A&D PI14, Mr. Voisin, 19.01.

2006

Free programmable
Stand-alone-scale
For a very competitive and free programmable Stand-alone-
scale the following components are required:

1. S7-200 CPU (CPU 222 oder higher)


2. weighing module MicroScale
3. load cell
4. HMI-Panel (e.g. TP177micro or TD100C)

4. 4.

or

1. 2.

3.
3. 3.

755608577.doc Seite 1 von 3


A&D PI14, Mr. Voisin, 19.01.2006

1 scale with one HMI-Panel TD 100C:

Components: Number: Order-Nr.:


CPU222 with power supply 1 6ES7212-1BB23-0XB0
120…240VAC
Weighing module MicroScale 1 7MH4930-0AA01
HMI-Panel TD100C 1 6ES7272-1BA10-0YA0

1 scale with one HMI-Panel TP 177micro:

Components: Number: Order-Nr.:


CPU222 with power supply 1 6ES7212-1BB23-0XB0
120…240VAC
Weighing module MicroScale 1 7MH4930-0AA01
HMI-Panel TP177micro 1 6AV6640-0CA11-0AX0

2 scales with one HMI-Panel TP177micro:

Components: Number: Order-Nr.:


CPU222 with power supply 1 6ES7212-1BB23-0XB0
120…240VAC
Weighing module MicroScale 2 7MH4930-0AA01
HMI-Panel TP177micro 1 6AV6640-0CA11-0AX0

3 scales with one HMI-Panel TP177micro:

Components: Number: Order-Nr.:


CPU224 with power supply 1 6ES7214-1BD23-0XB0
120…240VAC
Weighing module MicroScale 3 7MH4930-0AA01
HMI-Panel TP177micro 1 6AV6640-0CA11-0AX0

755608577.doc Seite 2 von 3


A&D PI14, Mr. Voisin, 19.01.2006

Potential added required components:

Components: Number: Order-Nr.:


Sectional Rail 35x7,5mm 1 6ES5 710-8MA11
(EN50-022), Length=483mm
Ground terminal 1 6ES5728-8MA11
Power cable with grounding connexion 1 -
PC/PPI-cable 1 6ES7 901-3CB30-0XA0
SIWATOOL cable 1 7MH4 702-8CA
SIWAREX MS – PC
cable TD100C to S7-200 1 6ES7901-3EB10-0XA0
STEP 7-Micro/WIN 1 6ES7810-2CC03-0YX0
(building of control programmes)
SIWAREX MS configuration package 1 7MH4 930-0AK01
SIMATIC WinCC flexible 2005 micro 1 6AV6610-0AA01-1CA8
(project planning of TP177micro)

note:

The choice of the type and number of the load cells, as soon as the required mounting parts
are dependent of the application.

755608577.doc Seite 3 von 3