Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Atc Draw Pit Type B Twin Concrete Draw/Jointing Chamber (For Depth of Draw Pit Exceeing 850 MM) H 2161A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Heavy duty cast iron frame Cast iron frame & cover

Cast iron frame & cover


& cover see H2162 see ATC/HK/60
125
see ATC/HK/60 Footway level
Footway level
Carriageway
1 : 3 cement mortar
level

150
120

50
127
1 : 3 cement mortar

50

127

150 min.
1800 mox.

50
2 Nos. 127 x 76
Varies

18 x 13.36 kg R.S.J.

25 x 25 chamfer 50 50

450 min.
270

150 min.
100 12mm fall
200

SECTION E
-E F SECTION F
-F
50

270

200
E Notes :

1. See H2157 for general notes.


E
2. See H2160 for type A chamber
600 x 600
600 x 600
opening
opening
1000

200

A Typo in Section E-E amended Oct 13


200 200 PLAN Former Drg. No. H2036/6A
50

June 94
1870 with general revision
F (C.I. cover & frame omitted)
REF. REVISION SIGNATURE DATE

HIGHWAYS DEPARTMENT
ATC DRAW PIT -
TYPE B TWIN CONCRETE
REFERENCE DRAWING No. CAD

DRAW/JOINTING CHAMBER (FOR DEPTH OF Drg. No. ATC/HK/61

DRAW PIT EXCEEING 850 mm)


SCALE
H 2161A
1 : 20