E5® Internal Cure SDS
E5® Internal Cure SDS
E5® Internal Cure SDS
1. IDENTIFICATION
Carcinogenicity:
IARC : No ingredient of this product present at levels greater than or equal to 0.1% is
identified as probable, possible or confirmed human carcinogen by IARC.
OSHA : No component of this product present at levels greater than or equal to 0.1% is on
OSHA’s list of regulated carcinogens.
NTP : No component of this product present at levels greater than or equal to 0.1% is
identified as a known or anticipated carcinogen by NTP.
3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance / Mixture : Mixture
Common Name : Amorphous Silica, aqueous colloidal solution.
Components
CHEMICAL NAME CAS-No. CONCENTRATION (% w/w)
Inhalation : If breathed in, move person into fresh air. Consult a physician
after significant exposure.
Oral : Clean mouth with water and drink afterwards plenty of water.
Never give anything by mouth to an unconscious person.
Obtain medical attention.
Notes to Physician
Symptoms : No information available.
Risks : No information available.
Treatment : Treat symptomatically.
Emergency measures on
accidental release : Follow safe handling advice and personal
Page: 3 of 12
E5® Internal Cure
Revision Date: 12/08/2017
Version 1.0 US/Z8 Date of Last Issue: - Date of First Issue: -
Odor : slight
E5® Internal Cure Revision Date: 12/08/2017 Page: 5 of 12
Version 1.0 US/Z8 Date of Last Issue: - Date of First Issue: -
pH : 9 - 11
Melting point/range : 0 °C
Solubility(ies)
Water solubility : dispersible
Viscosity
Viscosity, dynamic : < 50 mPa.s
This material safety datasheet only contains information relating to safety and does not
replace any product information or product specification
E5® Internal Cure Revision Date: 12/08/2017 Page: 6 of 12
Version 1.0 US/Z8 Date of Last Issue: - Date of First Issue: -
10. STABILITY AND REACTIVITY
Reactivity : Stable under normal conditions.
STOT-single exposure
Not classified based on available information.
STOT-repeated exposure
Not classified based on available information.
Aspiration toxicity
Not classified based on available information.
Aggravated Medical
Condition : None known.
Symptoms of
Overexposure : No information available.
Toxicology Assessment
Further information : Information given is based on data on the ingredients and the
toxicology of similar products.
Test result
Acute oral toxicity : LD50: > 5,000 mg/kg
Species: Rat
The value is estimated from tests on similar products.
Sensitization : Result: Did not cause sensitization on laboratory animals.
Method: (Magnusson-Kligman):
The value is estimated from tests on similar products.
Germ cell
mutagenicity
Genotoxicity in vitro : Ames test
Result: negative
Method: OECD Test Guideline 471
The value is estimated from tests on similar products.
Carcinogenicity:
IARC No ingredient of this product present at levels greater than or equal to
0.1% is identified as probable, possible or confirmed human
carcinogen by IARC.
OSHA No component of this product present at levels greater than or equal
to 0.1% is on OSHA’s list of regulated carcinogens.
NTP No ingredient of this product present at levels greater than or equal to
0.1% is identified as a known or anticipated carcinogen by NTP.
Test Result
Ecotoxicity Effects
Toxicity to fish : LC50: > 5,000 mg/l
Exposure time: 96 h
Species: Danio rerio (zebra fish)
The value is estimated from tests on similar products.
Toxicity to daphnia : EC50: 7,600 mg/l
and other aquatic Exposure time: 48 h
invertebrates Species: Ceriodaphnia dubia (water flea)
The value is estimated from tests on similar products.
E5® Internal Cure Revision Date: 12/08/2017 Page: 8 of 12
Version 1.0 US/Z8 Date of Last Issue: - Date of First Issue: -
Toxicity to algae : NOEC: 60 mg/l
Exposure time: 48 h
Species: Selenastrum capricornutum (green algae)
The value is estimated from tests on similar products.
Bioaccumulative
potential : Bioaccumulation is not expected.
Distribution among
environmental
compartments : Transport to air is not expected.
INGREDIENTS:
Ecotoxicology Assessment
Component: silicon dioxide
Additional ecological
information : No data available
13.
13) DISPOSABLE CONSIDERATIONS
DISPOSAL CONSIDERATIONS
Contaminated
Packaging : Empty remaining contents.
Empty containers should be taken to an
approved waste handling site for recycling or disposal.
Page: 9 of 12
E5® Internal Cure Revision Date: 12/08/2017
Version 1.0 US/Z8 Date of Last Issue: - Date of First Issue: -
14. TRANSPORT INFORMATION
International Regulations
ADR
Not regulated as a dangerous good
UNRTDG
Not regulated as a dangerous good
IATA-DGR
Not regulated as a dangerous good
IMDG-Code
Not regulated as a dangerous good
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable for product as supplied.
Domestic regulation
49 CFR
Not regulated as a dangerous good
TDG
Not regulated as a dangerous good
NOM-002-SCT
Not regulated as a dangerous good
This product does not contain any hazardous air pollutants (HAP), as defined by
the U.S. Clean Air Act Section 112 (40 CFR 61).
This product does not contain any chemicals subject to disclosure and listed
under the U.S. Clean Air Act Section 112(r) for Accidental Release Prevention (40
CFR 68.130, Subpart F).
This product does not contain any chemicals listed under the U.S. Clean Air Act
Section 111 SOCMI Intermediate or Final VOC's (40 CFR 60.489).
This product does not contain any chemicals listed under the U.S. Clean Air Act
Section 111 SOCMI Intermediate or Final VOC's (40 CFR 60.489).
This product does not contain any Hazardous Substances listed under the U.S.
CleanWater Act, Section 311, Table 116.4A.
This product does not contain any Hazardous Chemicals listed under the U.S.
CleanWater Act, Section 311, Table 117.3.
This product does not contain any toxic pollutants listed under the U.S. Clean
Water Act Section 307
California Prop. 65
This product does not contain any chemicals known to the State of California to
cause cancer, birth, or any other reproductive defects.
Further information
Revision Date 12/08/2017
n
The information in this material safety data sheet should be provided to all who will use, handle, store,
transport or otherwise be exposed to this product. The user must determine the appropriate measures that
need to be implemented for the use and handling of this product in the context of the user's operations and
use of this product. The information contained herein supersedes all previously issued bulletins on the
subject matter covered. If the date on this document is more than three years old,call to make certain that
this sheet is current. No warranty is made as to the product’s merchantability or fitness for any particular
purpose, or that any suggested use will not infringe any patent. User must determine for himself, by
preliminary tests or otherwise, the suitability of this product for his purposes, including mixing with other
products. Nothing contained herein shall be construed as granting or extending any license under any patent.
The information provided in this material Safety Data Sheet is correct to the best of our knowledge,
information and belief at the date of its publication. The information given is designed only as a guidance for
safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a
warranty or quality specification. The information relates only to the specific material designated and may
not be valid for such material used in combination with any other materials or in any process, unless
specified in the text.