EL-1200 Brochure
EL-1200 Brochure
EL-1200 Brochure
Sterilisation
Disinfecting
Water
purification
© 2009. The written and pictorial material in this document is the property of
Envirolyte Industries International Ltd and its partners and may not be copied,
disseminated or reproduced in any form without the written permission of Envirolyte
Industries International Ltd.
On-site production of solutions for cleaning, disinfecting and sterilizing
EL-1200
The units electrolyze the salt water and, using polymer or ceramic membranes, separate the
positive and negative ions. As a result of these electrochemical reactions various types of
activated solutions are produced. The purpose is to control and/or eliminate pathogens such
as bacteria, viruses, spores, mold and fungi, as well as cleaning and removing heavy metals.
Key Features
EL-1200
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
• A flow controller is installed in the Hydraulic part to shut
the Envirolyte unit if there is interruption of water supply
and to start the unit as soon as water flow resumes.
• A simple on/off switch with power indicator starts and
stops the ELA units manually.
• Capacity depends on the model and varies between 40
LPH and 4000 LPH
EL-1200
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
The Envirolyte Solutions
ANK-Neutral Anolyte solution is used wherever pH is important (e.g. corrosion) and where
possible evaporation of active chlorine cannot be avoided. Neutral Anolyte is highly effective
against a broad range of pathogens including bacteria, viruses, spores, mold and fungi.
Acidic Anolyte solution can be used wherever there is a need to disinfect or sterilize in
applications where the pH is unimportant and where there is no danger of corrosion. Acidic
Anolyte is a very powerful and fast acting disinfectant against all bacteria, viruses, spores,
mold, fungi and algae even when it is diluted in water or sprayed in the air.
Catholyte Solution is alkaline and serves as an excellent washing liquid, plus it removes
heavy metals from water through precipitation.
Every Envirolyte unit can be set to generate either ANK- Neutral Anolyte only with
isolation of a certain volume of Catholyte for Ph correction of ANK or Acidic Anolyte
and Catholyte only. Setting of the unit for production of specific fluids is done at the
Envirolyte factory
Producing Solutions
Typically, Anolyte produced by an Envirolyte unit is collected in a container and then dosed
into the incoming water. The dosing regime depends on the water flow and quality (properties)
of the water and is controlled by a flow meter connected with a dosing pump. The units can
stand alone (e.g. for spraying, hand cleaning, CIP disinfection, etc.) or they can be used as
part of a continuous process in more complex systems. Design facilities are available for
customized units.
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
-Can be safely disposed of in sewage systems
-Are fast-acting;
-Can be used in all stages of disinfection and cleaning;
-At recommended concentrations, do not bleach surfaces or materials;
-Can be applied in liquid, ice or aerosol (fog) form;
-Are hypoallergenic;
-Yield by-products that are non-toxic, environmentally friendly and leave no synthetic
chemical residue;
-Can be generated on-site, thus eliminating handling and storage of chemicals;
-Can be produced on-site from tap water and salt in required quantities and
concentrations of active ingredients, pH and salinity (mineralization).
This layout would be used when the disinfectant fluid (Anolyte) and the cleaning fluid
(Catholyte) are required as separate liquids. This configuration is often used in applications
such as surface cleaning where the Catholyte is added to warm water to facilitate its degrease
action. The generator is connected to a level sensor in the first buffer tank and it will start
or stop depending on the levels set at installation. Pumps can be connected to the tanks to
move the fluids either into a water system or to connect to high pressure sprayers or fogging
equipment for surface cleaning. In addition in the waste water industry Catholyte and Anolyte
are often required as separate fluids.
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
Water Systems
Health Care/Medical
Veterinary
Poultry Industry
• General disinfection
• Surface cleaning and misting medium for aerobic and
anaerobic bacteria
• Fodder assimilation
• Promotion of general health as a drinking water additive
(reduced mortality)
• Pest control on feathers (lice)
• De feathering, aerobic and anaerobic bacteria control through
misting
• Equipment cleaning without further additives.
• Disease control and cure
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
Pig Farming
• General disinfection
• Surface cleaning and misting medium for aerobic and
anaerobic bacteria
• Fodder assimilation
• Promotion of general health as a drinking water additive
(reduced mortality)
• Pest control on the skin.
• Aerobic and anaerobic bacteria control through misting
• Equipment cleaning without further additives
• Disease control and cure
Dairy Farming
• General disinfection
• Surface cleaning and misting medium for aerobic and
anaerobic bacteria
• Fodder assimilation
• Promotion of general health as a drinking water additive
(reduced mortality)
• Pest control on the skin.
• Aerobic and anaerobic bacteria control through misting
• Equipment cleaning without further additives
• Disease control and cure
Horticulture/Agriculture
Waste Water
Cooling Towers
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.
Breweries
Food Processing
Swimming Pools
• Effective biocide
• Does not irritate eyes and skin
• Does not have such sharp chlorine smell as other chemical
products
• Does not irritate airway
• Does not cause allergy
• Easy to use and handle - it is prepared on site and on demand
• Cheap (1m³ of ANK Anolyte cost about €1.9)
envirolyte@envirolyte.com
www.envirolyte.com
© 2009. The written and pictorial material in this document is the property of Envirolyte
Industries International Ltd and its partners and may not be copied, disseminated or reproduced
in any form without the written permission of Envirolyte Industries International Ltd.