U.C.

ME
OPC

TM

Alert-Analyze-Act
Immediate Control. Anytime. Anywhere.

Alarm Notication

Remote Control

Alarm Analysis

OPC Scheduling

U.C.ME-OPC - Software for superior industrial automation control.


Using standard wireline, wireless, and SMS technologies, U.C.ME-OPC interfaces with any SCADA/HMI, OPC or DDE server to provide efcient, rapid and secure two-way communication with SCADA platforms, remote devices and users, via text messaging (SMS) or telephony.

U.C.ME-OPC - Combining four advanced functions to keep you covered


Alarm Notication
Via multiple channels
U.C.ME-OPC is advanced alarm notication software that can send alarms in a number of ways: Voice over Telephony - send a voice message via phone. U.C.ME-OPC can concurrently dial to four recipients. During the call, alarms may be acknowledged; tag values may be retrieved or changed by the recipients. SMS - send a text message to any phone using cellular or landline modems. Pager - send a text message to a pager using an analog modem. Email - send a text message using email. Fax - send a text message to any fax. Voice annunciation - play a message over the computers speakers.

Remote Control

For rapid response


With U.C.ME-OPC, users can respond instantly to alarms via phone or SMS messaging. Predened SMS templates stored in the users cell phones can be used to change set-points, query eld values, suspend or resume alarm notication and more.

Alarm Analysis
More than simply notication
U.C.ME-OPC analyses the critical parameter data of an alarm, compares the values with the desired range, and marks the parameters that dont comply. This real-time information is sent directly to your cell phone, pager or email so you can take rapid action, and is also stored in a database for ofine analysis.

OPC Scheduling
Event notication - Any time, any day.
Schedule pre congured event notication scenarios based on time, day or date. Assign OPC tag values based on time and date.

How can U.C.ME-OPC benet you?


Remote control - Innovative capability enables exible two-way communication for shortened response time and unprecedented efciency. Sophisticated escalation procedure - Escalation procedure can be customized to ensure alarms are delivered to alternative recipients. Remote alarm acknowledgement prevents unnecessary repeat alarm notications reducing nuisance alarms and reducing costs. Detailed, real-time alarm analysis - By providing additional plant oor parameters, U.C.ME-OPC provides you with more, detailed information so you can have the complete picture at the moment of an alarm for a more accurate response. Easy alarm import from your SCADA - Saves the time and effort of manually redening your alarms in U.C.ME-OPC. Reliability & Security - U.C.ME-OPC is active even when you are not logged in. The system automatically reconnects after a power outage or after an OPC server software has stopped. 21-CFR-Part 11 compliance - Supports FDA regulations, assisting pharmaceutical and food factories with compliance.

More U.C.ME-OPC Features


Runs as a Microsoft Windows service The service operates before a user has logged in and continues to operate after the user has logged off. If the service fails, recovery actions can be set up, such as restarting the service automatically or restarting the computer (for computers running Windows 2000, XP and Windows 7 only). Multiple server connectivity - U.C.ME-OPC communicates with multiple OPC servers and with industrial automation software (SCADA) via OPC or DDE. Shifts and special days - Recipients are notied according to predened shift schedules; recipients may also specify special days such as holidays in which the shift priorities are different from the regular week. Log function - Records all alarms, responses and other activities, while alarm history may be viewed and analyzed on any computer via Internet/Intranet. This feature ensures a complete and thorough monitoring of every activity for enhanced efciency and exibility. Recipient groups - Alarms can be sent to pre-dened groups, for a more efcient notication system and easier alarm maintenance.
Recipients can take corrective action remotely by sending a text message to U.C.ME-OPC.

1
A critical device is faulty or a critical value exceeds its limits.

U.C.ME
OPC
U.C.ME-OPC sends a text message (SMS) to the recipients' cell phones.

TM

!
2

The alarm is detected and generated by U.C.ME-OPC.

Advanced Options
Cell-phone active alarm window - One click on a predened link on the cell-phone browser will open a GPRS link straight to an active alarms window; users may also choose not to receive alarm notication, and instead browse this window periodically. Server watchdog mechanism - UCME-OPC runs a watchdog mechanism with the OPC or DDE server software. When the server (SCADA) is not operating, UCME-OPC will notify the appropriate users. Master/Standby - U.C.ME-OPC supports master/standby conguration. U.C.ME-OPC running on the standby PC will send alarms only as backup to U.C.ME-OPC at the master PC.

Design: www.tween-id.com

U.C.ME-OPC - Versatility, Flexibility


er Voice ov ny Telepho SMS Voice ation annunci Email Fax Pager

No matter where you are, you can utilize U.C.ME-OPCs remote bidirectional control functionality via multiple channels for real time monitoring and control of remote sites, and quick response.

U.C.ME-OPC Applied

Making your Field a more Convenient Place to Work U.C.ME-OPC is the ideal solution for a wide range of elds, including: Building management Oil and gas works Power stations Water works and sewage treatment plants Factories and production lines Fire detection control systems Healthcare Food and pharmaceuticals And more

Specications

Hardware requirements Intel Pentium4 or higher Dialogic telephony (or telephony and fax) board or Way2Call Hi-Phone USB device (if voice phone calls are required) Approved CDMA or GSM cellular modem or landline SMS modem Available PCI slot (when using Dialogic telephony board) Available serial port (external modem) Available USB port (for the Hi-Phone telephony device) and for the U.C.ME-OPC security dongle

Supported Software
The following software packages have been tested and are supported by Control-See's U.C.ME-OPC software: GE Fanuc iFix and Cimplicity, Ci Technologies CiTect, Control Microsystems ClearSCADA, Wonderware InTouch, KEP Inlink ,National Instruments Lookout, ARC Info PCVue, OSIsoft PI, Rockwell RSView, Siemens WinCC, ELUTIONS Wizcon, Emerson DeltaV.

U.C.ME-OPC is 3rd Party Certied!


Independent Test Lab OPC Certication is the process of ensuring that applications meet the standards specied by the OPC Foundation. OPC Certication requires extensive testing to ensure true interoperability. OPC Certication means multi-vendor system interoperability is guaranteed. If your OPC products are not certied, you need to ask your vendor what sort of guarantees they offer.

Software requirements
Windows 2003/2008 Server (32 and 64 bit), Windows XP, Windows Vista, Windows 7 (32 and 64 bit) OPC or DDE server software, or SCADA/HMI software that supports OPC or DDE server functionality

U.C.ME-OPC is at your serviceWe welcome enquiries and would be happy to discuss how U.C.ME-OPC can help you.