1.

50

6 - 16MM DIA. VERTICAL


BARS

2 SETS - 10MM DIA. LATERAL TIES


SPACED AT 3 @ 0.05, 10@ 0.075, 5 @
0.1 and REST @ 0.15 M ON CENTER

1.50
7- 16MM DIA. RSB ON CENTER
BOTHWAYS

A B
A B
A B 5.00 A B
5.00
5.00
2.70 0.20 2.10
5.00 PLAN
GB2 2B1 RB
3 3 3 3
WF

WF

FC1 FC1
2.50

2B1

2B3

2B1
2.50

2.50

RB

RB
GB2

GB2
S2

2.50
8- 16MM DIA. VERTICAL
BARS

GB2 2B2 RB 2-SETS 10MM DIA. LATERAL TIES


2 2 2 2 SPACED AT 3 @ 0.05, 3@ 0.10, 3 @
6.00

6.00
6.00
STAIR WELL S2 0.15 and REST @ 0.20 M ON CENTER
FC1 FC1
NGL 10mm dia.RSB thread reif. sp.@250mm

2B1
3.50

3.50

3.50

RB

RB
GB2

GB2
3.50
10mm dia.RSB nosing bars

2B1
2B1

2B3
S2
7 - 16MM DIA. RSB ON CENTER

VERIFY
1.45 METERS

1.10
BOTHWAYS 16mm dia.RSB @150mm
2B2 RB o.c, top & bottom bars
GB1
1 1 1 1 NGL

2B1C

2B1C
0.90
S1 0.00
FC1 FC1

0.50
2B1 16mm dia.RSB @200mm
o.c.b.w

0.30

0.20
SECTION

GRADE BEAM SECOND FLOOR


FOUNDATION PLAN FRAMING PLAN FRAMING PLAN ROOF BEAM PLAN FOOTING DETAILS STAIR ELEV
SCALE 1:75 MTRS. SCALE 1:100 MTRS. SCALE 1:100 MTRS. SCALE 1:100 MTRS. SCALE 1:30 MTRS. SCALE 1:30 MTRS.

0.5MM LONG SPAN RIB TYPE ROOFING SHEET


0.05
1.5MM X 50MM X 75MM C-PURLINS SPACED
@ 0.60M ON CENTER
P 1.5MM X 50MM X 150MM C-
0.60
5MM X 50MM X 100MM CHANNEL BAR PURLINS
0.60
A B
5MM X 38MM X 38MM ANGLE BAR 5MM X 38MM X 38MM ANGLE BAR SPACED
CLEATS
@ 0.60M ON CENTER 5.00

0.15
0.40 0.60 0.99 1.75 1.75 1.50 0.99
FULLY WELD

0.99
5MM X 38MM X 38MM ANGLE BAR
0.40

10 MM DIA. HORIZONTAL
BARS SPACED AT EVERY 0.15
SPACED @ 0.60M ON CENTER 3 2"x6"x1.5mm C-purlins rafter truss
3 LAYERS OF CHB SECTION "P"
10 MM DIA. HORIZONTAL 2"x3"x1.2mm C-purlins sp.@ 0.60m
RAFTER DETAIL
0.40

3-10 MM DIA. CONTINOUS BARS BARS SPACED AT EVERY


SPACED AT 0.15 ON CENTER 3 LAYERS OF CHB SCALE 1:20 MTRS.

4"X8"X16"

2
0.40

CONCRETE HOLLOW
10 MM DIA. VERTICAL BARS BLOCKS
SPACED AT 0.60M ON CENTER

7.00
4"X8"X16" 10 MM DIA. VERTICAL BARS TOP BAR BOTTOM BARS
0.40

SPACED AT 0.60M ON CENTER


CONCRETE HOLLOW MARK WIDTH HEIGHT STIRRUPS LOCATION
BLOCKS
3-10 MM DIA. CONTINOUS BARS
(mm) (mm) SUPPORT MIDSPAN SUPPORT MIDSPAN
SPACED AT 0.15 ON CENTER
10MM DIA. RSB 10mm∅ BARS SPACED AT 1@50mm, 3@75mm,
0.40

GB1 200 350 5 - 16mm∅


∅ 3 - 16mm∅
∅ 5 - 16mm∅
∅ 2- 16mm∅
∅ 5@100mm, THE REST @150mm O.C GROUND FLOOR
0.40

SPACED AT 0.40M
ON CENTER
0.65

10MM DIA. RSB 10mm∅ BARS SPACED AT 1@50mm, 3@75mm,


SPACED AT 0.40M GB2 200 350 4 - 16mm∅
∅ 2 - 16mm∅
∅ 4- 16mm∅
∅ 2- 16mm∅
∅ 5@100mm, THE REST @150mm O.C GROUND FLOOR
0.25

ON CENTER
0.40

10mm∅ BARS SPACED AT 1@50mm, 3@75mm,


2B1 300 400 6 - 16mm∅
∅ 3 - 16mm∅
∅ 3 - 16mm∅
∅ 6- 16mm∅
∅ SECOND FLOOR
0.40
5@100mm, THE REST @150mm O.C
1

0.99
10mm∅ BARS SPACED AT 1@50mm, 3@75mm,
2B1C 250 350 6 - 16mm∅
∅ 6 - 16mm∅
∅ 3- 16mm∅
∅ 3- 16mm∅
∅ 5@100mm, THE REST @150mm O.C SECOND FLOOR
10mm∅ BARS SPACED AT 1@50mm, 3@75mm,
2B2 250 400 6 - 16mm∅
∅ 3 - 16mm∅
∅ 3 - 16mm∅
∅ 6- 16mm∅
∅ 5@100mm, THE REST @150mm O.C SECOND FLOOR
PLAN SECTION 2B3 200 250 2 - 16mm∅
∅ 2 - 16mm∅
∅ 2 - 16mm∅
∅ 2- 16mm∅

10mm∅ BARS SPACED AT 1@50mm, 3@75mm,
5@100mm, THE REST @150mm O.C SECOND FLOOR
10mm∅ BARS SPACED AT 1@50mm, 3@75mm,
RB 200 300 3 - 16mm∅
∅ 2 - 16mm∅
∅ 2 - 16mm∅
∅ 3- 16mm∅
∅ 5@100mm, THE REST @150mm O.C ROOF

WALL FOOTING DETAIL BEAM SCHEDULE ROOF FRAMING PLAN


SCALE 1:300 MTRS. SCALE 1:75 MTRS. SCALE 1:75 MTRS.

LOGO: IMPORTANT PROJECT TITLE: CONFORME: ISSUE NO: SHEET CONTENTS: SHEET NO:

ARTICLE IV - SECTION 33, RA 9266


PROPOSED: DATE ISSUED: AS SHOWN
Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are
the intellectual property and documents of the architect, whether the object for which they are made is executed or not.
It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
ENGR. KENNETH L. EDRA
"TWO STOREY REDENTIAL" DRAWN BY:
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said
documents.
All architects shall incorporate this provision in all contract documents and other instruments of service.
Mrs. Shella Marie R. Briones
Presidential Decree No. 49 OWNER CHECKED BY:
"PROTECTION OF INTELLECTUAL PROPERTY"
WORKS OF ART, ARCHITECTURE, MODELS AND DESIGNS ARE CREATIVE WORKS AND CONSIDERED AS PART
REG: 0129456 TIN: 448-390-296
OF THE INTELLECTUAL PROPERTY OF THE ARCHITECT OR AUTHOR DULY PROTECTED BY AND UNDER P.D.
PTR: 0350452 ISSD ON: 01/15/2024 AT: LOCATION: Brgy. 23, Sarrat, Ilocos Norte ADDRESS: Brgy. 23, Sarrat, Ilocos Norte DESIGNED BY:
No. 49. BATAC CITY
STRUCTURAL NOTES AND SPECIFICATIONS: COLUMN:
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR 1. WHERE COLUMNS CHANGE IN SIZE, VERTICAL REINFORCEMENTS SHALL BE OFFSET AT A SLOPE NOT
NOTED MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. MORE THAN 1 IN 6. PROVIDE TRANSVERSE REINFORCEMENT (JOINT HOOPS) AS PER FIGURE PROVIDED IN STRUCTURAL STEEL:
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS. MISCELLANEOUS SHEET NO. 2.
IRON, PRE-CAST CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL PRIOR TO 2. LAP SPLICES, WHEN REQUIRED, ARE PERMITTED ONLY WITHIN THE CENTER HALF OF THE COLUMN 1. ALL STRUCTURAL STEEL SECTIONS SHOWN IN THE DRAWINGS SHALL CONFORM TO ASTM SPECIFICATIONS
PURCHASE, FABRICATION AND INSTALLATION. LENGHT AND SHALL BE PROPORTIONED AS TENSION SPLICES. FOR A-36 STEEL (Fy= 36,000 psi),
IN NO CASE SHALL THE LAP SPLICE BE LOCATED CLOSER THAT A DISTANCE EQUAL TO THE MAXIMUM 2. ALL WELDED CONNECTIONS MUST DEVELOP THE FULL STRENGHT OF THE MEMBERS.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN. CHECK WITH SANITARY, 3. FABRICATION AND WELDING SHALL BE GOVERNED BY APPLICABLE PROVISIONS OF THE LATEST AISC OR
MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC., TO BE EMBEDDED IN COLUMN DIMENSION FROM THE FACE OF THE BEAM-COLUMN JOINT. PROVIDE EXTRA TRANSVERSE
REINFORCEMENT OF THE SAME SIZE ARRANGEMENT INDICATED IN THE COLUMN SCHEDULE SPACED AT AWS STANDARDS.
CONCRETE. 4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHECK ACTUAL FIELD CONDITIONS PRIOR TO
MOST ONE-FOURTH OF THE MINIMUM COLUMN DIMENSION THROUGHOUT THE LENGHT OF THE SPLICE OR
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING AND BRACING OF PREPARATION OF FABRICATION (SHOP) DRAWINGS.
100mm.
THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL PREPARE FABRICATION (SHOP) DRAWINGS OF ALL STRUCTURAL STEEL
3. FOR ALL TIED COLUMNS, PROVIDE TRANSVERSE REINFORCEMENTS OF THE SAME SIZE AND
MEMBERS BASED ON THE DESIGNS FOR APPROVAL OF THE ENGINEER PRIOR TO FABRICATION.
FOOTING: ARRANGEMENT INDICATED IN THE COLUMN SECTION SCHEDULE AND SPACED NO GREATER THAN ONE
QUARTER THE MINIMUM COLUMN SECTION DIMENSION NOR 100mm. OVER A DISTANCE FROM EACH JOINT
6. ALL DOUBLE-ANGLE STRUCTURAL MEMBERS SHAL BE PROVIDED WITH GUSSET PLATES AS SHOWN IN
THE DRAWINGS.
1. FOOTINGS WERE DESIGNED TO REST ON SOIL WITH AN ASSUMED BEARING CAPACITY OF 150KPA.
2. NO FOOTING SHALL REST ON FILL. FACE OF LESS NOT LESS THAN THE LARGER OF THE MAXIMUM COLUMN SECTION DIMENSION, OR ONE S 7. ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL RECEIVE AT LEAST ONE COAT OF RED LEAD PAINT.
3. MINIMUM CONCRETE PROTECTION SHALL BE .075M CLEAR FOR CONCRETE DEPOSITED AGAINST THE SIXTH OF THE CLEAR HEIGHT OF THE COLUMN OR 450mm.
GROUND AND 0.05M FOR CONCRETE DEPOSITED AGAINST THE FRAMEWORK. 4. UNLESS OTHERWISE DETAILED, TYPICAL BAR DETAILS FOR TIED COLUMNS ARE AS SHOWN IN FIGURE
PROVIDED IN SHEET. NO. 2.

MASONRY AND CONCRETE BLOCKS:


CONCRETE MIXES AND PLACINGS:
1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80
1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDER COMPRESSIVE STRENGHT OF PCF. FOR LOAD BEARING TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGHT OF 4.83 Mpa
CONCRETE 2. PROVIDE 1-16∅
∅ VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS AND EACH SIDE OF
ARE AS FOLLOWS: MASONRY WALL OPENING.
LOCATION STREGHT AGGREGATE SIZE
SHALL BE DEVELOPED.
FOUNDATION, PILE CAP 3000 psi 3/4 IN (19mm)
REINFORCING STEEL BARS 3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200mm) ON EACH SIDE OF MASONRY WALL OPENING.
3000 psi 3/4 IN (19mm)
1. ALL REINFORCING STEEL SHALL BE NEW BILLET, HOT ROLLED, WELDABLE, DEFORMED BARS CONFORMING 4. UNLESS OTHERWISE INDICATED IN THE PLANS, WALL REINFORCEMENT SHALL BE AS FOLLOWS:
BEAMS, GIRDERS TO THE SPECIFICATIONS OF PNS 49; 1986 (ASTM 615), Fy= 60,000 psi (413.79 Mpa) FOR SIZES >10∅

3000 psi IN THE PLANS OR AS ORDERED BY THE STRUCTURAL ENGINEER BUT IN NO CASE LESS THAN 19mm
COLUMN, STAIR 3/4 IN (19mm) AND Fy = 40,000 psi (275.86 Mpa) FOR SIZES ≤ 10∅
∅. FOR EVERY 3.0M OF FREE SPAN.
SUSPENDED SLAB 3000 psi 3/4 IN (19mm) 2. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, AND SPACED
SHALL THERE LESS THAN TWO (2) SEPERATORS BETWEEN LAYERS OF BARS.
SHEARWALL/RET. WALL 3000 psi 3/4 IN (19mm) IN FORMS, SECURED IN THE REQUIRED LOCATION IN ACCORDANCE WITH THE PROCEDURES AND ABOVE THOSE IN THE BOTTOM LAYER.
REQUIREMENTS OUTLINED IN THE LATEST EDITION OF THE BUILDING CODE AND THE MANUAL OF
SLAB ON GRADE 2500 psi 3/4 IN (19mm) STANDARD PRACTICE FOR DETAILED REINFORCED CONCRETE STRUCTURES.
3. ALL REINFORCING STEEL BARS SHALL BE THOUROUGHLY CLEANED OF ALL LOOSE RUST, SOIL OR OTHER
2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED ACCORDING TO THE ACI STANDARDS. CORROSIVE MATERIAL IMMEDIATELY PRIOR TO PLACING OF CONCRETE.
3. STRIPPING OF FORMS AND SHORES SHALL BE AS FOLLOWS:

FOUNDATION 1 DAY
BEAMS, GIRDERS 21 DAYS
CONCRETE HOLLOW BLOCKS REINFORCEMENT
COLUMN & WALLS 3 DAYS
SUSPENDED SLAB 17 DAYS REINFORCEMENT NOTES
THICKNESS
3 DAYS HORIZONTAL VERTICAL A. MIN. LAP SPLICE = 0.25M
SHEARWALL/RET. WALL
17 DAYS 0.076m 10∅
∅ @ 0.60m O.C. 10∅
∅ @ 0.60m O.C. B. PROVIDE RIGHT ANGLE REINFORCEMENT
RC STAIRS AT CORNER 0.90M LONG.
0.102m 10∅
∅ @ 0.60m O.C. 10∅
∅ @ 0.60m O.C.
CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, RE-HANDLING, OR C. WHERE CHB WALLS ADJOINING COLUMN, R.C. BEAM,
FLOWING. PLACING OF CONCRETE SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS, OR WHEEL 0.152m ∅ @ 0.60m O.C.
10∅ ∅ @ 0.60m O.C.
10∅ WALL DOWEL W/ SAME SIZE AS VERTICAL OR
BARROWS. NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUGGIES, HORIZONTAL REINFORCEMENT SHALL BE PROVIDED.
WHELL BARROWS, OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED 6.0M IN AGGREGATE LENGHT. 0.208m 10∅
∅ @ 0.60m O.C. 10∅
∅ @ 0.60m O.C.
NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS, UNLESS
AUTHORIZED IN WRITING BY THE DESIGNERS AND ONLY FOR USUAL CONDITIONS WHERE VIBRATOR IS
EXTREMELY DIFFICULT TO ACCOMPLISH.
SCHEDULE OF SLABS

DESCRIPTION ALONG LONG SPAN ALONG SHORT SPAN


BEAMS AND GIRDERS: BOT. BOT. BOT.
EXTRA EXTRA
HANGER BENT BOT. BARS BARS HANGER BENT BARS BARS
TOP TOP
MARK TYPE t(mm) BARS BARS @ MIDSPAN @ BARS BARS @ @
1. UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AT LEAST 6mm BARS BARS
SUPPORT MIDSPAN SUPPORT
FOR EVERY 3.0M OF SPAN EXCECPT FOR CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED
A B C D E F G H I J
2. IF THERE ARE TWO OR MORE LAYERS OF LONGITUDINAL REINFORCING BARS IN A BEAM OR ORDER, USE
SEPERATORS OF A SIZE NOT LESS THAN 25mm BARS SPACED ABOUT 0.90M ON CENTER. IN NO CASE S1 ONE-WAY 100 10mm @0.3m N.A. N.A. 10mm @0.1m 10mm @0.2m N.A. 10mm @0.2m 10mm @0.2m 10mm @0.1m 10mm @0.2m
3. LONGITUDINAL REINFORCING BARFS SHALL BE PLACED SYMMETRICALLY ABOUT THE VERTICAL CENTER
LINE OF THE BEAM OR GIRDER SECTION WHERE POSSIBLE WITH UPPER LAYER BARS PLACED DIRECTLY S2 TWO-WAY 100
10mm @0.3m 10mm @0.2m 10mm @0.2m 10mm @0.1m 10mm @0.2m N.A. 10mm @0.2m 10mm @0.2m 10mm @0.1m 10mm @0.2m
4. MINIMUM CONCRETE PROTECTION OF REINFORCING BARS SHALL BE 38mm,
5. BEAM REINFORCING BARS BOTH TOP AND BOTTOM TERMINATING IN A WALL SHALL EXTEND AT THE
NOTE: SPACING OF BENT BARS IS ALTERNATE WITH THAT OF THE EXTRA TOP BARS.
MOST 50mm FROM THE FAR FACE OF THE WALL AND SHALL TERMINATE IN A STANDARD 90° HOOK.
6. BEAM REINFORCING BARS BOT TOP AND BOTTOM TERMINATING IN A COLUMN, SHALL EXTERND TO THE
FAR FACE OF THE CONFINED CONCRETE CORE OF THE COLUMN AND TERMINATED BY A STANDARD
90° HOOK. LONG SPAN
7. GENERALLY NO LAP SLPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS AT POINTS WHERE LONG SPAN
WITHIN THE JOINTS OR WITHIN THE DISTANCE EQUAL TO TWICE THE DEPTH OF THE MEMBER FROM THE E
FACE OF THE JOINT.
CRITICAL BENDING STRESSES OCCUR. IN ADDITION, FOR GIRDERS, NO LAP SPLICE SHALL BE LOCATED
8. PROVIDE LAP SPLICES ON GIRDER WITH HOOP REINFORCEMENT OVER THE LENGHT OF THE LAPPED
BARS SPACED NO FARTHER THAN ONE-FOURTH OF THE NOMINAL DEPTH OR 100mm. G H

SHORT SPAN
9. SEE MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ALL SUSPENDED PIPE G H F B

SHORT SPAN
AND EMBEODED PIPINGS, CONDUITS, DUCTWORKS, ETC.

I D
I
STANDARD HOOKS STIRRUP AND TIE-HOOKS
A A C
D 180 DEG 90 DEG D 90 DEG 135 DEG J
BAR SIZE BAR SIZE D J
(MM) (MM)
A OR G J A OR G A OR G A OR G H
10∅
∅ 60 125 60 150 10∅
∅ 40 105 105 65
12∅
∅ 80 150 105 200 12∅
∅ 50 115 115 80
16∅
∅ 95 175 130 250
20∅
∅ 125 225 175 350 ONE-WAY SLAB DETAIL (S1) TWO-WAY SLAB DETAIL (S2)
25∅
∅ 155 275 205 425 SCALE 1:80 SCALE 1:80
32∅
∅ 275 425 335 550

LOGO: IMPORTANT PROJECT TITLE: CONFORME: ISSUE NO: SHEET CONTENTS: SHEET NO:

ARTICLE IV - SECTION 33, RA 9266


PROPOSED: DATE ISSUED: AS SHOWN
Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are
the intellectual property and documents of the architect, whether the object for which they are made is executed or not.
It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
ENGR. KENNETH L. EDRA
"TWO STOREY REDENTIAL" DRAWN BY:
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said
documents.
All architects shall incorporate this provision in all contract documents and other instruments of service.
Mrs. Shella Marie R. Briones
Presidential Decree No. 49 OWNER CHECKED BY:
"PROTECTION OF INTELLECTUAL PROPERTY"
WORKS OF ART, ARCHITECTURE, MODELS AND DESIGNS ARE CREATIVE WORKS AND CONSIDERED AS PART
REG: 0129456 TIN: 448-390-296
OF THE INTELLECTUAL PROPERTY OF THE ARCHITECT OR AUTHOR DULY PROTECTED BY AND UNDER P.D.
PTR: 0350452 ISSD ON: 01/15/2024 AT: LOCATION: Brgy. 23, Sarrat, Ilocos Norte ADDRESS: Brgy. 23, Sarrat, Ilocos Norte DESIGNED BY:
No. 49. BATAC CITY