Unicare MCF-21B Fetal Monitor Brochure
Unicare MCF-21B Fetal Monitor Brochure
Unicare MCF-21B Fetal Monitor Brochure
UNICARE
CE/ISO/RoHS/CFDA
Features
Core • Optional Support HL7 (Health Level Seven)
• Newly advanced A9 main board with Linux OS,
calculating speed is 4 times faster than traditional Alarm
products • Three-level acousto-optic alarm
• Support storage of 25000 groups of medical record and • FHR signal strength prompt
8640 hours trend review • Cross-Channel Verification (CCV) provides visual
and audible indication when it detects synchronous fetal
Body or maternal heart rate signals, indicating that you may be
• 12.1 inch Folded high-brightness TFT LED monitoring a duplicate signal)
• Optional touch screen • Sensor-off alarm
• Humanized probe frame design • Paper out alarm
• Support alarm review
Sensor
• 12-Crystal ultrasound transducer achieves a wider Linux OS
focal region for more uniform coverage at greater depths • Support operation with mouse and computer
than conventional 9-crystal. 12-crystal ultrasound design keyboard (option)
can also get good result even when the patient varies her • Multi-display mode to meet different clinical
position and shape requirement, including Fetal-parameter interface,
Maternal-parameter interface, Fetal/Maternal-parameter
• Optional waterproof FHR transducer for underwater interface, as well as big font, alarm review, ECG review,
birth trend table, trend graph and OxyCRG display.
• Event Marker for easy documentation of events and
kick counts. Auto-fetal-movement detector is also • NIBP self-test mode: including overpressure test,
available. static pressure test and air leakage test.
• Use of signal strength indicator to position the • On-screen scrolling for viewing stored fetal traces
ultrasound transducers at the optimum location on the • Generate ID automatically when register a new patient
patient • Support medical history search by patient ID, name
and mobile number
Printer • NST Timer
• Built-in high-speed thermal printer, printing width can be • Fetal Movement Profile (FMP) detects and
set to 112mm, 150mm, can meet both US standard automatically records gross fetal body movements
and European standard (Brand: SEIKO, Japan) • Heart rate offset mode allowing you to offset FHR2
± 5~30BPM.
• Support fast printing of stored trend • Support multi-language display
• Advanced Fischer NST Report (Fetal Health
Central System Report)
• Optional Build-in wireless network module, • Support online software upgrading by net/USB
supporting wired or wireless connection to the central • Optional patient data/NST Report backup by USB
monitoring station. in PDF format
Interface Related Product
Transducer socket
• US1 (FHR1)
• US2 (FHR 2)
• TOCO
• FM (Manual Fetal movement)
• ECG (Maternal ECG)
• TEMP (Maternal temperature)
• SPO2 (Maternal SpO2) • The monitor is compatible with Acoustic Fetal
• NIBP (Maternal NIBP) Stimulator, which use low frequency vibro-acoustic stimuli
(VAS) to “wake” the fetus, increasing the efficiency of
LAN / Central monitor system interface antepartum testing and improving retest consistency.
• The LAN port is for connecting the monitor to a central
monitor system network.
- Weight: 5.3kg(excluding accessories) - Measure method: Wide beam pulse doppler - Gain: ×0.25, ×0.50, ×1, ×2, ×4
Power Supply - FHR Measurement range:
- Respiration Rate: 0bpm, 6 ~ 150 bpm
- Voltage: AC100~240V, 50/60HZ 30 to 240 bpm (US Standard)
- Resolution: 1 bpm
Display 50 to 210 bpm (Europe Standard)
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Accuracy: ±1 bpm
- 12.1" color TFT LED (0-90° rotation) - Apnea Alarm: 10 ~ 60 s
- Intensity: <3 mW/cm2
- Resolution: 1024*768 pixels Maternal SpO2 (Digital Technic)
- Ultrasound frequency: 1MHz±3%
Battery (Built-in) - Measurement Range: 0 ~ 100 %
- Resolution: 1 bpm
- Type: Rechargeable lithium battery 14.8V/2200mAh - Resolution: 1 %
TOCO
- Charge Cycle: ≥500 times - Accuracy: ±2% (70% ~ 100%)
- Measurement method: Strain gauge sensor element
- Working time: 2 hours ±3 % (35% ~ 69%)
- Measure range: 0 ~ 100 units
Unspecified (0 ~ 34%)
- Resolution: 1 unit
Recorder (Built-in) Pulse Rate
- Nonlinear deviation : ≤±8%
- Method: Thermal printer - Range: 25~250bpm
- Baseline setting: 0,5,10,15, 20 can be selected
- Paper: Z-fold, thermosensitive - Accuracy: ±1% or ±1 bpm, whichever is greater
- Auto offset correction: 3 second after connecting the
- Paper width: 112 mm (4.41 in)/150 mm (5.91 in) - Resolution: 1bpm
transducer
- Printing speed: 1/2/3cm/min
- Auto zero adjust: TOCO value is set to zero negative
Maternal NIBP (MNIBP)
- Trace: Max. 4 tracks
following a negative Measure value for 5 seconds - Method: Oscillometric
- Recording way: Real-time Recording, Review Printing
Fetal Movement Recording - Measure mode Manual, Auto, STAT
Alarm - Measure Interval in AUTO Mode 1~480 min
- Automatic fetal movement (AFM): pulsed doppler
- Level: Low, medium and high - STAT mode cycle time: Keep 5 minutes, at 5
ultrasound
- Indication: Auditory, Visual, Delay of FHR Alarm seconds interval
- Automatic fetal movement autograph
Input Device - Measure and Alarm Range:
- Manual fetal movement marker (MFM)
- Touch screen (option) Systolic: 30~270 mmHg
Maternal ECG
- Knob (Standard) Diastolic: 10~220 mmHg
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL,
- Keypad input (Standard) Mean: 20~235 mmHg
AVF, V
- Mouse/ Keyboard input (option) - Static pressure accuracy ±3mmHg
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,
- USB port for patient data/NST report backup - Resolution: 1mmHg
40mm/mV, Auto
(option) - Accuracy: Maximum Mean error ±5mmHg
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
System Output & Extensible Maximum Standard deviation 8mmHg
- Accuracy: ±1bpm/ ±1%, whichever is greater
Interface - Resolution: 1 bpm
- Over pressure Protection: Dual protection via
- IEC60601-1 Approved, CE marking according to ST Measurement - Average Baseline FHR / Number of Acceleration /
Model AFM
Single Dual Signal Overlap 112mm 112mm 150mm 150mm Lithium
TOCO & NIBP, SpO2, PR ECG, TEMP, RESP
FHR FHR Alarm A type B type A type B type battery
MFM
FHR Transducer TOCO Transducer Event Marker Fetal Acoustic Stimulator Central Monitoring Station Reusable Transducer Belt NIBP Cuff and NIBP Tube SpO2 Transducer
112(A) mm Thermal Paper 112(B) mm Thermal Paper 150 (A) mm Thermal Paper
150 (B) mm Thermal Paper
Temperature (112mm×100mm×150p, (112mm×100mm×150p, (150mm×100mm×150p,
(150mm×100mm×150p,
Transducer (Skin / European Standard, USA Standard, 30-240 bpm) European Standard,
ECG Cables
USA Standard, 30-240bpm)
Rectal type) Trolley with Basket 30-210 bpm) 50-210bpm)
Wall-mount with basket
Standard Packing List:
Email: market@unicare-med.com
Web: www.unicare-med.com/en
Unicare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences resulting from the use of this publication.
November 2016