Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Data Sheet: AFS 4 2C 60-150V BK

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Data sheet

AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG


Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com

Product image

In some applications it is useful to protect the feed


through connection with a separate fuse. Fuse terminal
blocks are made up of one terminal block bottom section
with a fuse insertion carrier. The fuses vary from pivoting
fuse levers and pluggable fuse holders to screwable clo-
sures and flat plug-in fuses.

General ordering data

Version Fuse terminal, PUSH IN, 4 mm², 150 V, 6.3 A,


black
Order No. 2434380000
Type AFS 4 2C 60-150V BK
GTIN (EAN) 4050118445107
Qty. 50 pc(s).

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 1


Data sheet
AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Dimensions and weights

Depth 68 mm Depth (inches) 2.677 inch


Depth including DIN rail 69 mm Height 74 mm
Height (inches) 2.913 inch Width 6.1 mm
Width (inches) 0.24 inch Net weight 17.751 g

Temperatures

Storage temperature -25 °C...55 °C Continuous operating temp., min. -60 °C


Continuous operating temp., max. 130 °C

Material data

Material Wemid Colour black


UL 94 flammability rating V-0

Rating data IECEx/ATEX

Certificate No. (ATEX) TUEV17ATEX8064U Certificate No. (IECEX) IECEXTUR17.0030U


Current (ATEX) 6.3 A Wire cross section max. (ATEX) 4 mm²
Current (IECEX) 6.3 A Wire cross section max. (IECEX) 4 mm²
Marking EN 60079-7 Ex ec II C Gc Ex 2014/34/EU label II 3 G D

System specifications

End cover plate required Yes Number of potentials 1


Number of levels 1 Number of clamping points per level 2
Number of potentials per tier 1 PE connection No
Rail TS 35 N-function No
PE function No PEN function No

Additional technical data

Installation advice Rail Open sides right


Snap-on No Type of fixing Snap-on
Type of mounting TS 35 With snap-in pegs No

CSA rating data

Certificate No. (CSA) 200039-70089609 Current size B (CSA) 10 A


Current size C (CSA) 10 A Current size D (CSA) 10 A
Voltage size B (CSA) 300 V Voltage size C (CSA) 150 V
Voltage size D (CSA) 300 V Wire cross section max. (CSA) 10 AWG
Wire cross section min. (CSA) 26 AWG

Conductors for clamping (additional connection)

Connection type, additional connection PUSH IN

Conductors for clamping (rated connection)

Blade size 0.6 x 3.5 mm


Clamping range, max. 6 mm²
Clamping range, min. 0.14 mm²
Connection cross-section, stranded, 6 mm²
max.

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 2


Data sheet
AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A4
Number of connections 2
Stripping length 12 mm
Tube length for twin wire-end ferrule Tube length min. 8 mm
max. 12 mm
Cross-section for conductor connection min. 0.5 mm²
max. 1.5 mm²
Tube length for wire-end ferrule with Tube length min. 6 mm
plastic collar DIN 46228/4 max. 12 mm
Cross-section for conductor connection min. 0.5 mm²
max. 1 mm²
Tube length min. 8 mm
max. 12 mm
Cross-section for conductor connection min. 1.5 mm²
max. 2.5 mm²
Tube length min. 10 mm
max. 12 mm
Cross-section for conductor connection nominal 4 mm²
Tube length for wire-end ferrule without Tube length min. 6 mm
plastic collar DIN 46228/1 max. 10 mm
Cross-section for conductor connection min. 0.5 mm²
max. 1 mm²
Tube length min. 7 mm
max. 12 mm
Cross-section for conductor connection min. 1.5 mm²
max. 2.5 mm²
Tube length min. 9 mm
max. 15 mm
Cross-section for conductor connection min. 4 mm²
max. 6 mm²
Twin wire-end ferrules, max. 1.5 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection PUSH IN
Type of connection 2 PUSH IN
Wire connection cross section AWG, AWG 12
max.
Wire connection cross section AWG, AWG 26
min.
Wire connection cross section, finely 6 mm²
stranded, max.
Wire connection cross section, finely 0.5 mm²
stranded, min.
Wire connection cross-section, fine- 6 mm²
ly stranded with wire-end ferrules DIN
46228/1, max.
Wire connection cross-section, fine- 0.5 mm²
ly stranded with wire-end ferrules DIN
46228/1, min.
Wire connection cross-section, fine- 4 mm²
ly stranded with wire-end ferrules DIN
46228/4, max.
Wire connection cross-section, fine- 0.5 mm²
ly stranded with wire-end ferrules DIN
46228/4, min.
Wire connection cross-section, solid 4 mm²
core, max.

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 3


Data sheet
AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Wire connection cross-section, solid 0.5 mm²
core, min.

Fuse terminals

Cartridge fuse G-Si. 5 x 20 Display Red LED


Leakage current, max. 0.5 mA Operating voltage, max. 150 V
Power loss for overload and short-circuit Power loss for overload and short-circuit
protection for a composite arrangement 1.6 W at 6.3 A @ 34°C protection for an individual arrangement 1,6 W bei 6,3 A @ 31 °C
Power loss for short-circuit protection Power loss for short-circuit protection
only for a composite arrangement 2,5 W bei 6,3 A @ 32 °C only for an individual arrangement 4,0 W bei 6,3 A @ 41 °C

General

Installation advice Rail Rail TS 35


Standards Wire connection cross section AWG,
DIN EN 60947-7-3 max. AWG 12
Wire connection cross section AWG,
min. AWG 26

Rating data

Rated cross-section 4 mm² Rated voltage 150 V


Rated voltage to adjoining terminal 500 V Rated DC voltage 150 V
Rated current 6.3 A Current at maximum wires 6.3 A
Standards Volume resistance according to IEC
DIN EN 60947-7-3 60947-7-x 1 mΩ
Rated impulse withstand voltage Power loss in accordance with IEC
4 kV 60947-7-x 1.02 W
Pollution severity 3 Surge voltage category III

UL rating data

Certificate No. (cURus) Conductor size Factory wiring max. (cU-


E60693 Rus) 10 AWG
Conductor size Factory wiring min. (cU- Conductor size Field wiring max. (cURus)
Rus) 26 AWG 10 AWG
Conductor size Field wiring min. (cURus) 26 AWG Current size B (cURus) 10 A
Current size C (cURus) 10 A Current size D (cURus) 10 A
Voltage size B (cURus) 300 V Voltage size C (cURus) 150 V
Voltage size D (cURus) 300 V

Classifications

ETIM 6.0 EC000899 ETIM 7.0 EC000899


ETIM 8.0 EC000899 ETIM 9.0 EC000899
ECLASS 9.0 27-14-11-16 ECLASS 9.1 27-14-11-16
ECLASS 10.0 27-14-11-16 ECLASS 11.0 27-14-11-16
ECLASS 12.0 27-14-11-16 ECLASS 13.0 27-25-01-13

Environmental Product Compliance

REACH SVHC /
RoHS Compliance Status Compliant without exemption

Important note

Product information The voltage depends on the selected fuse element or the selected indicator light

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 4


Data sheet
AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Approvals

Approvals

ROHS Conform
UL File Number Search UL Website
Certificate No. (cURus) E60693
Certificate No. (cURusEX) E184763

Downloads

Approval/Certificate/Document of Con- Attestation of Conformity


formity IECEX_TUR_17.0030U.pdf
ATEX Certificate
DNVGL certificate
CCC Ex Certificate
CB Testreport
CB Certificate
20-AV4BO-0273U
CE Declaration of Conformity
UKCA declaration of conformity
Engineering Data CAD data -- STEP
Tender specification Klippon® Connect 2434380000 EN
Klippon® Connect 2434380000 DE
User Documentation NTI_ AFS 4 2C BK.pdf
StorageConditionsTerminalBlocks
User Manual AFS
Catalogues Catalogues in PDF-format

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 5


Data sheet
AFS 4 2C 60-150V BK Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Drawings

Creation date August 1, 2024 10:58:49 PM CEST

Catalogue status 13.07.2024 / We reserve the right to make technical changes. 6

You might also like