Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Technical Data Sheet

WP- SDC-H
Woltmann hot water meter with super dry dial

The VuAqua WP-SDC-H is a woltmann mechanical water meter with dry type dial counter suitable for
a variety of hot water distribution and industrial applications available in sizes DN50 (2”) to DN500 (20”).

Key Features
• Woltmann helix meter type (Bulk Meter) • Can be installed vertically or horizontally
• Replaceable ‘drop-in’ mechanism • DIN flanged connections (ANSI option)
• Approved: MID /OIML • Maximum pressure of 16 bar
• Dry dial (frost resistant) • Maximum temperature of 90°C (T90)
• Meter body material is epoxy coated cast iron • Pulse Output option: Vmax=24AC/DC, Imax=0.01A
• Tamper evident wire lock & seal
Dimensions

Standard flange under ISO 7005-2:1998(E) PN16


Size DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500
L 260 200 200 225 250 250 300 350 450 500 500 600 800
H 225 252 262 272 282 297 341 371 480 516 560 647 785
H1 303 339 349 359 369 384 428 458 576 603 603 723 838
G 360 400 400 400 400 400 500 500 710 730 730 830 930
D 150 165 185 200 220 250 285 340 405 460 520 580 715
D1 110 125 145 160 180 210 240 295 355 410 470 525 650
nxM 4xM16 8xM16 8xM20 12xM20 12xM24 16xM24 16xM27 20xM30
Additional flange selection under ISO 7005-2:1998(E) PN10. ASME B16.1-Class 125 working for B16.5-Class 150

Additional length options available:


Size DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500
250 250 200 300 430 500 500
L 270 260 270 360
310 300 483
413

Technical Data
Size DN DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500
R Q3/Q1 50 80
Q4 m /h 31.325
3
50 78.75 78.75 125 200 312.5 500 787.5 1250 1250 2000 3125
Q3 m3/h 25 40 63 63 100 160 250 400 630 1000 1000 1600 2500
Q2 m3/h 0.8 0.8 1.26 1.26 2 3.2 5 8 12.6 20 20 32 50
Q1 m3/h 0.5 0.5 0.7875 0.7875 1.25 2 3.125 5 7.875 12.5 12.5 20 31.25
Max. Reading m 3
999999.999 9999999.99 99999999.9
Min. Reading Litre 0.0005 0.005 0.05
Press Loss Class ΔP 10 16 10 10 10 16 10 10 10 10 10 10 10
Max. Pressure Bar 16
Max. Temperate °C 90 (T90)
Pressure Loss Curve

Max. Permissible Error


From Q1 inclusive up to but excluding Q2 is ± 5%
From Q2 inclusive up to and including Q4 is ±2% Distributed by:

Pulse Output
Pulse output option available on all sizes.
Pulse Output Capacity (m3/pulse):
DN40 to DN125: 0.1 or 1
DN150 to DN200: 1 or 10
DN250 to DN500: 10 or 100

Dial plate design

Meet the VuAqua family

You might also like