Network Appliance - Pre .NS0 173.by .VCEplus DEMO
Network Appliance - Pre .NS0 173.by .VCEplus DEMO
Network Appliance - Pre .NS0 173.by .VCEplus DEMO
60q
Number: NS0-173
Passing Score: 800
Time Limit: 120 min
File Version: 1.0
Website: https://vceplus.com
VCE to PDF Converter: https://vceplus.com/vce-to-pdf/
Facebook: https://www.facebook.com/VCE.For.All.VN/
Twitter : https://twitter.com/VCE_Plus
NS0-173
Version 1.0
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Exam A
QUESTION 1 Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only
NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)
Correct Answer: BD
Section: (none)
Explanation
Explanation/Reference:
QUESTION 2
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?
A. trunk mode
B. end host mode
C. switching mode
D. access mode
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/16411-nva-0025-deploy.pdf
QUESTION 3
The storage administrator must change the vHBA settings bound to a template associated with a production server.
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
QUESTION 4
A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see any FC LUNs from the NetApp AFF systems.
In this scenario, which three configuration elements should the customer verify? (Choose three.)
A. FC zoning
B. igroup configuration
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
C. ALUA settings
D. FC portsets
E. MTU configuration
Explanation/Reference:
QUESTION 5
You are a data center architect at a service provider. You need to configure a new multi-tenant FlexPod service offering.
Which three UCS Manager features will you need to accomplish this task? (Choose three.)
A. auto discovery
B. role-based access control
C. service profiles
D. virtualization support
E. policies
Explanation/Reference:
QUESTION 6 Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP
storage cluster.
A. Use the existing Nexus 93108 switches for the cluster interconnect.
B. Add two Nexus 3232C switches for the cluster interconnect.
C. Add two Nexus 93108 switches for the cluster interconnect.
D. Add one Nexus 3232C switch for the cluster interconnect.
Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
QUESTION 7
A customer is designing a FlexPod solution with VMware 6.x in a SAN boot environment using FCoE. The customer has predetermined the WWPN values for the NetApp LIFs and the UCS vHBAs. The customer is now working on the design
workflow for the SAN boot process.
In this scenario, which three FlexPod environment objects are required for SAN connectivity? (Choose three.)
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Section: (none)
Explanation
Explanation/Reference:
QUESTION 8
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
A. UCS Central
B. NetApp OnCommand Unified Manager
C. NetApp OnCommand Insight
D. UCS Director
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
QUESTION 9
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?
A. monitor port
B. appliance port
C. uplink port
D. server port
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
QUESTION 10
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)
A. Cisco
B. VMware
C. Microsoft
D. NetApp
E. Red Hat
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_openstack_osp6_design.html
QUESTION 11
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Your customer has a FlexPod implementation and wants to use life-cycle management to validate, monitor, and optimize the FlexPod infrastructure.
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Explanation:
Cisco UCS Director can be an integral companion for FlexPod because it allows holistic management through centralized automation and orchestration from a single, unified view. When FlexPod and Cisco UCS Director are combined, IT
can shift time and focus from managing infrastructure to delivering new service innovation. Used together, FlexPod and Cisco UCS Director deliver: Reference: https://www.netapp.com/media/16859-tr-3884.pdf
QUESTION 12
Click the Exhibit button.
A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which
two configurations shown in the exhibit satisfy the customer’s requirements? (Choose two.)
A. I.
B. II.
C. III.
D. IV
Correct Answer: CD
Section: (none)
Explanation
Explanation/Reference:
QUESTION 13
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be
replicated to the new location.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
C. SnapMirror
D. FlexCache
Correct Answer: CD
Section: (none)
Explanation
Explanation/Reference:
Explanation:
FlexClone®: Instant virtual copies with file and volume granularity
SnapMirror®: Integrated data replication technology for simple, efficient, flexible disaster recovery and backup use cases
Reference: https://www.inneo.ch/files/content/Informationstechnologien/Storage-Server-Netzwerk/datenblatt-netapp-fas-2700-storage.pdf
QUESTION 14
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)
Correct Answer: CD
Section: (none)
Explanation
Explanation/Reference:
Explanation:
C: When using this matrix to determine recommended driver versions for you server configuration, please reference the server’s Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed
Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry's leading converged infrastructure solutions
Reference: https://ucshcltool.cloudapps.cisco.com/public/#
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/release-notes/6-7/cisco-ucs-director-release-notes-67.html
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?
A. 6332-16UP
B. 6332
C. 6248UP
D. 6296UP
Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Explanation:
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput and up to 32 ports. The switch has 32 40Gbps fixed Ethernet. Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60u2_fc_design.html
QUESTION 16
You are configuring high availability within the network layer of your FlexPod configuration.
In this scenario, what are two Cisco best practices for designing vPC on your Cisco 9000 Series switches? (Choose two.)
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
A. Peer keep-alive connectivity between the switches should be established.
B. A minimum of four 10GB Ethernet connections are required for vPC.
C. The vPC auto-recovery feature should be enabled.
D. Port channels should be configured for LACP passive mode.
Correct Answer: AB
Section: (none)
Explanation
Explanation/Reference:
Explanation:
vPC also relies on the periodic keepalive messages to determine when one of the connected devices on the peer link fails. vPC peer link – The link used to synchronize
states between the vPC peer devices. Both ends must be on 10-Gigabit Ethernet or 40-Gigabit Ethernet interfaces.
Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/interfaces/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide/b_Cisco_Nexus_9000_Series_NX-
OS_Interfaces_Configuration_Guide_chapter_0111.html
QUESTION 17
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
A. Cluster mode
B. Direct Connect mode
C. SingleConnect mode
D. DualWire Management mode
E. Multipath mode
Explanation/Reference:
Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data
traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack-Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C-Series Rack-Mount Servers
using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series-Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html
QUESTION 18
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
A. 2204XP.
B. 2208XP
C. 2232
D. 2304
Correct Answer: A
Section: (none)
Explanation
Explanation/Reference:
Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Reference: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17-644224.pdf
QUESTION 19 Your customer wants assurances that all aspects of FlexPod are
highly available.
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Explanation:
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such
as data replication and application-level clustering technologies.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Infrastructure-Mgmt/3-1/b_UCSM_GUI_Infrastructure_Management_Guide_3_1/
b_UCSM_GUI_Infrastructure_Management_Guide_3_1_chapter_0110.html
QUESTION 20
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Explanation:
On rare occasions, such as an issue with the current running firmware, troubleshooting a server may require you to reset the CIMC to the factory default. When this happens, all user-configurable settings are reset. This procedure is not part of
the normal server maintenance. After you reset the CIMC, you are logged off and must log in again. You may also lose connectivity and may need to reconfigure the network settings.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-0_1x/b_Cisco_CIMC_C250_CLI_Configuration_Guide/Cisco_CIMC_C250_CLI_Configuration_Guide_chapter13.pdf
QUESTION 21
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)
A. leaf switch
B. core switch
C. cluster interconnect switch
D. spine switch
Correct Answer: AD
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/application-centric-infrastructure/white-paper-c11-737909.html
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
QUESTION 22
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)
A. templates
B. blade servers
C. service profiles
D. boot from SAN
Correct Answer: BC
Section: (none)
Explanation
Explanation/Reference:
Explanation:
Cisco introduced the idea of stateless computing with its blade server design.
A Cisco UCS instance allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature.
Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled
downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.
QUESTION 23
A FlexPod solution has been configured for iSCSI SAN boot with multiple paths between the server and the storage. In
this scenario, how many initiators (IQNs) per server will need to be added in the corresponding igroup in ONTAP?
A. three
B. one
C. four
D. two
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Explanation:
The initator group REST API allows you to create, update, delete, and discover initiator groups, and add and remove initiators that can access the target and associated LUNs. Reference:
https://library.netapp.com/ecmdocs/ECMLP2858435/html/resources/igroup.html
QUESTION 24
A customer is investigating options for implementing a FlexPod Datacenter solution that is using vSphere 6.x.
In this scenario, which two resources would be important to review? (Choose two.)
Correct Answer: BD
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60_n9k.html
QUESTION 25 A customer wants to extend a Layer 2 network over a Layer 3 Nexus 9000
infrastructure.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Which Layer 2 overlay scheme accomplishes this task?
A. STP
B. vPC
C. VXLAN
D. EIGRP
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Explanation:
XLAN tunnels the Layer 2 network over the Layer.
Reference: https://www.ciscopress.com/articles/article.asp?p=2999385&seqNum=3
QUESTION 26
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?
A. MDS9148>show fcfwd
B. MDS9148>show fcdomain
C. MDS9148>show fcc
D. MDS9148>show flogi database
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-1121.pdf
QUESTION 27
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
A. NetApp StorageGRID
B. NetApp SolidFire
C. NetApp EF-Series
D. NetApp AFF
Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/10608-tr-4636.pdf
QUESTION 28
A customer with a FlexPod Datacenter design that uses a 4-node FAS8200 for storage wants to add a new workload that requires high performance. The customer needs to nondisruptively move some workloads from the existing FAS system
to the new storage.
A. FAS2700
B. AFF A300
C. EF570
D. E2700
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/pdf.html?item=/media/16341-tr-4637pdf.pdf
QUESTION 29
You are asked to design a FlexPod solution with a Cisco UCS B-Series chassis. There is no requirement for any Cisco UCS C-Series rack servers. You must ensure that there is a minimum of a 2500 VLAN or VSAN capacity per UCS domain.
A. 6332
B. 6248
C. 6296
D. 6324
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/CLI-User-Guides/Storage-Mgmt/3-2/b_CLI_UCSM_Storage_Management_Guide_3_2.pdf
QUESTION 30
A client has a requirement to set up a FlexPod Datacenter with the NetApp fabric MetroCluster architecture. You want to enable connectivity between the deployments.
In this design, which two components are required to accomplish this task? (Choose two.)
Correct Answer: AD
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/12434-nva-0030-design.pdf
QUESTION 31
Click the Exhibit button.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
QUESTION 32
An architect is designing a FlexPod environment with Cisco Nexus 5000 switches to SAN boot all of the ESXi hosts over FC.
A. LUN 2
B. LUN 3
C. LUN 0
D. LUN 1
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_50_M3.html
QUESTION 33
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)
Explanation/Reference:
QUESTION 34 A customer wants to deploy FlexPod for a VDI solution with 10,000 users, each with 10 GB of
storage allocated.
To support this configuration, which three components must be sized? (Choose three.)
Explanation/Reference:
QUESTION 35
Click the Exhibit button.
Referring to the exhibit, what is the name given to the link between the two Cisco Nexus switches?
A. vPC Domain ID
B. vPC peer domain
C. vPC peer link
D. vPC peer connection
Correct Answer: C
Section: (none)
Explanation
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/layer2/503_n2_1/503_n2_1nw/Cisco_n5k_layer2_config_gd_rel_503_N2_1_chapter8.html
QUESTION 36
A customer is designing a FlexPod solution to use both NFS and iSCSI for connectivity, including traditional FC for legacy applications. The Cisco UCS Fabric Interconnects will be connected to both Nexus 9000 Series switches and FC switches.
A. FC uplink ports
B. VSANs
C. unified ports
D. SAN pin groups
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
QUESTION 37
A customer wants to configure SAN boot for its FlexPod system. The customer must consider the minimum number of FC ports to be configured on each node in the ONTAP storage solution.
In this scenario, what is the minimum number of FC ports that should be configured per storage node?
A. two
B. one
C. three
D. four
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/12424-tr4036.pdf (11)
QUESTION 38
A customer recently configured its Cisco UCS, and within the Chassis Discovery policy, they set the link group preference to Port Channel.
Which two benefits would they derive from this link group preference? (Choose two.)
A. All the links between the Cisco Fabric Interconnects and chassis IOM are shared.
B. Each blade has an assigned Cisco Fabric Interconnects link.
C. All the links between the Cisco Fabric Interconnects and chassis IOM are pinned.
D. Traffic is load balanced across the links.
Correct Answer: AD
Section: (none)
Explanation
Explanation/Reference:
QUESTION 39
Click the Exhibit button.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
The total number of servers that a Cisco UCS Mini chassis supports is set to a maximum of how many hosts as shown in the exhibit?
A. 22
B. 12
C. 20
D. 8
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
QUESTION 40
A service provider is designing a FlexPod configuration to host multiple customers in a hybrid cloud environment, where IP address-range conflicts might arise on the shared storage.
A. SVMs
B. broadcast domains
C. IPspaces
D. failover groups
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
QUESTION 41
What are characteristics of the Cisco UCS 5108 blade chassis?
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
A. 4 RU, 6 half-width UCS B-Series blades, 160 Gbps I/O bandwidth
B. 6 RU, 8 half-width UCS B-series blades, 160 Gbps I/O bandwidth
C. 6 RU, 6 half-width UCS B-series blades, 80 Gbps I/O bandwidth
D. 4 RU, 8 half-width UCS B-series blades, 40 Gbps I/O bandwidth
Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17-644224.pdf
QUESTION 42 A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the
zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_datacenter_vmware_netappaffa_design.html#_Toc23952741
QUESTION 43
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS
B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
Correct Answer: A
Section: (none)
Explanation
Explanation/Reference:
QUESTION 44 A customer has verified physical connectivity on the FlexPod. However, the LUNs are not available on the Cisco UCS server. To make the LUNs visible to the UCS, the customer must enable a switching feature
for zoning.
Correct Answer: D
Section: (none)
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Explanation
Explanation/Reference:
In this scenario, which three storage protocols are available for use? (Choose three.)
A. InfiniBand
B. CIFS
C. iSCSI
D. NFS
E. FC
Explanation/Reference:
QUESTION 46 A customer is planning to use a pair of MDS switches in a FlexPod design to host a few
SAN workloads.
In this scenario, which two features should be enabled on the MDS switches for a successful configuration? (Choose two.)
A. NPIV
B. NPV
C. port-channel-trunk
D. fport-channel-trunk
Correct Answer: AC
Section: (none)
Explanation
Explanation/Reference:
QUESTION 47 You are asked to design a FlexPod solution that meets the minimum requirements and includes Application Centric
Infrastructure (ACI).
Which three Cisco components are required in this scenario? (Choose three.)
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi55u2_n9k_aci_aff8040_design.html
QUESTION 48
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
You are configuring Cisco UCS servers for FC SAN boot and want to perform zoning on your Cisco Nexus 5000 series switches.
A. The corresponding FC ports on your NetApp storage array must be configured in LACP mode.
B. An iSCSI license on the NetApp storage controller is required.
C. SAN links are required between the Cisco Fabric Interconnects and the Nexus 5000 switches.
D. FC zoning on the Nexus series switches is not supported; zoning can be done only on the Cisco Fabric Interconnects.
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/b_UCSM_GUI_Configuration_Guide_2_2_chapter_011011.html
QUESTION 49
Which Cisco Nexus series switch supports NX-OS standalone mode or Application Centric Infrastructure (ACI) fabric mode?
A. Nexus 7000
B. Nexus 3000
C. Nexus 9000
D. Nexus 5000
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/products/collateral/switches/nexus-9000-series-switches/guide-c07-733228.html
QUESTION 50
After you install a FlexPod infrastructure at a customer site, you need to migrate the existing Vmware virtual machines off the infrastructure that was used before FlexPod was installed.
A. vMotion
B. vSphere DRS
C. VM Component Protection
D. vSphere HA
Correct Answer: A
Section: (none)
Explanation
Explanation/Reference:
QUESTION 51
You are configuring a FlexPod system for NAS protocols. You want to ensure that there are multiple paths between the initiators and targets in the solution. Which
Correct Answer: BC
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
Section: (none)
Explanation
Explanation/Reference:
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi65u1_n9fc.html#_Toc24048288
QUESTION 53 A customer with a FlexPod Express solution wants to enable remote access to the NetApp
storage component. In this scenario, which two access methods are recommended? (Choose two.)
A. SAML
B. SSH
C. RDP
D. Telnet
Correct Answer: BD
Section: (none)
Explanation
Explanation/Reference:
QUESTION 54
Two data centers are 75km apart. The customer wants to deploy a FlexPod solution in each data center to maintain high availability between the two sites with minimal possible data loss.
In this scenario, which technology would you use at the NetApp storage layer?
A. MetroCluster
B. SnapMirror
C. SnapVault
D. FlexArray
Correct Answer: A
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/12434-nva-0030-design.pdf
QUESTION 55
Click the Exhibit button.
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
You have designed a FlexPod Express solution that uses a NetApp ONTAP controller, Cisco UCS C-Series servers, and Cisco Nexus 3000 Series switches, as shown in the exhibit. Which
A. SMB
B. NFS
C. iSCSID. FC
E. FCoE
Explanation/Reference:
Reference: https://www.netapp.com/media/12441-nva-0016-flexpod-express.pdf (21)
QUESTION 56 Which port type would you configure when you connect a chassis to the Cisco Fabric
Interconnects?
Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/12424-tr4036.pdf (16)
In this scenario, what is the smallest size possible for the pool?
A. 33
B. 34
C. 68
D. 66
Correct Answer: D
Section: (none)
Explanation
Explanation/Reference:
QUESTION 58
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com
A customer with a FlexPod Express configuration is currently operating Linux servers. The company wants to move to a Windows-centralized access method for the NetApp storage component.
In this scenario, which two ONTAP features must be configured? (Choose two.)
Correct Answer: AB
Section: (none)
Explanation
Explanation/Reference:
QUESTION 59
Which two NetApp storage controllers would be used in a valid FlexPod Datacenter configuration? (Choose two.)
A. NetApp FAS2700
B. NetApp AFF A700
C. NetApp E2800
D. NetApp EF570
Correct Answer: AB
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.netapp.com/media/12424-tr4036.pdf
QUESTION 60
A customer is configuring the UCS to handle a multitenant environment. The customer has created an organization within UCS for each tenant and would like to allow access to these organizations for only users that belong to that tenant.
In this scenario, which feature in UCS Manager should the customer use to accomplish this task?
A. Locales
B. Trusted Platform Module
C. Service Profile
D. User Roles
Correct Answer: C
Section: (none)
Explanation
Explanation/Reference:
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Admin-Management/3-2/b_Cisco_UCS_Admin_Mgmt_Guide_3_2/b_Cisco_UCS_Admin_Mgmt_Guide_3_2_chapter_01010.html
www.vceplus.com - Free Questions & Answers - Online Courses - Convert VCE to PDF - VCEplus.com