HH200 Series Drive

HH200 Series Drive

High Performance
 More accurate motor autotuning  Multiple braking modes and instant
 Accurate rotating and static motor autotuning stopping
 Convenient debugging and easy operation
Dynamic Braking DC Braking Flux Braking
Rotating Autotuning Static Autotuning Configure No need to No need to
De-couple form the load No need to de-couple from braking configure configure
Applied to the situation the load applied when units and braking braking units
with high control accuracy rotating autotuning is not resistors units and and resistors
available resistors
Available in the Available in the Available in the
 Optimized V/F control situation of big situation when instant stop
inertia load and we start the situation with
frequent braking running motor big inertia load
after braking and and no frequent
in the situation braking
Stable current fluctuation when the load changes
when we keep
the moment
output after
Current
braking to zero
speed

Big braking Not available in Not available in


torque and the situation of the situation of
quick braking big inertia load or big inertia load
instant stop and frequent and
braking in high braking (the
Quick torque fluctuation when the load changes
speed running energy consumed
on the stator and
its cooling is
better than DC
Torque
braking)

Slight speed fluctuation when the load changes


Rotating Speed

Current

The current, torque and speed waveforms when sudden


loading or unloading in SVPWM control mode with 2 Hz
running frequency and full load.

 Perfect voltage and current control,


reduce the fault protection time Flux braking current waveform when the running frequency
is 50 Hz, deceleration time is 0.1s with full load in
asynchronous motor SVPWM control mode.
OC Fault
Adjust the output frequency to avoid over-current of the
inverter during acceleration
OV Fault
Adjust the output frequency to avoid over-voltage of the
DC bus during deceleration

02
Multi­function with Simple Operation
 Separate air­duct  Book structure
 Parallel installation
The separate air-duct prevents the contaminants into the
 Smaller installation space with low cost and beautiful
electronic parts/components and greatly improves the
appearance.
protective effect of the inverter, as well as its reliability and
service life, to adapt various complicated site
environments. It can also facilitate the heat-releasing in
control cabinets and the heat-releasing design of the
customer.

 Multiple installation modes  The rivet design ensures reliable


1.5~22 kW: Wall mounting and flange mounting integration connection
 Greener proper grounding
 Stronger corrosion-resistance excellent EMC
 performance
Flange mounting

Wall mounting

Rivet
 C3 input filter (standard
Flange Mounting

configuration) and C2 filter


Wall Mounting
(optional)
C3 input filter is embedded in the factory to meet different
application requirements, save installation space and
avoid electromagnetic interference caused by incorrect  Smaller size
selection and site installation.
Due to the thermal simulation and advanced modularized
design, the size of our product is reduced greatly.

Conduction interference test

Remarks:
C2 filter: EMC performance of the drive achieves the
limited usage requirement in civil environment.
C3 filter: EMC performance of the drive achieves the
limited usage requirement in industrial environment.

03 www.hitachi-hirel.com
HH200 Series Drive

 Various external interfaces and  High performance keypad


swappable terminal board
convenient for replacement and
maintenance

External keypad
Terminals Quantity Features
ON-OFF 8 External LED keypad is standard and detachable in drives
input 1 kHz NPN and PNP
channels greater than 18.5 kW.
High
speed 1 For drives less than 15 kW, LED keypad is not detachable.
pulse 50 kHz NPN and PNP For detachable option please contact local Hitachi sales
channels
input office.
Analog 3 Al1, Al2 0~10 V / 0~220 mA
input channels Al3 -10~10 V
ON-OFF 1 Max. output frequency: 1 kHz
output channels
High
speed 1 Max. output frequency: 50 kHz
pulse channels
output
Analog 2
0~10 V, 0~20 mA
output channels
Relay 2 3 A / 250 V AC, 1 A / 30 V DC,
output channels NO+NC

The standard LED keypad supports parameters loading


and unloading with Max. length of 200 m and digital
potentiometer.

 Embedded braking units of


1.5­30 kW drive
Reduce the occupied space and decrease the cost

Embedded Braking Unit

200
Embedded Braking Unit
HH

0 0.751.5 15/18P 30/37P

04
 Supporting common DC bus
Reduce the power lost on DBR
Note the impact current and the capacity of the input AC system
HH200 series drive

400 VAC Input

HH200 series drive HH200 series drive

 Available on DC power supply

DC Input

HH200 series drive

Advanced Thermal Technology makes Wide Voltage Range meets the


exact Thermal Design requirement of Grid Environment

05 www.hitachi-hirel.com
HH200 Series Drive

Applications

Air Compressors Plastic Machinery

Petroleum Mining

HVAC and Water Supply Fan and Water Pumps

06
Technical Specifications
Function Specification
Input Voltage (V) AC 3 ph 380 V (-15%)~440 V (+10%)
Input

50 Hz or 60 Hz
Input Frequency (Hz)
Allowed range. 47~63 Hz
Technical Control Output

Output Voltage (V) 0~input voltage

Output Frequency (Hz) 0~400 Hz


Control Mode SVPWM
Motor Type Asynchronous motor
Feature

Speed-adjusting Ratio Asynchronous motor 1:100


Starting Torque Asynchronous motor: 0.5 Hz / 150%
150% of rated current 60 seconds
Overload Capability P type:
120% of rated current 60 seconds

Digital setting, analog setting, pulse frequency setting, multi-step speed


Running Control

Frequency Setting running setting, simple PLC setting, PID setting, MODBUS communication
setting. Realize the shifting between the set combination and set channel.
Feature

Auto Voltage Adjustmen Keep a stable voltage automatically when the grid voltage fluctuates
Provide over 30 fault protection functions: overcurrent, overvoltage,
Fault Protection undervoltage, overheating, phase failure and overload, etc.
Speed Tracking Restart the rotating motor smoothly
Terminal Analog
Input Resolution 10 mV

Terminal Switch
2 ms
Input Resolution
Peripheral Interface

Analog Input 2 channels (Al1, Al2) 0~10 V / 0-20 mA and 1 channel (Al3) -10~10 V
Analog Output 2 channels (A01, A02) 0~10 V / 0~20 mA
8 channels common input, the Max. frequency: 1 kHz
Digital Input
1 channel high speed pulse input, the Max. frequency: 50 kHz
1 channel high speed pulse output, the Max. frequency: 50 kHz;
Digital Output
1 channel Y terminal open collector output
2 channels programmable relay output
RO1A NO, RO1B NC, RO1C common terminal
Relay Output RO2A NO, RO2B NC, RO2C common terminal
Contactor capability: 3A / AC 250 V,1A / DC 30 V
Mountable Method Wall, flange and floor mountable
Temperature of the
-10~50°C, derate above 40°C
Running Environment
Ingress Protection IP20
Others

Cooling Air-cooling
Built-in braking unit for below 30 / 37 P (including 30 / 37 P)
Braking Unit
External braking unit for others
Braking Resistor Optional external configuration
Built-in C3 filter: meet the degree requirement of IEC61800-3 C3
EMC Filter External filter:meet the degree requirement of IEC61800-3 C2

07 www.hitachi-hirel.com
HH200 Series Drive

Wirings
Wiring diagram of the main circuit

Wiring diagram of the control circuit

HH200 series drive

08
Power Ratings
I continuous (A) I continuous (A)
Drive P (kW) Drive P (kW)
OL­ 150% for OL­ 120% for
Model Number Model Number
1 min. 1 min.
HH200-0R7A-4 2.5 0.7 HH200-5R5AP-4 14 5.5
HH200-1R5A-4 3.7 1.5 HH200-7R5AP-4 18.5 7.5
HH200-2R2A-4 5 2.2 HH200-110AP-4 25 11
HH200-4R0A-4 9.5 4 HH200-150AP-4 32 15
HH200-5R5A-4 14 5.5 HH200-185AP-4 38 18.5
HH200-7R5A-4 18.5 7.5 HH200-220AP-4 45 22
HH200-110A-4 25 11 HH200-300AP-4 60 30
HH200-150A-4 32 15
HH200-185A-4 38 18.5
HH200-220A-4 45 22

Type Designation Key

HH200 ­ 2R2A ­ 4 HH200 ­ 2R2AP ­ 5


1 2 3 4 1 2 3 4 5

Sign Detailed description of the sign Sign Detailed description of the sign

1 Drive Series Name 1 Drive Series Name

2 Power Rating in kW 2 Power Rating in kW

3 A - Series Identifier 3 A - Series Identifier

4 Voltage Class 4-400 V Class 4 P - Overload is 120% for 1 min.

5 Voltage Class 4-400 V Class

09 www.hitachi-hirel.com
HH200 Series Drive

Dimensions
Installation dimension when wall mounting
Installation
Drive Model W1 W2 H1 H2 D1
Hole
1.5~2.2 kW 126 115 186 175 174.5 5
4~5.5 kW 146 131 256 243.5 181 6
7.5~15 kW 170 151 320 303.5 216 6
18.5 kW 230 210 342 311 216 6
22~30 kW 255 237 407 384 245 7

Installation dimension when flange mounting


Installation
Drive Model W1 W2 W3 W4 H1 H2 H3 H4 D1 D2
Hole
1.5~2.2 kW 150 115 130 7.5 234 220 190 13.5 155 65.5 5
4~5.5 kW 170 131 150 9.5 292 276 260 6 167 84.5 6
7.5~15 kW 191 151 174 11.5 370 351 324 15 196 113 6
18.5 kW 250 210 234 12 375 356 334 10 216 108 6
22~30 kW 275 237 259 11 445 426 404 10 245 119 7

Installation Diagram
Wall mounting for 1.5~30 kW drive

10
Flange mounting for 1.5~30 kW drive

Keypad Dimension

11 www.hitachi-hirel.com
Global &
Pan India Presence

USA
Japan
Middle
East
India

South East Asia


Africa

Australia

Jammu & Kashmir

Jammu Mandi
Amritsar Himachal
Ludhiana Pradesh
Chandigarh
Dehradun
Punjab Uttara Moradabad
Haryana khand
Hisar Lucknow Siliguri
Gorakhpur Guwahati
Noida Indore
Kanpur Bhopal Allahabad
Jaipur Gwalior Muzzafarpur
Gopalganj Arunachal Pradesh
Ajmer Uttar Ranchi
Jodhpur
Udaipur Pradesh Jorhat
Barmer Rajasthan
Gandhinagar Bihar Meghalaya Sibsagar
Ahmedabad Sasan
Patna
Mehsana Jharkhand Korba
Sanand Bokaro Agartala
Mundra Madhya Pradesh West
Gujarat Bengal
Jamnagar Kolkata
Rajkot
Baroda Jamshedpur
Ankleshwar Jajpur
Angul
Surat Chattisgarh Bilaspur
Vapi Orisaa Cuttak
Bhubaneswar
Nashik Mumbai Maharashtra Raipur
Pune Bhilai
Hyderabad
Nagpur
Andhra Vizag
Belgaum
Rajahmundry
Pradesh
Bellary
Karnataka Kadapa
Udipi
Bangaluru Manufacturing Plant
HH200 Series / 08 / 16 / Ver.0.1 / Corp. Mktg. / India l Spotlight - 079 3002 2324

Chennai
Mangalore
Coimbatore Corporate Office
Palakkad Karaikal
Tamil Nadu
Kerala Tiruneveli Branch Office
Thiruvananthapuram
Service Center

Hitachi Hi­Rel Power Electronics Pvt. Ltd.


Sanand Works
SM 3 & 4, Sanand - II GIDC, Industrial Estate, Bol Village, Sanand - 382 110 Gujarat, India.
Phone: +91-2717-678 777, Fax: +91-2717-678 700
e­gallery
Email: ho_drives@hitachi-hirel.com, contact@hitachi-hirel.com
Web: www.hitachi-hirel.com

In the spirit of continuous improvement, specifications are subject to change without notice.