................................................................26
5.2 Power supply - general ...............................................................................................26
5.3 Power supply ..............................................................................................................27
5.3.1 Connecting the power supply ...............................................................................27
5.3.2 24 V DC – product group BANY Agent.................................................................28
5.4 Digital In/Outputs ........................................................................................................29
5.5 Connecting functional ground......................................................................................29
6 Technical data ...................................................................................................................30
6.1 Construction, installation and environmental conditions ..............................................30
6.2 Connectors and electrical data ....................................................................................31
6.3 Cable lengths ..............................................................................................................33
6.4 Other properties ..........................................................................................................34
7 Dimension drawings ...........................................................................................................35
7.1 BANY Agent with TAP.................................................................................................35
7.2 BANY Agent without TAP............................................................................................38
8 Approvals ...........................................................................................................................41
8.1 BANY Agent approvals, certificates.............................................................................41
8.2 BANY Agent Conformity certificates ............................................................................44
8.3 Overview of BANY Agent approvals ............................................................................45
8.4 Mechanical stability (in operation) BANY Agent ..........................................................45

BANY Agent 5
Compact Operating Instruction
1 Introduction

1.1 Introduction to the BANY Agent

Purpose of the Operating Instructions (compact)

These operating instruction (compact) contain information with you will be able to install
and connect up a device of the BANY Agent product line.

Validity of the Operating Instructions (compact)

These Operating Instructions (compact) are valid for the Product line BANY Product
group Agent.

Names of the devices in these operating instructions

Classification Description Terms used


Product line For all devices and variants of all product groups BANY
within the BANY Agent product line, the term BANY
Agent is used
Product group For all devices and variants of a product group, only Agent
the product group is used.
Device For a device, only the device name is used. BANY Agent
Variant For a variant of the device, the device name has the (-)
appropriate variant added to it in brackets (with TAP)
All variants of For all variants of the device, the device name has (-)
a device (all) added to it.

Where ca I find more detailed information on the product ?

A CD is supplied with the BANY Agent on which you will find a detailed description of the
products in PDF format in the relevant subfolder.

BANY Agent 6
Compact Operating Instruction
1.2 Produktgruppe BANY Agent

Product line Product Device (Variant) [Order number]


group
BANY Agent BANY Agent with TAP 9AE4140-1BA01
BANY Agent BANY Agent without TAP 9AE4140-1BA00

1.3 Type designations

Structure oft he type designation

The type designation of an BANY Agent is made up of several parts that have the
following meaning:

9AE4140-1BA01 BANY Agent with TAP


9AE4140-1BA02 BANY Agent without TAP

BANY Agent 7
Compact Operating Instruction
2 Safety notes

2.1 Important notes on using the BANY Agent product family

Safety notices on the use of the devices

The following safety notices must be adhered to when setting up and operating the
device and during all associated work such as installation, connecting up, replacing
devices or opening the device.

General information

WARNING
Safety extra low voltage

The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited
Power Source (LPS). (This does not apply to 100 V … 240 V devices.)

This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 /
EN60950-1 / VDE 0805-1 must be connected to the power supply terminals. The power supply
unit for the equipment power supply must comply with NEC Class 2, as described by the
National Electrical Code ® (ANSI / NFPA 70).

There is an additional requirement if devices are operated with a redundant power supply:

If the equipment is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.

WARNING
Opening the device

DO NOT OPEN WHEN ENERGIZED

General notices regarding use in hazardous areas

WARNING
Risk of explosion when connecting or disconnecting the device

EXPLOSION HAZARD

DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR


COMBUSTIBLE ATMOSPHERE IS PRESENT

BANY Agent 8
Compact Operating Instruction
WARNING
Replacing components

EXPLOSION HAZARD

SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I; DIVISION „


OR ZONE..

WARNING
Requirements for the cabinet/enclosure

When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2,


the device must be installed in a cabinet or a suitable enclosure.

Notices for use in hazardous areas according to ATEX

WARNING
Requirements for the cabinet/enclosure

To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of at
least IP54 in compliance with EN 60529.

WARNING
Suitable cables for temperatures in excess of 70 °C

In the cable or conduit entry point exceeds 70°C or the branching point of conductors exeeds
80°C, special precautions must be taken. If the equipment is operated in an air ambient in
excess of 50°C, only use cables with admitted maximum operating temperature of at least
80°C.

WARNING
Protection against transient voltage surges

Provisions shall be made to prevent the rated voltage from being exceeded by transient voltage
surges of more than 40%. This criterion is fulfilled, if supplies are derived from SELV (Safety
Extra-Low Voltage) only.

BANY Agent 9
Compact Operating Instruction
2.2 Important notes on using the device in hazardous areas

WARNING
WARNING – EXPLOSION HAZARD –

DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-


HAZARDOUS

WARNING
Restricted area of application

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-
hazardous locations only.

WARNING
Restricted area of application

This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations
only.

BANY Agent 10
Compact Operating Instruction
3 Description

3.1 Unpacking and checking

Unpacking, Checking

1. Make sure that the package is complete.


2. Check all the parts for transport damage.

WARNING
Do not use any parts that show evidence of damage !

3.2 BANY Agent components of the product

Note
When shipped, the slots for the media modules have a dummy cover fitted.

Device: Variant Plug-in terminal block Device BAK Product


BANY Digital I/O Power CD
Agent supply
BANY (with TAP) 4-pin 4-pin x x x
Agent
BANY (wthout 4-pin x x x
Agent TAP)) 2-pin
power
supply, 2-
pin digital
I/O

BANY Agent 11
Compact Operating Instruction
3.3 Product group BANY Agent

3.3.1 BANY Agent with TAP

Possible attachments

7 electrical Ethernet RJ45 jacks (with securing collar) for connection of end devices or
other network segments

1 USB Master connector

1 plug-in terminal block 4-pin for connecting the power supply and the digital in/Outputs

1 plug-in terminal block 4-pin for connecting the digital in/Outputs

BANY Agent 12
Compact Operating Instruction
Bild 1 BANY Agent mit TAP

BANY Agent 13
Compact Operating Instruction
3.3.2 BANY Agent without TAP

Possible attachments

3 electrical Ethernet RJ45 jacks (with securing collar) for connection of end devices or
other network segments

1 USB Master connector

1 plug-in terminal block 4-pin for connecting the power supply and the digital In/Outputs

BANY Agent 14
Compact Operating Instruction
BANY Agent 15
Compact Operating Instruction
3.4 Real Time Ethernet Ports TAP A, TAP B

The BANY Agent contains 2 TAPs (Test Access Points) for Fast Ethernet recording.
The RJ45 sockets A1/A2 and B1/B2 are internally connected to a TAP each.

The ethernet frames are forwarded from one TAP port to the other without delay. This also
works if the Bany Agent is powered off. It is not possible for the Bany Agent to send
packets out of the TAP ports.
Connect networks to be analyzed here. Link speed is 100 Mbit/s.
TAP A is deactivated if a cable is plugged to N1 or N2.

BANY Agent 16
Compact Operating Instruction
3.5 Ethernet Ports Network N1 und N2

These ports can be used for Fast Ethernet recording. N1 and N2 can be connected to
switch mirror ports.

3.6 Ethernet Ports Network P1 und P2

These ports are used for recording and sending Ethernet or PNIO data.
Fast Ethernet and Gigabit Ethernet is supported.

3.7 Control Port

Ctrl: RJ45 Ethernet Port


connect the Bany Agent to a PC via this port.

3.8 USB Host

The hardware contains one USB host port. Mass storage devices can be
connected here.
The standards USB 1.1 und USB 2.0 are supported.
The USB interface provide a power supply for connected devices with max. 500mA.

BANY Agent 17
Compact Operating Instruction
3.9 Micro SD Karte

At the back side of the housing there is a metal cover which can be
removed. There is a micro SD card slot behind the cover.
The standards SD and SDHC are supported with a maximum capacity of 32 GB.

3.9.1 Position of the Micro SD Memory Card

CAUTION

The Micro SD memory card is only for internal use and special debug and update
functions..
The Micro SD memory card should not be removed or inserted by the user.

In the BANY Agent, the Micro SD memory card is located behind the sealing screw on the
rear of the device. To remove the sealing screw, use a coin or a wide blade screwdriver.

BANY Agent 18
Compact Operating Instruction
3.10 Digital I/O

The hardware has 3 connectors which can be used as a digital input or a digital output.

DI/DO: digitaler Eingang oder digitaler Ausgang


SGND: Signal Masse

BANY Agent 19
Compact Operating Instruction
Eingang:

log. 0: contact open or 0V


log. 1: 24V, max. 50mA

Ausgang:

The Output can max drive 50mA.


log. 0: internal 10kOhm resistor against ground
log. 1: Output will be connected to ground by a Phototransistor

3.11 Description of the LEDs

Power (PWR): Lights up green when the power supply is connected.


Ready (RDY): Flashes green during startup, when the power is restored or after a reset,
and lights up green when the module is ready.
The module is not ready for use until the StartUP LED lights up.
Control (CTRL): Lights up green if a link to the network has been established. Flashes
orange at data exchange.
LEDs for Ethernet ports TA1/2, TB1/2, N1, N2: Lights up green if a 100MBit/s link at the
network has been detected. Flashes orange when data is received.
LEDs for Ethernet ports P1, P2: Lights up green if a 100MBit/s link at the network has
been detected. Flashes green if a 1GBit/s link has been detected. Flashes orange when
data is received.

3.12 The Buttom

There is a reset button below the USB port.


After a reset, the box is reset and switches to startup mode.
While the startup LED is flashing, the box cannot be accessed from the Web interface or via
BANY Scope.

BANY Agent 20
Compact Operating Instruction
4 Assembling

4.1 Installation

WARNING
Suitable installation location at temperatures above 50°C

If a device is operated in an ambient temperature of more than 50°C, the temperature of the
device housing may be higher than 70°C.

WARNING
Use of approved components

Use only approved components, for example supporting brackets, SFPs, 19-inch-racks
Create any supports you require according the dimension drawing

WARNING
Suitable cables for temperatures in excess of 70 °C

In the cable or conduit entry point exceeds 70°C or the branching point of conductors exceeds
80°C, special precautions must be taken. If the equipment is operated in an air ambient in
excess of 50°C, only use cables with admitted maximum operating temperature of at least
80°C.

CAUTION
Provide suitable shade to protect the Bus Analyser against direct sunlight. This avoids
unnecessary warming of the BANY Agent and prevents premature aging of the Bus Analyser
and cabling.

NOTICE

When installing and operating the device, keep to the installation instructions and safety-related
notices as described in this document and in the manual SIMATIC NET Industrial Ethernet
Twisted Pair and Fiber Optic Networks.

BANY Agent 21
Compact Operating Instruction
4.2 Installation options

Installing the BANY Agent

The BANY Agent can be installed in various ways::

Installation on a 35 mm DIN rail


Installation on a SIMATIC S7-300 standard rail
Wall mounting

For the possible types of installation, refer to the section „General Installation“ in this
document.

4.3 General installation

4.3.1 Installation on a DIN rail

CAUTION

If the BANY Agent is liable to be subjected to serve vibration (> 10 g), use an S7-300 standard
rail for installation. The DIN rail does not provide adequate support if vibration exceeds 10 g.

WARNING
When used in shipbuilding, installation on a 35 mm DIN rail is not permitted.

In ships, the 35 mm DIN rail does not provide adequate support.

Valid only for the appropriately marked devices in the various product groups. This is indicated
by a note in the installation options table. Refer to the relevant table in the section Technical
specification (subsection, construction, installation and environment).

BANY Agent 22
Compact Operating Instruction
Installation

Install the BANY Agent on a 35 mm DIN rail complying with DIN EN 50022.

1. Hang the BANY Agent on the DIN rail and then push it in against the rail until it clips
into place..
2. Fit the connectors for the power supply.
3. Fit the connectors for the digital In/Outputs.
4. Insert the terminal blocks into the sockets on the BANY Agent.

Removing

To remove an BANY Agent from the DIN rail:

1. Disconnect all cables from the BANY Agent


2. Release the lower part of the switch away from the DIN rail.

BANY Agent 23
Compact Operating Instruction
4.3.2 Installation on a standard rail

Installation on a SIMATIC S7-300 standard rail

1. Place the upper guide at the top of the BANY Agent housing in the S7 standard rail.
2. Screw the BANY Agent to the underside of the standard rail.
3. Fit the connectors for the power supply.
4. Fit the connectors for the signaling contact.
5. Insert the terminal blocks into the sockets on the BANY Agent.

Uninstalling

To remove an BANY Agent from the SIMATIC S7-300 standard rail:

1. First disconnect all connected cables.


2. Loosen the screws on the underside of the S7 standard rail and lift the BANY Agent
away from the rail.

BANY Agent 24
Compact Operating Instruction
4.3.3 Wall mounting

Wall mounting

1. For wall mounting, use suitable mounting fittings for the wall (for example, for a
concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws 3,5 mm diameter
and 40 mm long).
2. Connect the electrical cable connecting cables.
3. Fit the connectors for the digital In/Outputs.
4. Insert the terminal blocks into the sockets on the BANY Agent.

Note

For more exact dimensions, please refer to the section „Dimension drawings“.

Note

The wall mounting must be capable of supporting at least four times the weight of the BANY
Agent.

BANY Agent 25
Compact Operating Instruction
5 Connecting

5.1 Notes on commissioning

NOTICE

Commissioning devices with redundancy mechanisms.

If you use redundancy mechanisms, open the redundant path before you insert a new or
replacement device in an operational network. A bad configuration or attachment of the
Ethernet cables to incorrectly configured ports causes overload in the network and a
breakdown in communication.

5.2 Power supply - general

WARNING

You can recognize the type of power supply on a warning on the device and the labeling of the
connector to the power supply.

BANY Agent 26
Compact Operating Instruction
5.3 Power supply

5.3.1 Connecting the power supply

24 V safety extra-low voltage (SELV)

WARNING
The BANY Agent is designed for operation with Safety Extra Low Voltage (SELV). This
means that only SELV complying with IEC 60950-1 / EN60950-1 / VDE0805 can be
connected to the power supply terminals.
The power supply unit for the BANY Agent power supply must meet NEC Class 2 as
described by the National Electrical Code ® (ANSI/NFPA 70).
The power of all connected power supply units must total the equivalent of a power
source with limited power (LPS limited power source).
If the device is connected to a redundant power supply (two separate power supplies),
both power supplies must meet these requirements.
The digital In/Outputs can be subjected to a maximum load of 50 mA (safety extra-low
voltage (SELV), DC 24 V).
Never operate the device with AC voltage or DC voltage higher than 32 V DC.

CAUTION
If the BANY Agent are supplied over long 24 V power supply lines or networks, measures are
necessary to prevent interference by strong electromagnetic pulses on the supply lines. These
can result, for example, due to lightning or switching of large inductive loads.

One of the tests used to attest the immunity of devices of the BANY Agent electromagnetic
interference is the “surge immunity test” according to EN61000-4-5. This test requires
overvoltage protectionfor the power supply lines. A suitable device is, for example, the Dehn
Blitzductor VT AD 24V Art-Nr. 918 402 or comparable protective element.

Vendor: DEHN+SÖHNE GmbH+Co.KG, Postfach 1640, D-92306 Neumark, Germany.

BANY Agent 27
Compact Operating Instruction
Connecting to the supply voltage (SELV)

The power supply is connected using a 4-pin plug-in terminal block.


The power supply is connected over a high resistance with the enclosure to allow an
undergrounded set up. The two power inputs are non-floating.

Terminal block assignment (4-pin)

Pinout of the safety extra-low voltage (SELV)

Pin number Assignment (24 VDC) Labeling


DI/DO In/Output 24 V DC
SGND Ground for In/Output
M Ground power supply
L+ Power, 24 V DC

To wire up the power connector, use a copper cable of category 18 - 12 AWG or cable
with a cross-section of 0.75 to 2.5 mm².

5.3.2 24 V DC – product group BANY Agent

24 V safety extra-low voltage overview

Product group Device: (Variant) Safety extra-low voltage (SELV)

BANY Agent (mit TAP) 24 V DC


BANY Agent (ohne TAP) 24 V DC

BANY Agent 28
Compact Operating Instruction
5.4 Digital In/Outputs

The digital Inputs and Outputs are floating switches by breaking the contact.

Connecting the digital In/Outputs

The digital In/Outputs contacts are connected to a 4-pin plug-in terminal block.
The digital In/Outputs can be subjected to a maximum load of 50 mA (safety extra low
voltage SRLV 24 VDC).

Pin number Assignment (24 VDC) Labeling


DI/DO In/Output 24 V DC
SGND Ground for In/Output
SGND In/Output 24 V DC
DIDO Ground for In/Output

5.5 Connecting functional ground

Installation on a DIN rail

The device is grounded over the DIN rail.

S7 standard rail

The device is grounded over the rear panel and the neck of the screw.

Wall mounting

The device is grounded by the securing screw in the unpainted hole..

Please note that the BANY Agent must be grounded over one securing screw with
minimum resistance.

If an BANY Agent is mounted on a non-conducting base, a grounding cable must be


installed. The grounding cable is not supplied with the device. Connect the paint-free
surface of the BANY Agent to the nearest grounding point using the grounding cable.

BANY Agent 29
Compact Operating Instruction
6 Technical data

Note

Validity oft he technical specifications

All the technical specifications described in this section that is not assigned to a specific
device variant, version or a media module, apply to all devices variants/versions of the
product group.

6.1 Construction, installation and environmental conditions

Construction

BANY Agent with TAP BANY Agent without TAP


Dimension (W x H x D) 60 x 125 x 125 mm 40 x 125 x 125 mm
Weight 1 400 g 1 100 g
Degree of protection IP20 IP20

Installation options

Installation options DIN rail


S7-300 standard rail
Wall

Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ship,
the 35 mm DIN rail does not provide adequate support.

BANY Agent 30
Compact Operating Instruction
Storage/transport Operating Max. relative Max. ambient
temperature temperature humidity in temperature at
operation at 25°C operating altitude
-40°C … +70°C Horizontal installation: < 95 % (no Horizontal installation:
-40°C … +70°C condensation) Max. 65°C as of 2000m
Max. 60°C as of 3000m
Vertical installation:
-40°C … +50 °C Vertical installation:
Max. 45°C as of 2000m
Max. 40°C as of 3000m

The permitted operating temperature depends on how the mounting device was
installed. The installationis horizontal if the device labeling is from left to right. With a
vertical installation, the device labeling is rotated through 90°..

6.2 Connectors and electrical data

Connection for end devices or network components

(BANY Agent with TAP 24 V DC) 7 x RJ45-jacks with MDI-X-assignment


10/100/1000 Mbit/s (half-/full duplex)
(BANY Agent with TAP 24 V DC) 1 x USB
(BANY Agent without TAP 24 V DC) 3 x RJ45-jacks with MDI-X-assignment
10/100/1000 Mbit/s (half-/full duplex)
(BANY Agent without TAP 24 V DC) 1 x USB

Electrical data: Power supply

Device version Redundant power Redundant power Power supply


(power supply) supply unit supply possible
(BANY Agent with No No 24 V DC
TAP 24 V DC)
(BANY Agent without No No DC 24 V
TAP 24 V DC)

BANY Agent 31
Compact Operating Instruction
Electrical data: Current consumption and power loss

Device version Current consumption Effective power


(power supply) loss
(BANY Agent with TAP 24 V DC) 0,50 mA 12 W
(BANY Agent without TAP 24 V DC) 0,30 mA 7,2 W

Electrical Data: Overcurrent protection

Device version Overcurrent protectionof the power supply


(power supply) Non-replaceable fuse
(BANY Agent with TAP 24 V DC) 2 A / 32 V
(BANY Agent without TAP 24 V DC) 2 A / 32 V

Electrical data: Digital In/Output

Device version Voltage via digital Switching capacity


(power supply) In/Output (resistive load)
(BANY Agent with TAP 24 V DC) 24 V DC 50 mA
(BANY Agent without TAP 24 V DC) 24 V DC 50 mA

Electrical data: USB Port

Device version Voltage via USB Current load maximum


(power supply) port
BANY Agent with TAP (24 V DC) 5 V DC 500 mA
BANY Agent without TAP (24 V DC) 5 V DC 500 mA

Plug-in terminal block for connectors of the power supply and signaling contact

Device version Spannungsversorgung Digital Ein/Ausgänge


(power supply)
(BANY Agent with TAP 24 V 1 x 4-pin and one digital 1 x 4-pin and two digital
DC) In/Output In/Output
(BANY Agent without TAP 24 1 x 4-pin and one digital Together with the power
V DC) In/Output supply block

BANY Agent 32
Compact Operating Instruction
6.3 Cable lengths

Permitted cable lengths (copper cable – Fast Ethernet)

Cable type Accessory (Plug, Outlet, TP Cord) Permitted cable length

IE TP Torsion Cable Mit IE FC Outlet RJ45 0 … 45 m


+ 10m TP Cord + 10 m TP Cord
Mit IE FC RJ45 Plug 180 0 … 55 m
IE FC TP Marine Cable Mit IE FC Outlet RJ45 0 … 75 m
IE FC TP Trailing Cable + 10m TP Cord + 10 m TP Cord
IE FC TP Flexible Cable Mit IE FC RJ45 Plug 180 0 … 85 m

IE FC TP Standard Cable Mit IE FC Outlet RJ45 0 … 90 m


+ 10m TP Cord + 10 m TP Cord
Mit IE FC RJ45 Plug 180 0 … 100 m

Zulässige Leitungslängen (Kupferleitung – Gigabit Ethernet)

Leitungstyp Accessory (Plug, Outlet, TP Cord) Permitted cable length

IE FC Standard Cable, with IE FC RJ45 Plug 180, 0 … 90 m


4 x 2, AWG24 4x2
IE FC Flexible Cable,
4 x 2, AWG24
IE FC Standard Cable, with IE FC Outlet RJ45 0 … 90 m
4 x 2, AWG22 + 10 m TP Cord + 10 m TP Cord

IE FC Flexible Cable, with IE FC Outlet RJ45 0 … 90 m


4 x 2, AWG22 + 10 m TP Cord + 10 m TP Cord

BANY Agent 33
Compact Operating Instruction
6.4 Other properties

Mean Time between failure (MTBF)

MTBF 40 years

BANY Agent 34
Compact Operating Instruction
7 Dimension drawings

7.1 BANY Agent with TAP

BANY Agent 35
Compact Operating Instruction
BANY Agent 36
Compact Operating Instruction
BANY Agent 37
Compact Operating Instruction
7.2 BANY Agent without TAP

BANY Agent 38
Compact Operating Instruction
BANY Agent 39
Compact Operating Instruction
BANY Agent 40
Compact Operating Instruction
8 Approvals

8.1 BANY Agent approvals, certificates

Not

The specified approvals only when the corresponding mark is printed on the product. You
can check which of the following approvals have been granted for your product by the
markings on the type plate.

EC directives

SIMATIC NET products meet the requirement and aims of the following EC directives.

EMC directive (electromagnetic compatibility)

The SIMATIC NET product meets the requirement of the EC Directive:


2004/108/EG „electromagnetic compatibility“

The product is designed for use in the following areas:

Area of application Requirements

Emission Immunity

Industrial area EN 61000-6-4: 2011 EN 61000-6-2: 2005

WARNING
Personal injury and damage to property occur.

The installation of expansions that are not approved for SIMATIC NET products or their target
systems may violate the requirements and regulations for safety and electromagnetic
compatibility.

Only use expansions that are approved for the system.

BANY Agent 41
Compact Operating Instruction
-Kepp to the installation guidelines
The product meets the requirements if you adhere to the installation and safety
instructions contained in this documentation and in the following documentation when
installing and operating the product.

-You can always find the latest documentation on the Internet !


The current description of the currently available products can always be found on the
Internet under specified entry IDs/Internet pages:
SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks Manual 8763736
EMC Installation Guideline, Planning Guide 28518276

-Working on the product


To protect the product from electrostatic discharge, personnel must first discharge any
electrostatic charge from their body before touching the product.

Note
Note for the manufacturers of machines
This product is not a machine in the sense of the EC Machinery Directive. There is
therefore no declaration of conformity relating to the EC Machinery Directive
2006/42/EEC for this product.

Machinery directive

The product is a component in compliance with the EC 2006/42/EG. According to the


machinery directive, we are obliged to point out that the product described is intended
solely for installation in a machine.
Before the final product can be put into operation, it must be tested to ensure that it
confirms with the directive 2006/42/EEC.

Note
Note for the manufacturers of machines

This product is not a machine in the sense of the EC Machinery Directive. There is
therefore no declaration of conformity relating to the EC Machinery Directive
2006/42/EEC for this product.

Note for manufacturers of machines

This product is not a machine in the sense of the EC Machinery Directive. There is
therefore no declaration of conformity relating to the EC Machinery Directive
89/392/EEC for this product.

BANY Agent 42
Compact Operating Instruction
Explosion protection directive (ATEX)

The SIMATIC NET products meets the requirements of the EC directive 94/9/EC
“Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”.

WARNING
When using (installing) SIMATIC NET products in hazardous area zone 2, make absolutlely
sure that the associated conditions are adhered to:

Approval of SIMATIC/SIMATIC NET Products for Direct Installation in Ex-Zone 2“

You will find this on the Internet on the pages of Siemens Industry Automation Customer
Support under the following entry ID:

33118441 (http://support.automation.siemens.com/WW/view/de/33118441)
„Entry list“ tab > entry type „Certificates“

ATEX Code:
II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

The product meets the requirements oft he standards

EN 60079-15: 2005 (Electrical apparatus for potentially explosive atmospheres; Type of


protection „n“)
Und EN 60079-0: 2006

FM approval

The product meets the requirements of the standards

Factory Mutual Approval Standard Class Number 3611


FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Group A, B, C, D / T4 und
Non Incendive / Class I / Zone 2 / Group IIC / T4

Notice for Australia

The product meets the requirements of the AS/NZS 2064 standard (Class A).

BANY Agent 43
Compact Operating Instruction
cULus Approval for Information Technology Equipment

cULus Listed 60E9 I. T. E.


Underwriters Laboratories Inc. complying with
UL 60950-1 (Information Technology Equipment)
CSA C22.2 No. 60950-1-03

cULus Approval Hazardous Location

cULus Listed 21BP I. T. E. FOR HAZ. LOC.


Underwriters Laboratories Inc. complying with
UL 60950-1 (Information Technology Equipment)
CSA C22.2 No. 60950-1-03
UL 1604 und UL 2279
or ANSIISA 12.12.01
Approved for use in
CI. 1, Div. 2, GP. A, B, C, D, T4
CI. 1, Zone 2, GP. IIC T4

8.2 BANY Agent Conformity certificates

Declaration of Conformity

You will find the EC Declaration of Conformity for these products on the Internet at the
following address:
http://support.automation.siemens.com/WW/view/de/33118441
(http://support.automation.siemens.com/WW/view/de/33118441)

-Entry list
-Entry type „Certificates“
-Certificate type „Declaration of Conformity“

Example German: „EG-Konformitätserklärung SCALANCE X310“.


Example English: „Declaration of Conformity SCALANCE X310“.

BANY Agent 44
Compact Operating Instruction
8.3 Overview of BANY Agent approvals

Overview oft the approvales

Device: (Variant) c-UL-us c-UL-us for FM C-TICK CE ATEX95 E1


BANY Hazardous (1) Zone 2
Agent Location (1)
UL 60950 UL 1604 FM3611 AS/NZS EN EN -
1 and CI. 1, 2064 6100-6-4 60079-
CSA UL2279 Div. 2 (Class Class A, 15 : 2005,
C22.2 Nr. or GP. A, B, A) EN EN
60950 1 ANSI/ISA C, D, T.. 61000-6-2 60079-0 :
12.12.01 2006
CI. 1, II 3 G Ex
CSA C22.2 Zone 2, nA II T..
No. 213- GP. KEMA 07
M1987 IIC.T.. ATEX
0145X
CI. 1, Zone CI. 1,
2, GP. IIC, Zone 2,
T.. GP. IIC,
T..
with TAP (-) X - - - X - -
without (-) X - - - x - -
TAP

1)
For temperature information “T..” or the maximum ambient temperature “Ta:..”), refer to
the type plate.

Note
Shipbuilding approval
No applications for shipbuilding approvals will be made for the BANY Agent

8.4 Mechanical stability (in operation) BANY Agent

Device: (Variant) IEC 60068-2-6 vibration IEC 60068-2-27 shock


5 – 9 Hz: 3,5mm 15 g, 11 ms duration
9 – 150 Hz: 1g 6 shocks per axis
1 octace/min, 20 Sweeps
BANY Agent (with x x
TAP)
BANY Agent (without x x
TAP)

BANY Agent 45
Compact Operating Instruction
BANY Agent 46
Compact Operating Instruction