Aircon 11
Aircon 11
Aircon 11
7C 2.5HP AIRCONDITIONING UNIT 3220 14.0 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
1 - 3.5mm² TW Cu. WIRE 25 mm Ǿ LQTFC COMPUTATION OF LOAD :
2 - 5.5mm² THHN/THWN Cu. WIRE
8C 2.5HP AIRCONDITIONING UNIT 3220 14.0 2P-30AT/50AF 230 V 1 - 3.5mm² TW Cu. WIRE 25 mm Ǿ LQTFC I = √3 (316+ 0.25 X14)
9C 2.5HP AIRCONDITIONING UNIT 3220 14.0 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
25 mm Ǿ LQTFC
=552.74 AMPERES
1 - 3.5mm² TW Cu. WIRE
10C 2.5HP AIRCONDITIONING UNIT 3220 14.0 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
25 mm Ǿ LQTFC USE:
1 - 3.5mm² TW Cu. WIRE
2.5HP AIRCONDITIONING UNIT 3220 2 - 5.5mm² THHN/THWN Cu. WIRE FEEDER: 6RUNS OF 150 mm² THHN/THWN 1 - 30mm² TW in 75mmØ uPVC
11C 14.0 2P-30AT/50AF 230 V 1 - 3.5mm² TW Cu. WIRE 25 mm Ǿ LQTFC
FOR MAIN BREAKER: 600AT/800AF, 3P, 240V, 60HZ, 25KAIC
2.5HP AIRCONDITIONING UNIT 3220 2 - 5.5mm² THHN/THWN Cu. WIRE
12C 14.0 2P-30AT/50AF 230 V 1 - 3.5mm² TW Cu. WIRE 25 mm Ǿ LQTFC
17C
18C
2.5HP AIRCONDITIONING UNIT
3220
14.0
14.0
2P-30AT/50AF
2P-30AT/50AF
230 V
230 V
2 - 5.5mm² THHN/THWN Cu. WIRE
1 - 3.5mm² TW Cu. WIRE
2 - 5.5mm² THHN/THWN Cu. WIRE
1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
25 mm Ǿ LQTFC
GENERAL NOTES AND SPECIFICATIONS
SCALE NTS
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
19C 14.0 1 - 3.5mm² TW Cu. WIRE 25 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
20C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
22C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
23C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
24C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
25C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
1.0HP AIRCONDITIONING UNIT 1840 2P-20AT/50AF 230 V 2 - 3.5mm² THHN/THWN Cu. WIRE
26C 8.00 1 - 3.5mm² TW Cu. WIRE
20 mm Ǿ LQTFC
2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE
28C 14.0 1 - 3.5mm² TW Cu. WIRE
25 mm Ǿ LQTFC
30C 2.5HP AIRCONDITIONING UNIT 3220 2P-30AT/50AF 230 V 2 - 5.5mm² THHN/THWN Cu. WIRE 25 mm Ǿ LQTFC
14.0 1 - 3.5mm² TW Cu. WIRE
3 - 125mm² THHN/THWN Cu. WIRE
T O T A L 140 134 140 3P-250AT/400AF 230 V 1 - 30mm² TW Cu. WIRE 70mm Ǿ uPVC
COMPUTATION OF LOAD :
I = √3 (140+ 0.25 X14)
=248.26 AMPERES
USE:
FEEDER: 3RUNS OF 125 mm² THHN/THWN 1 - 30mm² TW in 70mmØ uPVC
FOR MAIN BREAKER: 250AT/400AF, 3P, 240V, 60HZ, 15KAIC
PREPARED BY PROJECT PROFESSIONAL ELECTRICAL ENGINEER CONCURRED BY: RECOMMENDING APPROVAL APPROVED BY SHEET
REGISTERED ELECTRICAL ENGINEER GRADE SCHOOL PRINCIPAL PPPDMO HEAD UNIVERSITY PRESIDENT Checked by :
Dumlao Blvd, Bayombong, Nueva Vizcaya
DATE :