Option
For Emotron TSA softstarter
Instruction manual
English
Emotron Isolated USB and RS485
Option
For Emotron TSA softstarter
Instruction manual - English
Safety
The following indications can appear in this manual. Always read these first and
be aware of their content before continuing:
CAUTION!
Failure to follow these instructions can result in malfunction
! or damage to the softstarter.
WARNING!
Failure to follow these instructions can result in serious injury
to the user in addition to serious damage to the softstarter.
Installation
Installation, commissioning, dismounting, making measurements, etc. on the
main product may only be carried out by personnel who are technically quali-
fied for the task. Installation must also be carried out in accordance with the
local standards. Ensure that all necessary safety measures are taken.
WARNING!
Take all necessary safety precautions during installation and
commissioning to prevent personal injuries, e.g. by an
uncontrolled load.
WARNING!
Always switch off the mains supply and control supply before
opening the main product.
Always take adequate precautions before opening the main product, even
though the connections for the control signals and jumpers are isolated from the
mains voltage.
Content ................................................................................. 3
1. General Information................................................................ 5
1.1 Introduction................................................................................................. 5
1.2 Users............................................................................................................ 5
1.3 Delivery and unpacking.............................................................................. 5
2. Connections .......................................................................... 7
2.1 Connections & Front view of isolated RS485 option ............................... 7
2.2 Connections and Front view of isolated USB option ................................ 8
5. Installation............................................................................ 21
5.1 Mechanical mounting.............................................................................. 21
5.2 Shielding................................................................................................... 23
1.1 Introduction
The isolated USB and isolated RS485 option are both a asynchronous serial
communication interface for the Emotron TSA soft starter series.
The protocol used for data exchange is Modbus RTU, originally developed by
Modicon. Physical connection is selected by option, either USB or RS485.
The product acts as a slave with address 1 to 247 in a master-slave configura-
tion. The communication is half-duplex. It has a standard non return to zero
(NRZ) format. Please refer to the instruction manual for the main product for
the maximum selectable baud rate.
The character frame format (always 11 bits) consists of (fixed):
• one start bit
• eight data bits
• two stop bits
• no parity bit
1.2 Users
This instruction manual is intended for:
• installation engineers
• designers
• maintenance engineers
• service engineers
RS 485 interface
9 - pole female interface. Galvanically isolated.
Connector interface
Pin # Function
1 Termination power, +5V, isolated
4 Note! Must leave unconnected / NC to enable RS485 function
5 GND, isolated signal ground
8 RxD/ TxD (negative/ inverted “B”) bidirectional RS485 line
9 RxD/ TxD (positive “A”) bidirectional RS485 line
Housing Cable shield connection
USB interface
connector type B
3.2 Protocol
Note! To make the motor start, both 42902 and 42903 or 42904 must be
set at the same time. Setting both 42903 and 42904 at the same time
will cause Emotron TSA to stop.
Exc.
Name Description
code
01 Illegal function This unit doesn’t support the function code.
02 Illegal data address The data address is not within its boundaries.
03 Illegal data value The data value is not within its boundaries.
The unit is unable to perform the request at this
06 Busy
time. Try again later.
Bus master
RS485
10
Fig. 4 RS 485 multipoint network
It is important that the first and the last unit in the network are terminated, i.e.
unit with Adr. 1 and 3 in figure above. See chapter 4.2.2 page 19 for details.
RS485-A RS485-A
RS485-B RS485-B
Shield Shield
NOTE: Brake the lid in the plastic cover hood to let the interface of the
fieldbus module become accessible from the outside.
1. Gently slide the fieldbus module into place. Make sure that the module
slides on to the guides on the board and into the 50-pin Compact Flash con-
tact. Do NOT use any force!
Fig. 6