Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
85 views26 pages

A0204-2A Ultrasound 7D HIFU Machine Vaginal Tightening

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 26

TWO IN ONE

(7D+Privacy+Detection function)

Before using the instrument, please read the manual carefully and operate

the instrument strictly in accordance with the instructions in the manual.


Preface
Dear users:

Welcome to use our latest product of 7D multi-line ultrasonic


Beauty Machine (7D+Private ultrasound+Detection function).Name:

two in one,Two in one is a multi-row fixed-point + 360 ° degree

dead-angle technology.
The 7D multi line ultrasonic beauty machine is a more

authoritative and higher end anti aging system instrument after the

continuous Thermage Ultrasonic Beauty Machine.This technique has

no bleeding, no surgery, no scars, no trauma, and replaces various

effects of traditional facial anti aging wrinkle surgery including

face lifting, removing double chin, lifting firmness, wrinkles,

tightening the skin, etc. It completely solve the problem of aging and

sagging on the face and body parts, and recreate the contours to

restore the youth!Compared with previous single-line technology

effects is more durable.

Privacy is a more authoritative and high-end private anti-aging

instrument after private laser. This technology has no bleeding, no knife,

no scar, no trauma and high safety. It is aimed at solving the problems of

female vaginal tissue rupture, damage, dryness, relaxation and so on.

Instrument Overview
Our new latest product two in one beauty instrument can achieve

four perfect effects of skin tightening, wrinkle removal, shaping

body,Tighten pudendum.The most advanced part of the two in one

beauty instrument is the use of the most advanced ultrasonic energy,

which can penetrate deep into the SMAS layer of the skin, causing

immediate contraction of collagen and stimulating collagen fiber

network, thus enhancing skin elasticity from the bottom layer (the

self-repair mechanism is safer).This is the safest and most effective way

to treat facial skin aging and sagging and Vaginal relaxation in the beauty

industry. two in one beauty instrument ,the magical removing wrinkles

lifting and Vaginal tightening efficacy has been recognized by the

authoritative institutions in the beauty industry, and is known as the

miracle of youthful youth!

Combining 7D with privacy can not only tighten the face, eliminate

wrinkles and resist aging, but also tighten the female's privacy. That is,

the facial rejuvenation, but also has a girl-like private compact tender
slippery, an instrument, double choice.
Instrument Principle

The two-in-one instrument uses high-energy focused ultrasound to

penetrate and produce nearly 10,000 coagulation points in deep layer of

skin, which acts on SMAS fascia layer in deep layer of skin, causes collagen

to contract immediately, stimulates collagen regeneration and

reorganization, and constructs a new collagen fibre network to enhance


skin elasticity from the bottom of skin.

The two-in-one instrument uses probes of different depths (1.5mm,

2.0mm, 3.0mm, 4.5mm, 6.0mm, 9.0mm, 13.0mm ) to accurately focus

energy on the epidermis, fascia and collagen layer; 4.5mm is located in

the subcutaneous fascia layer, which produces protein coagulation

reaction, thus producing tension around the coagulation point as the

center and exerts tension on the fascia. Muscle layers grow and pull to

achieve the best effect of shaping, lifting and tightening; 3.0mm acts

on subcutaneous collagen layer to stimulate collagen regeneration,

which can gradually tighten and improve skin and restore elasticity;

facial wrinkles caused by sagging; one operation, comprehensive

facial synthesis Pull up and tighten the whole contour.

Privacy is the use of different depths (3.0mm, 4.5mm) of the treatment

head, the precise energy focused on the vaginal collagen layer, fascia layer,

the use of machinery to produce about 60 degrees to 70 degrees of

thermal effect, promote the vaginal deep mucosal collagen fiber

regeneration and fascia contraction, increase the production of new

tender tissue, change. Vagina is dry and astringent, which promotes

vaginal mucus secretion during sexual intercourse, and ensures vaginal

moisture and tenderness. Mainly for vaginal tissue rupture, damage,

dryness, urinary incontinence, relaxation and other issues for

comprehensive treatment, triggering the body to start the repair of

regenerative cells. Finally, the purpose of alleviating and solving vaginal

relaxation is achieved.
Because the energy is Skiming over the epidermis, there is no need to
worry about the injury of the mucosal layer and the infection caused by

the injury of the sensory mucosal layer. Private functional instruments

extend the probe into the vagina through the operator, and uniformly act

54-216 lines (about 1350-5400 points) in the SMAS layer of the vagina to
achieve the best effect of vaginal contraction.

Technology Advantage

1 .Two modes for 7D :manual mode or auto mode can be switched.


2 .7D: the corresponding parameters can be adjusted according to

the size of the skin area,which make the operation time is greatly

shortened , make the energy point effects on the skin is more uniform,

and the curative effect is better.

3 .7D Using the most advanced high-tech technology, it is equipped

with two treatment heads according to the facial skin condition,which

accurately affects different depths of skin,and the energy is slightly over

the epidermis during treatment, and 100% without any damage.at the

same time,the depth of the skin treated by the treatment head is

consistent with the set value, ensuring the customer's painless and

comfortable.

4 .In addition to the thermal effect on dermal collagen and collagen

fiber, it also has thermal stimulation on the fat layer and fascia layer

(SMAS), and the therapeutic effect is far better than that of Thermage.

5 .The operation is simple and convenient, no need for consumables,

greatly reducing treatment costs.


6 .The effect of tightening and shaping can be seen immediately after

treatment, which can last for at least 18-24 months at a time, and achieve

negative growth for skin age once a year.

7.Makeup immediately after treatment does not affect normal life and

work.

8 . privacy use of 360 degrees of 3D surround technology, through

automatic control of rotation angle, to ensure that multiple accurate,

uniform dots, good results.

9.The energy is controllable,and the corresponding parameters can be

adjusted according to the depth of the vagina, so the operation is safer

and more secure.

10 .Safe and non-invasive: non-invasive stimulation of deep collagen

and elastic fiber proliferation, treatment energy slightly over the mucosal

layer, 100% without any damage, to ensure customer comfort and

pain-free.

11 .Immediate tighten was achieved after operation.

12 .One week after treatment,it can resume normal sexual life.

13 . High safety: It is safe and effective after high-end technology

approval and clinical trials, and will not have any impact on natural

childbirth.
Name of instrument parts

Functional profile of the treatment head

Facial functional The depth of skin treatment and efficacy

Energy reaches directly to the dermis layer, making the

1.5mm fibrous tissue densely arranged to make the skin

smooth and delicate.

Energy directly to the skin subcutaneous tissue


3.0mm accelerates the activity of cell, regenerating collagen to

increase skin elasticity and firm skin.


Energy directly reaches the fascia layer to thermally

coagulate the fascia layer, which produces the effect of

tightening and lifting the fascia layer to suspend the


4.5mm skin, so that the skin can be improved from deep to

shallow to support the subcutaneous structure of the

skin, and better help the bottom layer of the skin to

restore elasticity and remove the wrinkle to lift facial

skin.
Energy goes directly to submucosal tissue to accelerate
privacy3.0mm
cell activity, regenerate collagen, increase mucosal

elasticity and tighten vaginal muscles.

The energy goes directly to the fascia layer, which makes

the fascia layer heat coagulate to produce the effect of


privacy4.5mm
tightening Yin.Improve the muscle structure supporting

the mucosa from deep to shallow to help the muscle

layer restore more elasticity and compactness.

Privacy testing tube Using the principle of balloon manometry to detect

vaginal relaxation.
The instrument is equipped with four probes: 7D head: 1.5mm, 2.0mm, 3.0mm,
4.5m, 6.0mm, 9.0mm, 13.0mm, Privacy head: 3.0mm, 4.5mm.
Installation of Instruments

First: insert the 7D handle line into the right socket of the machine and

fix the screw.

Second: insert the private handle line into the left socket of the

machine; (align the hole position and install, lock the handle again)

Thirdly: the power cord is inserted into the back power socket and

connected to the power supply line suitable for the voltage in the normal

working range of the instrument.

The images of the 7D probe is shown below


Interface introduction
1 . Start-up

Check whether the connection of the instrument is normal,switch on

the power of the instrument and press the power switch of the host, the

machine will start up and the boot interface appears.

Operation interface for 7D

According to different treatment areas , choose suitable size probe to do

the treatment .
2 .Function introduction of professional work interface.

Various parameters can be adjusted in the working interface as

following:

Choose the mode of 【manual】 or 【auto】 according to treatment request.

【Remain】represents the number of shots remaining on the probe;

【Total】represents the total number of shots on the probe;

【Line】represents the number of lines in one shot;

【Length(mm)】represents the total length of the energy region of the

ultrasonic beauty instrument;

【Power(J)】representsenergy;click【-】(decrease)
【+】(increase)
【 F 】 represents the interface of face;

【 B 】 represents the interface of body;

Click【Start】the instrument star to work;

Click【Pause】the instrument stops working;

and then click【SAVE】Save parameter storage;click【Back】represents return

The usage range and operation parameters of 7D probes are recommended

8-11mm 【Power】:
【Length】: 1.3-1.8 j

1.5mm probe :Neck / double chin / jaw /

cheek / forehead 0.4J


【Power(J)】:

2.0mm probe :Around the eyes 0.4J


【Power(J)】:

3.0mm probe:Neck / double chin / jaw / cheek 【Power(J)】:0.6J

4.5mm probe:Neck / double chin / jaw / cheek 【Power(J)】:0.6J

6.0mm probe :chest 【Power(J)】:0.8J

8.0mm probe :Abdomen 【Power(J)】:1.0J

10.0mm probe :hand / leg 【Power(J)】:1.0J

13.0 mm probe :hand / leg 【Power(J)】:1.2 J

16.0 mm probe :hand / leg 【Power(J)】:1.2J


3 .Introduction of Privacy Operating Interface:
NOTE:Click ready after the preparation is successful,the handle lamp will
be on, and then press start.

Optional probe : 3.0mm, 4.5mm


4 .Introduce the testing interface:

Click on the detection function to enter the detection interface

Save the value of tightness Value of instant tightness

① Clean and disinfect the balloon head of the test tube and put a

condom on the balloon;

②Please put the head of the balloon into the vaginal (for example, if

it is difficult to put it in, lubricant can be added)

③Before measuring, please keep your body lying down, legs standing

naturally, legs differentiated but not more than shoulder width, In

the measurements, the circular and pelvic floor muscles of the vaginal

were contracted forcefully to observe the values on the screen, and the

highest values were recorded. The vaginal was clamped and measured in

the form of urine suffocation,


(Do not contract buttocks and thigh muscles to avoid affecting the

accuracy of measurement).

④ After 6 seconds of relaxation, breathe naturally and enter the first

measurement, totaling 2 measurements.


(The first measurement is the standard value of your privacy relaxation

before the instrument is operated)

(The second measurement is the standard value of your personal

tightness after the instrument is operated)

⑤Correspond to the following values of the vaginal elasticity test table

in order to determine the exercise method.

Pressure value Relaxedstate Degree of Suggested Exercise Ways


sensitivity
60 below Very poor No Must Strengthen Exercise
60-80n Relatively poor Low Need to keep exercising
80-120n normal General Need moderate exercise
120-160n Better flatus Exercise in ascension
vaginalis
More than 160 excellent goddess Maintenance Exercise

⑥After measuring, take out the probe clean, dry the soft cloth and put
it in the packing box for next use.

Airbag head

Privacy Testing Tube


Various parameters can be adjusted in the working interface as

following:

【Remain】represents the number of shots remaining on the probe;

【Total】represents the total number of shots on the probe;

【Round】represents the total rotation angle of the cartridge in a circle;

【Angle】represents the single rotation angle of the cartridge in a circle;

【Length(mm)】represents the total length of the energy region of the

ultrasonic beauty instrument;

【Pitch】represents the distance between points;

【Power(J)】representsenergy; click【-】(decrease)
【+】(increase)
Click【Start】the instrument star to work;

Click【Pause】the instrument stops working;

Instrument instructions
1 Operation introduction for 7D
⑴ Clean face→ Before the operation of the instrument, the gel should be

evenly applied to the part to be treated.

⑵ Face : Firstly, the 4.5mm probe is operated, then the 3.0mm probe

(synchronizing the position of 4.5 probe) is operated, and finally the

1.5mm probe is operated. (All probe operations range from deep to

shallow)

⑶ Before the operation of the instrument, replace the required

treatment head and adjust the energy from low to high to the range that

the experiencer can withstand.

⑷ 7D manipulation : operate with this line position (as shown below)

- 7D whole facial operation:each depth probe operates 200-250 rounds;

Area C: Ultra-thin skin around the eyes, using a


1.5mm subcutaneous ultrasound knife probe
7D Operational exclusion zone :Avoid hairline, temples, eyes (eyeballs),

Yintang, nose,Around the mouth ,Lip, chin, Mandible ,larynx, aorta, and

Where nerves such as navel pass through;

The thyroid around the neck can not be operated;When treating the body,

where nerves pass and blood vessels pass, please do not operate.

⑸ During the operation, the treatment head should be kept flat against

the skin, and the operation spacing should be arranged closely.

⑹ In the process of operation, we should constantly ask the experiencer


about comfort and adjustment of energy size to ensure that the
experiencer receives the experience in a pleasant state.
⑺ Repeated intensive treatment at the problem site (2-3 times).

⑻ During operation, please keep the skin moist. If the coated medium
dries out, you need to re apply the gel.
⑼ Postoperative Repair Nutrition--Cellular food and collagen were

taken uninterruptedly for 1 to 6 months,according to the condition of


skin rehabilitation.

⑽ Such as: teeth or around the teeth, implant teeth, there may be

toothache.it can be done by inhaling to make the mouth bulge up or


wrapping the teeth with gauze at this time.

⑾ 7D treatment reference:
Problemati Severe skin
Width Clearance Power Pitch Lenght
c skin
Normal 1 times /2-3
skin
8-11 1.5-2.0 0.4-1.2 1.3-1.8 05~25 Three months
times as a
Sensitive
5-11 1.8-3.0 0.3-1.0 1.5-2.0 05~25 course of 5 times as a
skin treatment course of
treatment
2 Introduction to Privacy Operations
Preoperative preparation is required :Gel Lodophor cotton ball Normal

saline 75% Disinfectant Alcohol Lubricating oil Condom Medical cotton

swab and gauze Disposable gloves and masks.

⑴ Keep skin and pubic hair clean before operation;Clean vagina,To

prevent dirt from entering the skin with ultrasound or to prevent the
penetration of ultrasound.
(2) Before use machine,Sterilize the handle and wipe it dry;When the
probe is installed on the handle,the corresponding parameters of the
probe will be displayed on the screen.

⑶ First clean the treatment area,use iodophor disinfection to wipe the


inner vulva, and normal saline to clean and wipe the outer vulva.
⑷ Vaginal relaxation was measured with a test tube before operation,Put

a protective cover (condom) on the balloon head of the test tube and put
it into the vagina for detection.The instrument was used to measure the
tightness after vaginal treatment.

⑸ If automatic mode is required,click "AUTO". AUTO key highlights


represent automatic mode.
⑹ The gel is applied to the probe energy emitter (probe black film domain).
Note: gel can be added more.

⑺ Put a condom on the probe.


(e.g. if it is difficult to insert,a layer of Lubricant product can be applied on
the outer surface of condom)

⑻ After clicking Ready to prepare key, the handle rotates 360°,and the
automatic rotation reset lamp of the handle turns on.Click on the "Start"
button to enter the working state.

⑼ Probe operation process:probe operation vagina is divided into three

sections.(First,the probe reaches the cervical orifice .From inside to

outside. inside .middle .outside);Use 4.5 probe at first,then use 3.0


probe to operate in the same way; During the whole process, the probe
is close to the vaginal wall.(30-140 minutes)
⑽ Insert the probe into the end of the vagina, and the "0" scale is at the top.

If the automatic mode is selected, it can be completed by pressing the


operation button on the handle once,and reset automatically.

⑾ For example, the selection is manual mode, press the button on the

handle to send out a line, after the dotting operation is completed, the
handle is suspended after rotating the preset angle,and then press the
button on the handle to send out a line,the handle rotates the angle
again,so repeat the operation until the operation of the current setup is

complete.

⑿ Manual mode is to hit the line by clicking until a circle of 360 degrees

is completed and the handle is reset by itself.

⒀ After the operation,remove the condom and clean the probe and handle

with detergent.
⒁ Following is a demonstration of intravaginal therapy:

Two paragraph

Third paragraph 360° Automatic Control of Rotation Angle


Intravaginal: treatment demonstration

Before operation In operation After operation

⒂ Privacy Postoperative Notes:

-No special care is needed, Normal cleaning is enough.


-There will be slight swelling in the vagina after the operation. Tell the
guest not to worry. It usually subsides in about five hours.There may also

be minimal white energy points at some therapeutic sites, but these are

usually normal, mild and temporary responses.

-secretion will increase,it is a normal phenomenon, be ever prepared


Cushion.

-In very few cases, small blood spots appear in the vaginal mucosa and
disappear automatically within days and weeks.The reason is the improper
operation of the operator during the treatment and the excessive energy
acting on the mucosa.

-If you want to be treated with other equipment after treatment, you
must be one month later.

-One week after treatment, normal sexual life can be achieved.


-One course of treatment is 3-5 times and one month for 1 time.
Taboos for Instrument Users
When using 7D instruments, the following symptoms should be

carefully observed. Details are as follows:

1 .Before using the instrument,the skin of the physiotherapy site should

be cleaned and cleaned,To prevent dirt from entering the skin with

ultrasound or to prevent the penetration of ultrasound . Before

treatment, please Take off all the metal objects on your body first.In

order to avoid the unexpected situation and affect the curative effect.

2 . It is better to use a certain viscosity with the medium, which is

conducive to the better integration of ultrasound and skin, Prevent the

gap from reflecting, which is disadvantageous to sound transmission.

3 .Each treatment area can not be repeated too much, up to three times, to avoid
skin redness and swelling.

4 .The degree of probe heat does not represent the output of ultrasonic
power. Low concentration of water or drugs should not be directly
penetrated, otherwise it is easy to cause dry skin.

5 .When using the instrument, the probe should not be close to the eye
or pass through the eyeball.

6 .Patients who are suffering from illness should also use the instrument
carefully unless the doctor's permission is obtained.

7 . Patients with malignant tumors,hemophilia or severe bleeding.

8 . Use cautiously in patients with major diseases, skin diseases and

infectious diseases.

9 . Heart, brain, cervical nerve center, spine, eyeball, hemorrhage,

injection.

10 .Pregnant women, diabetes mellitus,menstruation,hyperthyroidism,


hypertension and other patients to avoid operation.

11.Injection of hyaluronic acid should wait six months before ultrasound


scalpel treatment can be carried out.

12 .Do not drink or eat spicy food after 4D treatment. Do not wash your

face with overheated water or supercooled water within a week. Do not


apply high temperature yoga, sauna, steamed face and facial massage
(avoid facial squeezing). Apply the mask to replenish the water every day
for a week. Pay attention to sunscreen. Do not use radiofrequency and
light apparatus for treatment within one month.

The following symptoms should be used with caution,Details

are as follows:
1. This instrument is forbidden for those who have no experience in

sexual life, pregnancy or Just abortion .

2. It is forbidden during menstruation or within one day before and


after menstruation.

3 . It is not suitable for patients with common diseases in the onset stage,It

is suggested that the body be restored and treated again.

4 .Cancer patients are forbidden in the vicinity of vagina, and severe

venereal diseases are forbidden.

5 .Use cautiously in patients with minor surface trauma on the inner

wall of the vagina,above moderate trauma ,It is forbidden to use.

6 .Cervical erosion secondary and moderate vaginitis, severe

gynecological disease patients are forbidden to use;

7 .No strenuous exercise for one day after the end of the course,You

can't ride a bicycle for a week,can't bath in a tub,Prohibition of Sexual

Life.

8 .After the course of treatment, please pay attention to diet, fasting raw

and cold, spicy, hot and dry food.Do not take aspirin and other

anticoagulant drugs, do not smoke, eat more vegetables and fruits to

prevent constipation.

9 .Treatment is available six months or one year after delivery.If artificial

breastfeeding is still carried out six months after delivery, it is necessary


to wait until complete weaning is stopped before treatment.

Common Faults of Instruments


1 .The interface of the instrument is not displayed. Please check whether

the power plug is properly connected or whether the power switch is turned
on.
2 .The instrument is normal but has no energy output or has been

alarming after booting. Please check whether the handle wire is firmly

connected to the main engine or whether the probe is installed in place.

Maintenance and Maintenance of


Instruments
1 .After using the instrument, please clean it with alcohol disinfection
and keep it properly.

2 .The plug with grounding pin must be used before use, and ensure that the
power socket of the instrument is truly grounded.

3 .The instrument voltage is suitable. If the local power supply voltage is

unstable, we suggest that users increase the power matching regulated

power supply.

4 .The therapeutic effect of the instrument and its normal service life

should be guaranteed. Please use the specified accessories provided or

recommended by the original manufacturer.

5.Do not place it in wet places or near water sources,and do not expose
the instrument directly to sunlight.

6 .The instrument should not approach the strong heat source, because this
may affect the life and normal use of the instrument.

7 .Please take off all metal objects from your body first, so as to avoid

unexpected conditions affecting the curative effect.

8 .Avoid bad contact, please pay attention to contact the skin to have
a certain degree of wetness, water products or water wipe can

achieve the desired effect.

9 .Turn off the power switch when the instrument is not in use,And

ensure that the total power supply of the instrument is switched off

before and after use to ensure the safety of the electrical products.

10 .Use the instrument strictly in accordance with the instructions in

the manual or use the instrument strictly according to the instructions

of the operator of the training instrument.

Instrument Technical Parameters and


Packaging Dimensions
Product name: three in one Input voltage: AC110V - 220V

Output power: 10-200W Fuse: 5A

You might also like