BY

Magellan Quick Programming Guide:


INSTALLER PROGRAMMING:

(ready status)
How to enter programming:
STEP 1: PRESS AND HOLD THE [0] KEY
STEP 2: ENTER THE [INSTALLER CODE] (DEFAULT: 0000).
STEP 3: ENTER 3-DIGIT [SECTION] YOU WISH TO PROGRAM.
STEP 4: ENTER [DATA] AS REQUIRED
STEP 5: PRESS THE [*] TO CLEAR DATA. PRESS THE [#] TO SAVE CHANGES.

[001] Zone Defi.


(001) (12xxxxx8)
Programming zones:
STEP 1: GET INTO PROG. MODE: (see above)
STEP 2: ENTER SECTION NUMBER (e.g: 001 = Zone 1)
STEP 3: ENTER THREE DIGITS FROM THE ZONE DEFINITION TABLE
(i.e. instant, follow (handover), entry)
STEP 4: SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE
(This table is a toggle ON/OFF feature.)
I.e. if key 2 is on = Bypassable zone, this means it is enabled.
If you want to disable it, press key 2, and the led will turn off. This disables that option.
STEP 5: PRESS [#] TO SAVE
*PANEL AUTOMATICALLY JUMPS TO NEXT ADDRESS IN ZONE PROGRAMMING
STEP 6: FOLLOW PROCEDURES FROM STEP 3 TO PROGRAM THE NEXT ZONE OR
PRESS [*] TWICE TO EXIT ZONE PROGRAMMING.
STEP 7: PRESS [EXIT] TO RETURN TO READY STATUS.

[060] Timers
(005)
System timers:
SECTION: [060] ENTRY DELAY 1 *045 SECS
SECTION: [062] EXIT DELAY *060 SECS
SECTION: [072] NUMBER OF RINGS *008 RINGS (* = default setting)
SECTION: [071] AUTO TEST REPORT DAYS *DISABLED (see page 2 for programming)
SECTION: [084] AUTO TEST REPORT TIME *DISABLED (see page 2 fo r programming)

1
[181] Code
(000000)
SECTION: [181] INSTALLER CODE (a 00 must be entered as the last two digits of a 4 digit installer code)

[021] TX Serial
(00000) Weak 00

Programming Wireless Transmitters:

(Wireless PIR’s, Reeds etc.)

STEP 1: GET INTO PROG MODE:


STEP 2: ENTER SECTION NUMBER (e.g: 021 = Zone 1)
STEP 3: ENTER 6 DIGIT SERIAL NUMER OF WIRELESS DEVICE
*PANEL AUTOMATICALLY JUMPS TO NEXT ADDRESS IN PROGRAMMING
STEP 4: FOLLOW PROCEDURES FROM STEP 3 TO PROGRAM THE NEXT ZONE OR
PRESS [*] TO EXIT PROGRAMMING
STEP 5: PRESS [EXIT] TO RETURN TO READY STATUS.

Central Report?
ok next exit

Personal Voice Dialing: (maximum of 2 x mobile phone numbers allowed)

STEP 1: PRESS [MENU] FROM READY STATUS


STEP 2: PRESS [4] TO ENTER SYSTEM SET-UP
STEP 3: PRESS [3] TO ENTER COMMUNICATOR SETTINGS
STEP 4: PRESS [NEXT] KEY TO SELECT VOICE REPORT
STEP 5: PRESS [OK] TO ENTER VOICE REPORT PROGRAMMING
STEP 6: PRESS [OK] TO ENTER MOBILE PHONE NUMBER
STEP 7: ENTER 1ST MOBILE PHONE NUMBER THEN PRESS [OK] TO SAVE
REPEAT STEP 7 TO ENTER 2ND MOBILE PHONE NUMBER OR GO TO STEP 8
STEP 8: PRESS [OK] TO RECORD ALARM MESSAGE
STEP 9: RECORD MESSAGE AFTER THE TONE AND PRESS [STOP] (e.g “home alarm is active”)
STEP 10: PRESS [PLAY] TO HEAR MESSAGE OR [NO] TO RE-RECORD OR [YES] TO EXIT
STEP 11: PRESS [EXIT] TWICE TO RETURN TO READY STATUS

Back to Base Dialing:


STEP 1: SECTION: [100] ENABLE OPTIONS [1], [2], [5], [6] ONLY (opening / closing, alarm / restore)
STEP 2: SECTION: [101] ENABLE OPTIONS [1], [2], [5], [6] ONLY (tamper / trouble)
STEP 3: SECTION: [102] ENABLE OPTIONS [1], [2] ONLY (special)
STEP 4: SECTION: [107] ENTER AN ACCOUNT NUMBER
STEP 5: SECTION: [111] ENTER PRIMARY TELEPHONE NUMBER
STEP 6: SECTION: [112] ENTER SECONDARY TELEPHONE NUMBER

Auto Test Reports:


STEP 1: SECTION: [071] ENTER 0 / 0 / 1 (DAILY) OR 0 / 0 / 7 (WEEKLY)
STEP 2: SECTION: [084] ENTER 0 / 3: 0 / 0 FOR 3:OO am TEST REPORT TIME

Local Alarm:
STEP 1: SECTION: [100] DISABLE ALL OPTIONS
STEP 2: SECTION: [101] DISABLE ALL OPTIONS
STEP 3: SECTION: [102] DISABLE ALL OPTIONS

2
USER PROGRAMMING:

(ready status)
Programming Wireless Transmitters:

(Remote Controls)

STEP 1: PRESS [MENU] FROM READY STATUS


STEP 2: PRESS [4] TO ENTER SYSTEM SET-UP
STEP 3: PRESS [2] TO ENTER USER PROFILES
STEP 4: PRESS [NEXT] KEY TO SELECT USER NUMBER OR
STEP 5: PRESS [OK] TO MODIFY SELECTED USER
STEP 6: ENTER [USER CODE] THEN PRESS [OK]
STEP 7: PRESS [NO] TO MODIFY LABEL
STEP 8: PRESS [YES] TO PROGRAM REMOTE
STEP 9: PRESS ANY HOLD BUTTON ON REMOTE TO LEARN IT IN.
STEP 10: PRESS [NO] TO EXIT PROGRAMMING OR
PRESS [YES] TO PROGRAM ANOTHER REMOTE AND RETURN TO STEP 4:
STEP 11: PRESS [EXIT] TWICE TO RETURN TO READY STATUS.

Modify Master
ok next exit

Programming Access Codes:

STEP 1: PRESS [MENU] FROM READY STATUS


STEP 2: PRESS [4] TO ENTER SYSTEM SET-UP
STEP 3: PRESS [2] TO ENTER USER PROFILES
STEP 4: PRESS [NEXT] KEY TO SELECT USER NUMBER OR
STEP 5: PRESS [OK] TO MODIFY SELECTED USER
STEP 6: ENTER [USER CODE] THEN PRESS [OK]
STEP 7: ENTER [USER CODE] AGAIN TO CONFIRM THEN PRESS [OK]
STEP 8: PRESS [NO] TO EXIT PROGRAMMING OR PRESS [YES] TO MODIFY USER LABEL
STEP 9: RECORD MESSAGE AFTER THE TONE AND PRESS [STOP] (e.g “John Smith”)
STEP 10: PRESS [PLAY] TO HEAR MESSAGE OR [NO] TO RE-RECORD OR [YES] TO EXIT
STEP 11: PRESS [YES] TO LEARN REMOTE OR [NO] TO EXIT PROGRAMMING
TO PROGRAM ANOTHER USER PRESS [YES] AND REPEAT STEP 4 ONWARDS OR
STEP 12: PRESS [NO] TO EXIT ACCESS CODE PROGRAMMING
STEP 13: PRESS [EXIT] TWICE TO RETURN TO READY STATUS

3
PGM PROGRAMMING:

PGM1 Strobe Activation:


Event Group # Sub-group #
[086] PGM1 Activation Event (__0_/_ 2_) (__0_/_6__)

Event Group # Sub-group #


[087] PGM1 De activation Event (__0_/_ 2_) (__1_/_1__)

[068] __0__/__0__/__0__ seconds (PGM1 timer)

PGM2 External Siren Activation:


Event Group # Sub-group #
[088] PGM2 Activation Event (__0_/_ 2_) (__0_/_4__)

Event Group # Sub-group #


[089] PGM2 De activation Event (__0_/_ 2_) (__0_/_7__)

[069] __0__/__0__/__0__ seconds (PGM2 timer)