Weebill Lab User Guide - en
Weebill Lab User Guide - en
Weebill Lab User Guide - en
Charging Procedure·······································································4
■ Installation
Tripod Installation··········································································5
■ Balance Adjustment
Balance Adjustment······································································8
■ How to Use
Buttons Description·······································································10
■ APP Operations
Image Transmission System and APP Operations························18
Initialization Method····································································20
Six-side Calibration········································································21
Motor Fine-tuning·········································································22
■ Product Specifications
Warnings························································································24
■ Warranty Card
Warranty Period············································································28
Exceptions······················································································28
The product package comes with the following items. In case that any item is
found missing, please contact ZHIYUN or your local selling agent.
USB Cable
Type-C Adapter × 1 Storage Case × 1
Storage Box × 1
1
Get to Know WEEBILL LAB
1
2
3
4
5 14
15
6
7 16
17
8
18
9
19
10 20
11 21
12 22
13
2
Preparing and Charging the Batteries
When using WEEBILL LAB for the first time, please fully charge and activate
the batteries with the dedicated charging device contained in the package to
ensure normal use of the product.
When the batteries are not in use, please be sure to put them in the
battery slot of the package or in plastic storage cases (the storage case
needs to be purchased separately).
3
Preparing and Charging the Batteries
Charging Procedure
1. Insert the batteries into the charger in the right direction (positive/negative
end) accordingly.
2. Connect the charger to the adapter via the Micro USB cable.
3. Plug the adapter into an USB power outlet to start charging.
1. Battery charging may fail when the power supply is insufficient (for
instance, when the current of the adapter is lower than 500mA).
Conditions may vary depending on the specific chargers used. It is
recommended to use an adapter with higher current capacity.
2. The battery cannot be charged through the USB port on the stabilizer.
4
Installation
Each axis of the gimbal is equipped with a latch. You can use these latches to
lock the axes for convenient installation and storage.
Tripod Installation
Get the tripod ready and mount it to the 1/4"-3/8" threaded hole at the
bottom of the stabilizer, then unfold the tripod on a flat surface.
You can also install the tripod onto the base of battery compartment to enter
Sling Mode.
Be sure to put the tripod lock switch to lock position before entering into
Sling Mode.
5
Installation
Battery Installation
Camera Installation
a. Take out the quick release plate module and press the Quick Release Button
to take out the Arca quick release plate.
b. Mount the camera on the backing base as above, then mount it on the
quick release plate and tighten the 1/4’’ screw at its bottom.
c. Adjust the lens support on the quick release plate to support the lens and
ensure it is stable.
d. Mount the installed quick release plate into the quick release module, and
then install and lock the whole module on the three-axis stabilizer.
6
Installation
Connect the two ends of the camera control cable included in the package to
the control interface of the camera and stabilizer.
1. If the camera uses type-c interface control, please connect with the
type-c adapter included in the package.
2. The list above is based on Sony a6300 and Panasonic GH5. For
compatibility with other cameras, please refer to our official website or
consult customer service.
3. Please charge the camera through the camera control interface. If
your camera has sufficient power and does not require direct charging
with the stabilizer, please turn off the USB power supply option of the
camera to save power of the stabilizer.
7
Balance Adjustment
Balance Adjustment
8
Balance Adjustment
Before turning on the stabilizer, make sure the three motors are unlocked
and can move freely. Turning on the stabilizer in locked state will lead to
overheating and damage of the motors.
9
How to Use
Buttons Description
*When the stabilizer is properly installed with the follow focus CMF-04 (needs
to be purchased separately), the focus or zoom control function can be
achieved by installing the gear ring on either the focus or zoom channel of the
lens. WEEBILL LAB does not support synchronous zoom & focus control.
10
How to Use
Joystick
Four-way direction control of the camera / lens on the stabilizer.
Video [ ]
Single press to start/end video recording.
LV Button [ ]
11
How to Use
Icon Description :
Video Mode
Photo Mode
Locking Mode
Following Mode
PhoneGo Mode
Vortex Mode
Aperture Value
ISO
EV
12
How to Use
"1" AB point settings are only available when connecting to ZHIYUN Servo
Follow Focus correctly.
13
How to Use
The motor torque of the stabilizer shall be adjusted by 3 levels to adapt to the
specific camera and lens applied for ideal performance.
How to adjust :
Weight
Motor Force Examples of Compatible Camera & Lens
Capacity
low Low Sony rx 100 series or pocket camera
medium
Medium Sony A6500+FE35 f2.8
(default)
high High Sony A7R3+FE24-70 f4
Either the motor force is set too high or too low (unmatched with weight
capacity) can lead to camera shake and affect normal use of the stabilizer.
14
How to Use
Motors circled in red will auto move with the stabilizer, while motors
circled in grey are locked instead of moving with the stabilizer.
The camera pans left/right following This mode locks the movement of
the movement of the stabilizer while all three axes to keep the camera
the tilt and roll axes are locked. Push fixed on a shooting direction. Push
the joystick up/down allows manual the joystick up/down and left/right
control of the tilt axis. allows manual control of the tilt axis
and pan axis.
This mode allows the camera to The camera pans and tilts following
roll left/right at a Max. angle of the movement of the stabilizer. Push
45° and all the three motors with the joystick left/right allows manual
unlimited 360° rotation following control of the roll axis.
the movement of the stabilizer.
15
How to Use
Tilt Axis
Tilt Axis
Roll Axis
Roll Axis
The camera pans left/right and tilts The camera tilts with a 90° angle
up/down following the movement following the movement of the
of the stabilizer in faster speed while handle while the roll axis is locked.
the roll axis is locked. Please use this mode in an underslung
gesture and push the joystick right/left
to rotate the pan axis.
Before using with Sling Mode, please be sure to put the tripod lock switch
to lock.
16
How to Use
Under pan following mode and locking mode, you can manually rotate the
camera to a certain angle, then loosen your grip and the camera position will
be fixed. Under pan following mode, you can manually adjust the angle of tilt
axis. Under locking mode, you can manually adjust the angle of pan axis and
tilt axis.
17
APP Operations
Download APP
Scan the left QR code (Android 5.0 and above, IOS 9.0
and above) or search "ZY Play" directly in the app
store to download "ZY Play".
18
APP Operations
1. Power on the stabilizer and connect the stabilizer with the camera with the
corresponding camera control cable. Turn on Bluetooth and WIFI on the
mobile device.
2. Open "ZY Play" and select the product page corresponding to WEEBILL
LAB. Click "connect device", and select the stabilizer with the corresponding
Bluetooth name (the Bluetooth name WEEBILL LAB_XXXX can be viewed in
About).
3. After entering the APP's main interface, tap the WIFI icon [ ] and connect
to the stabilizer WIFI according to the prompts (Initial default password
12345678).
Stabilizer Parameters
Panorama
Settings
19
Calibration and Firmware Upgrade
Initialization Method
20
Calibration and Firmware Upgrade
Six-side Calibration
1. Power on the stabilizer and enter standby mode, then press menu and
rotate the dial to "calibration" option. Press right to confirm selection.
2. As seen below, conduct six-side calibration following the 6 steps shown in
the graphs, finish by pressing any button to exit the menu.
STEP 1 STEP 2
STEP 3 STEP 4
21