You are on page 1of 11

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR5863-01
January 2015

320D2 and 323D2 Excavator


Hydraulic System - Attachment
320D2: 323D2:
LCA1-UP XBK1-UP
PBB1-UP TDT1-UP
NBF1-UP KBX1-UP
RAR1-UP
KBS1-UP
SDZ1-UP

Quick Coupler

© 2015 Caterpillar, All Rights Reserved Printed in U.S.A.


COMPONENT TABLE

Component Locations
Part Machine Schematic
Description
Number Location Location
Accumulator Gp - Hydraulic (Charged) 169-6981 1 B-8
Filter & Valve Gp - Pilot (Hydraulic Oil) 158-8987 2 A-5
Filter Gp - Oil (Hydraulic Return) 188-4140 3 A-8
Filter Gp - Oil (Hydraulic, Case Drain) 289-8194 4 B-6
Manifold Gp - Control (Pilot Oil Supply) 215-5037 5 C-9
Motor Gp - Swing 334-9968 6 G-13
Motor Gp - Travel (LH) 209-5992 7 D-13
Motor Gp - Travel (RH) 209-5992 8 D-11
Pump Gp - Main Hydraulic 376-8862 9 C-4
Sensor As - Pressure (Drive Pump) 366-9312 10 A-5
Sensor As - Pressure (Idler Pump) 366-9312 11 C-6
Swivel Gp 234-4440 12 A-12
Valve Gp - Check 369-8420 13 A-9
Valve Gp - Load Control (Boom Drift Red, Line Relief) 255-5683 14 G-8
Valve Gp - Load Control (Stick Drift Red, Line Relief) 255-5680 15 G-2
Valve Gp - Main Control ( Standard) 259-7464 16 F-11
Valve Gp - Main Control (Heavy - Lift) 285-1323 17 F-11
Valve Gp - Pilot (Joystick) (LH) 297-0533 18 J-14
Valve Gp - Pilot (Joystick) (RH) 297-0532 19 I-11
Valve Gp - Pilot (Travel) 310-0414 20 J-9
Valve Gp - Pressure Reducing (Boom, Swing Priority) 310-0210 21 C-7
Valve Gp - Shuttle 169-6974 22 D-8
Valve Gp - Shuttle (Cab) 185-0462 23 H-12
Valve Gp - Solenoid (Heavy Lift) 352-7176 24 D-5
Valve Gp - Swing Cushion (Fine Swing) 322-8716 25 E-14
Valve Gp - Travel Counterbalance (LH) 322-8714 26 A-14
Valve Gp - Travel Counterbalance (RH) 322-8714 27 A-11
Attachment: Quick Coupler
Valve Gp - Solenoid (Quick Coupler) 328-2035 28 H-5

Note: Check Part Number In The Part Manual For Your Specific Machine.
TAP TABLE

Tap Locations
Pressure, Sampling, and Sensor
Tap Schematic
Description
Number Location
AA Idler Pump Delivery Pressure C-5
BB Drive Pump Delivery Pressure A-5
CC Power Shift Pressure 1 A-3
DD Pump Drain Pressure B-5
EE Power Shift Pressure 2 C-3
PG Pilot Pump Delivery Pressure A-6
SOS Oil Sampling Port A-6
14 13 12 11 10 9 8 7 6 5 4 3 2 1
(20) VALVE GP
TP PILOT (TRAVEL)
310-0414 BUCKET CYLINDER STICK CYLINDER BOOM CYLINDER
TT

5 6 3 2 PD-Dr TRAVEL(L) TRAVEL(R)


J J
1
4
(Dimensions: 48 inches x 35 inches)

4 1
(18) VALVE GP 5 6 3 2 PD-Pi
PILOT (JOYSTICK) (LH)
297-0533
UENR5863

JLP JRP (FWD) (BKWD) (BKWD) (FWD)


T2 T5 T1 T3 T6 T4 AR3 BR3 AL3 BL3 AR4 BR4
JLT JRT
STICK SWING BUCKET BOOM
bL1 aL1 aR1 bR1
I I

(L)
(19) VALVE GP
(OUT) (IN) (R) (OPEN) (CLOSE) (DOWN) (UP)
PILOT (JOYSTICK) (RH)
JL1 JL3 JL2 JL4 JR2 JR4 JR1 JR3
297-0532
UNLOCK LOCK
36 Page,

(28) VALVE GP
SOLENOID (QUICK COUPLER)
255-5683
C1 C2

H H
A1 A2 A3 A4 A5 A6 A7 A8 (23) VALVE GP
SHUTTLE (CAB)
185-0462 P T

(14) VALVE GP QC-P QC-T


LOAD CONTROL (15) VALVE GP
B1 B2 B3 B4 B5 B6 B7 B8 SDr SPi (BOOM DRIFT RED, LINE RELIEF) LOAD CONTROL
255-5680 (STICK DRIFT RED, LINE RELIEF)
aR3 bR3 bL2 aL2 SPi BR5 BL3 AL3 BDr BPi 255-5683

aL4 AL4 BR4 BR5 AR5


G aL4 Pi1 bR5 Pi2 G
SP3 SP2 BP3 BP2
aL4-2 AR5 aL2
BPi bL3 bL4 aL3 PRV-P1

bR4 aR4 AL4 aL3 aL2-2 BL1 Di4 Pi4 BR1 AR1 AR4
(6) MOTOR GP aR5
QC-P
SWING AL2 AL1 aR3 Pi1
334-9968
(16) VALVE GP C/V-T R3
SWG SWING MOTOR BL2 aL1 aR1 BR3 AR3 aR4
MAIN CONTROL
PRKG BK
(STANDARD) T SP1 ST aR2 BR2 AR2 BP1 BT
CONTROL PG
259-7464 (UP) BL3 R2 (IN) (L) (BACK) (BACK) (CLOSE) (DOWN) BR4 R1 (IN)
(17) VALVE GP
SWG DR
F MOTOR MAIN CONTROL F
DRAIN (HEAVY LIFT)
MU 285-1323

MU
AG BG

A1 DR B1

(25) VALVE GP
SWING CUSHION
BOOM(2)

ATCH

BUCKET
SWING

TRAVEL(R)

BOOM(1)

STICK(2)
E (FINE SWING) E

TRAVEL(L)
STICK(1)
322-8716

(OUT) (R) (FWD) (FWD) bR2 (OPEN) (UP) (OUT)

DST
Di3 bL2-2 bR1
bR3 bR4 Di1 bR5 HR
PR
(R) A B (L) HL bL4 Di2 Pi2 bL3 Pi3 bL2 bL1
PL
BL2 AL2 RR FR
aL2-2 bL2-2 (24) VALVE GP
D (7) MOTOR GP (8) MOTOR GP Pi5 D
(22) VALVE GP U Pi5 SOLENOID (HEAVY LIFT)
TRAVEL (LH) TRAVEL (RH)
SHUTTLE HEAVY LIFT 352-7176
209-5992 209-5992
TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT) 164-6979
aL4-2
T P
aR5 Pi3 HL - Dr HL - Pi
(5) MANIFOLD GP (9) PUMP GP
2 SPEED MAIN HYDRAULIC
TRAVEL CONTROL
HL - Pi (PILOT OIL SUPPLY)
HEAVY LIFT 376-8862
CONTROL (21) VALVE GP
230-2720 B1 A1 B2 A2
PRESSURE REDUCING G2
(BOOM, SWING PRIORITY) (11) SENSOR AS Pn2
C Pi4 MF-P Di4 PD-Pi PD-Dr Di3 PRESSURE M2 HL C
310-0210
Pp3 Pp3 (IDLER PUMP) Ps2
P2 Pi1 P-IN PSA2 DR1 PSA1 T-OUT2 DR2 AA EE
366-9312
Dr A2
PRV-Dr PsM2
T1 T1 PL
P1 P2
T2 T2 DST G4
PRV-P1 PRV-P2 LINE PATTERNS
(4) FILTER GP
Pressure Line
PRV-P2 OIL (HYDRAULIC, CASE DRAIN) S1 Pm Pilot / Load Sensing Pressure
(1) ACCUMULATOR GP 289-8194 Drain / Return Lines

AG BG BG AG
P1
HYDRAULIC (CHARGED)
169-6981 QC-T
S3
M Component Group

CALLOUTS

B PAC SDr G3 YY Taps (Pressure, Sampling, Sensor - by letter) B


Dr
DR3 DR4 Pi2 DR5 T-OUT1 DR6 DD DrM PsM1
DL DL D Connectors (By letter)

BDr Callout Number


(52) VALVE GP - CONTROL
Component

HL - Dr DRAIN (Machine Location from


Component LocationsTable)
138-1234
Name

SWG MF-TANK FILTER


Part Number

A3
A B B A
PRV-Dr PRKG BK Di1 MF-P PR Ps1 CC HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
CONTROL A1
HR
PILOT PUMP OUTPUT
DRIVE PUMP OUTPUT
Di2 OUT IN BB Pn1 LEFT TRAVEL CONTROL AND LEFT TRAVEL MOTOR CIRCUIT
SUPPLY LINE
Ps M1 STICK CONTROL AND STICK CYLINDER CIRCUIT
(26) VALVE GP (27) VALVE GP PS PRESS EPRV
ATTACHMENT CIRCUIT
(13) VALVE GP G1 SWING CONTROL AND SWING MOTOR CIRCUIT
TRAVEL COUNTERBALANCE TRAVEL COUNTERBALANCE R3 MF-TANK T DRAIN / RETURN LINE
(BKWD) (FWD) (BKWD) (FWD) CHECK Pi
SWING BREAK CONTROL CIRCUIT
(LH) (RH) IDLER PUMP OUTPUT

AL1 BL1 AR1 BR1 369-8420 (10) SENSOR AS TRAVEL SPEED CONTROL CIRCUIT
322-8714 322-8714 B D
BUCKET CONTROL AND BUCKET CYLINDER CIRCUIT

2 SPEED PRESSURE Ps
RIGHT TRAVEL CONTROL AND LEFT TRAVEL MOTOR CIRCUIT
BOOM CONTROL AND BOOM CYLINDER CIRCUIT

A TRAVEL A G PG PC (DRIVE PUMP) POWER SHIFT CONTROL CIRCUIT


A
C/V-T
HEAVY LIFT CONTROL CIRCUIT
CONTROL 366-9312
SWG PG SOS THIS SCHEMATIC IS FOR THE 320D2 AND 323D2 EXCAVATOR HYDRAULIC SYSTEM
DRAIN (12) SWIVEL GP E F (3) FILTER GP (2) FILTER & VALVE GP ATTACHMENT: QUICK COUPLER
MOTOR C
FILTER 234-4440 OIL (HYDRAULIC RETURN) PILOT (HYDRAULIC OIL)
MEDIA NUMBER: UENR5863-01
DRAIN
188-4140 SCHEMATIC PART NUMBER: 369-8412, CHANGE: 00, VERSION: HE
158-8987 Components are shown installed on a fully operable machine with the key and engine off, with parking brake set.
MU Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

14 13 12 11 10 9 8 7 6 5 4 3 2 1
MAIN PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

28

PG
DD

CC

BB
AA
SOS
10

AA

11

EE
MAIN CONTROL VALVE - FRONT VIEW
VIEW ALL CALLOUTS

16

17

14

21

24
15

1
5

22
NOT
SHOWN
MACHINE - TOP VIEW
VIEW ALL CALLOUTS
13 6 25 12

3
MACHINE - RIGHT REAR VIEW
VIEW ALL CALLOUTS

7
26

27 8
CAB - TOP VIEW