LFC 5000

Versatile and dependable fluid inventory


control and management system

The ability to start a dispense from a


keypad or shop PC.

Hose reels are locked out by solenoids. Each


dispense request opens up a solenoid valve,
activating a green ready light, indicating the
dispense is ready to proceed.

All transactions can be viewed


from the master PC software
at a parts counter or service desk.

• System saves money and time by • Technicians can initiate a dispense from
accurately tracking and accounting any keypad, shop PC or master PC
for dispensed fluids • Designed for durability since the brains
• System provides 100% interface reliability of the LFC 5000 can be located on the
with management software programs wall of the service bay, away from the
such as ADP and AssetWorks day-today service bay hazards. Wireless
• Multiple users can dispense simultane- systems, in comparison, have the most
ously on the same system expensive and delicate part of the system
• Simple, packaged design provides the located in the hand-held dispensing
ability to easily and cost effectively expand meter which is in constant use and abuse
the system as your company grows • Barcode scanners can be used from a
• Three levels of security let you decide keypad or PC to offer better efficiency and
who can use, program and monitor the features during a dispense initiation
system
• System manages up to 32 fluids and 300
dispense locations
• Ability to integrate both standard and high
flow meters with one system
Providing complete lubrication solutions
Diaphragm pumps Thermal relief kits Ready light
Diaphragm pumps are ideal for Model 282876 Model 500072
transferring used fluids from Thermal relief valves prevent system A ready light is used so the
collection equipment to bulk storage damage by temperature induced mechanic knows the hose reel
locations. Pump sizes from 1/4 to 1 in. pressure spikes. Various models with is ready to dispense.
(6,35 to 25,4 mm) can quickly different pressure ratings are available.
transfer used oil, transmission
fluid, coolant,
windshield
washer solvent
and other
light fluids.

PowerMaster III
Model 2014
Heavy duty 12:1 pump
for delivering engine,
transmission lubricants,
etc. over long distances.
Model 282886 master air solenoid
Suitable for simultane-
An optional safety feature that activates
ous dispensing.*
air to the pumps only when the system
is dispensing.
Connects to one
of the inputs on
a dispense unit.

Tank monitoring
The LFC 5000 uses a self-declining
tank level in the standard software
package or you can
add an automatic
tank monitor system
which will adjust the
tanks in real-time.

Used fluid drains


Lincoln offers portable used fluid
equipment in a wide range of
configurations, capacities, materials
and colors. Drains and
evacuators are available
for collecting used fluids
under lift-mounted
vehicles or by dipstick
tube extraction.

PowerMaster III Low level cutoff


Model 2010 Model 82439
Heavy duty 50:1 A low lever cutoff is recommended for
chassis grease pump all pumps using a fluid control system
for 400 lb. (181 kg) to prevent air from
drum. getting into the
fluid line.
* Maximum pumping distances and flow rates for single
and simultaneous dispenses should be calculated using
Lincoln’s Vehicle Service Planning Manual. Contact your
local Lincoln sales manager for details.

2
for vehicle service facilities
Model 500020-A combo unit Heavy-duty hose reels LFC 5000 dispense unit
A solenoid is used to lock out the flow of fluid Model 94300 Model 500000-A
and a pulse meter is used to count the fluid Various sized single and dual One per every six reels which controls
dispensed. There are several sizes of each for arm reels are available in turning off and on the solenoids and
different flow rate capabilities different hose accepts the input from the pulse me-
or you can use the standard sizes and ters. Connects to standard AC power
flow combo unit which has pressure and has a 4 port
an integrated pulse meter, ratings. Ethernet switch to
solenoid, and contamination connect to a LAN
filter in one unit. network.

Decorative
overhead
cabinets

LFC 5000 keypad


Model 500001
Used to set up system,
initiate dispenses and
print reports from out
in the service bays.
Optional external bar
code scanner is
available.

LFC 5000 virtual keypad


Software installed
on PC’s in the
service bays that
Control valves Control valves allow mechanics
Lincoln has a complete line of standard Model 740 to initiate a
and high flow control valves and dispense.
meters. These or any existing units
can be used.

LFC 5000 software screen


Software that can be installed at the
parts counter, managers desk, or server
that monitors and operates the system.
The software has the option to initiate
dispenses, generate reports, view
transactions, and make adjustments
PMV pumps Series 20, 25 and 40 pumps to the configuration as needed.
Model V450400000 Medium duty 3:1 and 5:1
Medium duty 50:1 chassis grease pump pumps for delivering engine,
for 400 lb. (181 kg) drum. transmission lubricants, etc.
over moderate distances.
Model V406000000, a medium duty 6:1 pump, Best for single or limited
is also available for delivering engine, transmis- volume simultaneous
sion lubricants, etc, over moderate distances. dispensing.*
Suitable for simultaneous dispensing.*

3
LFC 5000 overview
The LFC 5000 is a versatile system that can Service bay
adapt to any location. The LFC 5000 wired computers
system is based on an ethernet network
that allows for easy, fast and 100% reliable
communication which is key when the
control system is interfaced with a dealer
management system. The network connec-
tions are easy; simply plug each keypad and
dispense unit into each other with the Cat 5
ethernet cable.
Every LFC 5000 system is hard wired
from the dispense point to the dispense unit.
This method is the most reliable and secure
form of communication to virtually ensure
the least amount of down time which
deducts from your site’s bottom line.
If a wired network is not possible, wireless
capabilities exist from the dispense unit to
the PC. Lincoln utilizes the 802.11 WiFi
protocol which is a fast and mature protocol
that easily integrates into a site’s existing
wireless network. You can also have a
mixture of wired and wireless dispense
units in the system. Master PC in an office, parts
For a stand-alone system, the dispense counter, or server room
units and keypads can be wired on their own Red wire
CAT 5 ethernet wire for the keypad, dispense unit and Master PC
network; separate from the sites existing Black wire
network. This offers an easy deployment Solenoid and pulse meter wire to the dispense unit
and avoids any security concerns.
For a more advanced setup to adapt to
your sites existing network, each of the dis- LFC 5000 dispensing unit
pense units and keypads can be connected
over your existing network. Each dispense
unit and keypad have a unique MAC address Connections for
and IP address which allows the units to wiring the solenoids
and pulse meters
route information over an existing network
to the PC running the system. This method 4 port ethernet
can save on wiring costs and helps a site switch for connect-
ing into the network
maintain complete control of their to the PC and
components. keypads

Keylock switch to activate the solenoids in


case of emergency

C AUTIO N
For all systems described in this bro-
chure, see important product usage
information on the back cover.

4
Software capabilities
Master PC software
• Used to configure the system, print and
export reports, initiate dispenses, view
tank levels, view the completed dispenses,
close open dispenses, and update the
firmware of Lincoln components
• Installed on one PC
• Connected to Lincoln network of dispense
units (DUs) and keypads
• Enable 5 different optional fields or
headings such as work order numbers,
equipment numbers, and odometer
reading to be entered at the keypad or
PCs prior to a dispense
• 4 unique timeout settings: initial, pre-
dispense, post dispense and free dispense
• 3 different levels of authorization: con-
figurator, manager and service technician.
• 300 unique hoses that can be setup for Master PC software
either preselect or free dispense
• 3 different language options per user:
English, French and Spanish.
• Configure up to 32 tanks with 4 different
alarm set points with self-declining tank
Master PC software system configuration
level status
• Optional automatic tank monitor with real
time level update

Remote report software


• Allows any user to print reports from the
system if it is on the sites same internal
network as the master PC software

Virtual keypad software


• Initiate dispenses from shop PCs
• PC must be on the same internal network
as the Master PC
• Can be used with or without physical
keypads

Tank monitor software


• Real time level updates
• Can be used with the LFC 5000 system
or as a stand-alone system
• E-mail notification for tank set points
and alarms
• Reports on tank levels, product deliveries,
and a special 10 day variance report that
shows any variances between what the
LFC 5000 system dispensed and what the
Virtual keypad software
tank monitor system shows

5
Interface capabilities
Interfaces with fleet management LFC 5000 can easily interface with your Preload and group preload capabilities
systems and dealer management existing dealer management systems • Preload up to five different fields for the
systems with the following offering: • Site has ability to create their own inter- system to verify before a dispense is
• Validate up to five unique fields such as face with a configurable flat file output accepted.
work orders and job numbers that are which is standard in the software package • Preload fluid types and quantities to a
configurable in the system setup • Lincoln’s transaction-to-disk method work order or equipment number to
• Validate fluid type and fluid quantity for allows a site to easily adapt their business verify the mechanic’s dispense request
the equipment number solution software to validate and directly • Initiate one dispense request to multiple
• Direct billing to accounting and inventory bill using the LFC 5000 hoses with preset quantities from a single
systems with five different rounding and field such as an equipment number or
pricing methods work order
• Export more than 15 fields after each
transaction
• Interfaces are available for ADP,
AssetWorks, Procede Software and
many more

LFC 5000 technical data


System specifications Network and PC specifications

Dispense Points per DU 6 • Software works with Windows XP, Vista, 7, Server 2003,
Dispense Units per System 50 Server 2008 and Server 2012
Maximum Dispense Points 300 • Two network cards for default IP configuration if using a separate
network
Maximum Number of Fluids 32 • Pentium 4 or newer PC with 2 GB of RAM
Maximum Number of Keypads 50 • Requires administrative access to install and run the Master PC
Maximum Number of Virtual Keypads 30 software
• The system can be configured to use any available IP addresses on
Master Air Solenoid Output per System 1 the same IP block
Printer 1 parallel port is on each
keypad that will use any
standard printer with a Default static IP addresses
parallel port connection Dispense unit 1 through 50 10.10.10.1-50

Keypad 1 through 50 10.10.10.101-150

PC 10.10.10.101
Electrical specifications
Tank monitoring 10.10.10.251

Keypad Power Input 90 to 240 V AC, 50/60 Hz


Dispense Unit Power Input 100 to 240 V AC, 50/60 Hz
Ready Light 0.1 Amp @ 24 V DC

Combo Unit 0.8 Amp @ 24 V DC


Master Air Solenoid 0.1 Amp @ 24 V DC

6
Wiring Report capability

500006-A 1 ft. (0,3 m) combo unit pigtail Transaction ticket Prints a transaction per page to the default
276068-10 10 ft. (3 m) combo unit to dispense unit cable assembly printer on the master PC and/or one or two
276068-25 25 ft. (7,6 m) combo unit to dispense unit cable different printers connected to keypads
assembly 276068-25
All user reports List of user names with their corresponding
276068-50 50 ft. (15,2 m) combo unit to dispense unit cable pin numbers and levels of access
assembly 276068-25
276068-75 75 ft. (22,9 m) combo unit to dispense unit cable System configuration Record of system set-up for reconfiguration
assembly 276068-25 report and service
276068-100 100 ft. (30,5 m) combo unit to dispense unit cable
assembly 276068-25 Tank status report Record of current levels, capacities and
alarm alerts
276068-150 150 ft. (45,7 m) combo unit to dispense unit cable
assembly 276068-25 Transaction report Record of product usage and total with filters
500041 Dispense unit 12 ft. (3,7 m) power cable shown below
500042 Dispense unit 20 ft. (6 m) power cable
Transaction report Print-friendly report designed to minimize
Master air Any of the combo-unit-to-dispense-unit assemblies condensed paper
solenoid wire listed above
Filters Date range
Transaction state - completed but not closed,
failed with error, pending dispense,
completed and closed, canceled by user
Hose
Tank
User
Sort by any input
Network wire (Cat 5 or Cat 6) not supplied by Lincoln

Dispense timeouts Tank levels and alarms

Initial timeout 0 to 1 200 seconds Tank capacity 1 to 99999 units


Predispense timeout 0 to 1 200 seconds Delivery-level warning 0 to 99999
Postdispense timeout 0 to 1 200 seconds Low-level warning 0 to 99999

High-level warning 0 to 99999


Stop-level warning 0 to 99999
Type New/used

Operator capacities Character lengths

Number of users 200 User name 16


Simultaneous dispenses 300 User code 16
Transaction logs Unlimited Optional fields 1 through 5 16
Tank descriptions 16

7
The Power of Knowledge Engineering These competence areas include bearings and
Combining products, people, and application- units, seals, lubrication systems, mechatronics,
Bearings and Lubrication
Seals
housings systems
specific knowledge, SKF delivers innovative and a wide range of services, from 3-D computer
solutions to equipment manufacturers and pro- modelling to cloud-based condition monitoring
duction facilities in every major industry world- and asset management services.
wide. Having expertise in multiple competence SKF’s global footprint provides SKF customers
Mechatronics Services
areas supports SKF Life Cycle Management, a with uniform quality standards and worldwide
proven approach to improving equipment reliabil- product availability. Our local presence provides
ity, optimizing operational and energy efficiency direct access to the experience, knowledge and
and reducing total cost of ownership. ingenuity of SKF people.

Important information on product usage


! All products from Lincoln may be used only for their intended purpose as described in this
brochure and in any instructions. If operating instructions are supplied with the products, they
must be read and followed.
Not all lubricants are suitable for use in centralized lubrication systems. Lincoln does offer an
inspection service to test customer supplied lubricant to determine if it can be used in a central-
ized system. Lincoln lubrication systems or their components are not approved for use with
gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding
normal atmospheric pressure (1 013 mbar) by more than 0,5 bar at their maximum permissible
temperature.
Hazardous materials of any kind, especially the materials classified as hazardous by European
Community Directive EC 67/548/EEC, Article 2, Par. 2, may not be used to fill SKF centralized
lubrication systems and components and delivered and/or distributed with the same.

Please contact: This brochure was presented by:


SKF USA, Inc.
One Lincoln Way
St. Louis, MO 63120 USA
Tel. +1 (314) 679-4200

® SKF is a registered trademark of the SKF Group.


® Lincoln is a registered trademark of Lincoln Industrial Corp.
Windows XP, Windows Vista and Windows 7 are either registered trademarks or trademarks of Microsoft Corporation in the United
States and/or other countries.
© SKF Group 2014
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-
sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
SKF PUB LS/P2 14471 EN.US · February 2014 · FORM 444024

lincolnindustrial.com skf.com

You might also like