en Chapter Protrac
en Chapter Protrac
en Chapter Protrac
The advantages
54
PRO PRO PRO
Application Level and interface measurement Level and interface measurement Level and interface measurement
of liquids and bulk solids of liquids and bulk solids of liquids and bulk solids
Measuring range up to 7 m up to 7 m up to 3 m
Version Sensor with flexible plastic Sensor with flexible plastic Sensor with PVT rod detector
detector ø 42 mm detector ø 60 mm
Mounting From outside on the vessel From outside on the vessel From outside on the vessel
Signal output 4 … 20 mA/HART, Profibus PA, 4 … 20 mA/HART, Profibus PA, 4 … 20 mA/HART, Profibus PA,
Foundation Fieldbus Foundation Fieldbus Foundation Fieldbus
Approvals ATEX, UKEX, IECEx, NEPSI, FM, ATEX, UKEX, IECEx, NEPSI, FM, ATEX, UKEX, IECEx, NEPSI, FM,
CSA, EAC (GOST), INMETRO, CSA, EAC (GOST), INMETRO, CSA, EAC (GOST), INMETRO,
CCOE, TIIS, KOSHA/KTL, SIL2 CCOE, TIIS, KOSHA/KTL, SIL2 CCOE, TIIS, KOSHA/KTL, SIL2
Benefit
Simple installation on round Cost savings through the use Maximum accuracy through
and conical vessels via flexible of only one sensor for a PVT detector
detector measuring range of up to 7 m
and reduces source size
needed
55
Radiation-based
Application Level detection of liquids Density measurement of liquids Mass flow determination of bulk
and bulk solids and bulk solids solids on belts and in screw
conveyors
Version Sensor with PVT rod detector Sensor with integrated Nal With PVT rod detector
detector in protective tube of 316L
Mounting From outside on pipeline From outside on pipeline or on Through supplied measuring frame
or on vessel vessel
Signal output 8/16 mA/HART, Profibus PA, 4 … 20 mA/HART, Profibus PA, 4 ... 20 mA/HART, Profibus PA,
Foundation Fieldbus Foundation Fieldbus Foundation Fieldbus
Approvals ATEX, UKEX, IECEx, NEPSI, FM, ATEX, UKEX, IECEx, NEPSI, FM, ATEX, UKEX, IECEx, NEPSI, FM,
CSA, EAC (GOST), INMETRO, CSA, EAC (GOST), INMETRO, CSA, EAC (GOST), INMETRO,
CCOE, TIIS, KOSHA/KTL, SIL2 CCOE, TIIS, KOSHA/KTL, SIL2 CCOE, TIIS, KOSHA/KTL
Benefit
Reliable limit level detection by Simple, retro installation, even Wear-free due to non-contact
a PVT scintillator eliminates the in confined spaces, during measurement
need for early replacement of ongoing production processes
the source thanks to compact design
56
VEGASOURCE 31 VEGASOURCE 35 SHLD1
Application Source container for radioactive Source container for radioactive Source container for radioactive
isotope isotope isotope
Measuring range 5°, 20° (±10°), 40° (±20°) 5°, 20° (±10°), 40° (±20°) 0°, 15°, 30°, 45°, 60° (±30°)
Version Cs-137: For activities Cs-137: For activities Cs-137: For activities
up to 18.5 GBq (500 mCi) up to 111 GBq (3000 mCi) up to 3.7 GBq (100 mCi)
Co-60: For activities Co-60: For activities
up to 0.74 GBq (20 mCi) up to 3.7 GBq (100 mCi)
Non-repeatability – – –
Mounting Flange DN 100 PN 16, 4" 150 lbs Flange DN 100 PN 16, 4" 150 lbs Mounting plate or L profile
152 mm (6")
Signal output Optionally with ON/OFF position Optionally with ON/OFF position Optionally with ON/OFF position
switch switch switch
Approvals – – –
Benefit
Reliable shielding allows use without control areas Ideal for mass flow determiniation
with an aperture angle of
45° and 60°
57
Radiation-based
Application Source container for radioactive Source container for radioactive Source container for radioactive
isotope isotope isotope
Measuring range 5°, 30°, 40° (± 20°), 45°, 60° (± 30°) 5°, 30°, 40° (± 20°), 45°, 60° (± 30°) 5°, 30°, 40° (± 20°), 45°, 60° (± 30°)
Version Cs-137: For activities Cs-137: For activities Cs-137: For activities
up to 740 MBq (20 mCi) up to 11 GBq (300 mCi) up to 185 GBq (5000 mCi)
Non-repeatability – – –
Mounting Mounting plate 152 x 152 mm Mounting plate 216 x 216 mm Mounting plate 315 x 315 mm
(6 x 6") (8.5 x 8.5") (12.4" x 12.4")
Signal output Optionally with ON/OFF position Optionally with ON/OFF position Optionally with ON/OFF position
switch switch switch
Approvals – – –
Benefit
Minimal space requirement Trustworthy shielding allows Trustworthy shielding allows
due to compact design with use without control areas use without control areas
low weight (11 kg) (34 kg) (82 kg)
58
59