ZXA10 C6XX V1.1.0 Commissioning and General Operation Maintenance Guide V2.0
ZXA10 C6XX V1.1.0 Commissioning and General Operation Maintenance Guide V2.0
ZXA10 C6XX V1.1.0 Commissioning and General Operation Maintenance Guide V2.0
0
Commissioning and General
Operation Maintenance Guide V2.0
Confidential▲
LEGAL INFORMATION
By accepting this certain document of ZTE CORPORATION you agree to the following terms. If you do not
agree to the following terms, please notice that you are not allowed to use this document.
Copyright © 2019 ZTE CORPORATION. Any rights not expressly granted herein are reserved. This document
contains proprietary information of ZTE CORPORATION. Any reproduction, transfer, distribution, use or
disclosure of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.
The design of this product complies with requirements of environmental protection and personal security. This
product shall be stored, used or discarded in accordance with product manual, relevant contract or laws and
regulations in relevant country (countries).
This document is provided “as is” and “as available”. Information contained in this document is subject to
continuous update without further notice due to improvement and update of ZTE CORPORATION’s products
and technologies.
ZTE CORPORATION
Address: NO. 55
Hi-tech Road South
ShenZhen
P.R.China
518057
Website: http://dms.zte.com.cn (Technical Support)
Email: TSM.Aftersales@zte.com.cn
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 1
Confidential▲
Revision History
First published
Author
Prepared
Document Version Date Reviewed by Approved by
by
Lin
1.2 2019-1-23
Guoxin
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 2
Confidential▲
Follow-up document: After read this document, you may need the following information
SEQ Reference Material Information
1
2
3
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 3
Confidential▲
Contents
1 OVERVIEW ...................................................................................................................... 10
3.1 CONNECT VIA THE SERIAL PORT AND INTRODUCE PORTS ON THE
PANEL OF SWITCHING & CONTROL CARD .................................................... 16
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 4
Confidential▲
3.5.1 ADD THE IN-BAND MANAGEMENT VLAN TO THE UPLINK PORT ....... 23
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 5
Confidential▲
7.1.2 QUERY THE CONFIGURATION UNDER THE PON PORT (METHOD 1) .60
7.1.3 QUERY THE CONFIGURATION UNDER THE PON PORT (METHOD 2) .60
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 7
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 9
Confidential▲
1 Overview
The ZXA10 C6xxV1.1.0 version is not greatly different from ZXA10 C600V1.0.0 in
terms of equipment software commissioning and configuration, but just some new
functions are added. However, apart from C600 version, the ZXA10 C6xxV1.1.0 version
packages also integrate versions of such equipment as C620, C650, C680 and so on, and
add part of new maintenance diagnosis functions. To facilitate use of ZXA10 C6xxV1.1.0
version, and meet on-site commissioning and maintenance requirements, this document
is mainly to modify and supplement based on original ZXA10 C600V1.0.0 Version
Commissioning and General Operation Summary.
Following contents are comprised in this document:
1. Related data planning, including: uplink configuration planning,
GPON/XGPON/EPON/10GEPON service planning and data planning, etc.;
2. C600 global data configuration, including: serial port configuration, configuration of
multiple C6xx user name / password authentication modes, other global configuration
data needed by C6xx commissioning and so on;
3. GPON/XGPON/EPON/10GEPON service commissioning;
4. C6xx general maintenance operations.
At present, uplink ports of C600 is provided by uplink cards, while the switching &
control card SFUL doesn’t provide uplink ports; physical type supports optical port,
and it is 10G by default; configuration rate supports 1000M and 10G (decided by port
property). LACP aggregation is supported between ports, and same-card and span-card
LACP smartgroup are supported. Span-card aggregation is recommended. At present,
uplink ports can also configure UAPS protection groups, and support to configure UAPS
protection on the same card or span-card.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 10
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 11
Confidential▲
Start
Register ONU
If there is suitable
ONU profile?
N
Configure ONU
Configure TCONT
profile
Y
Save configuration
End
At present, EPON line card types supported by the C600 system include 10G EPON,
but not support pure 1G EPON line card. 10G EPON can support EPON channel and 10G
EPON channel (including symmetrical and asymmetric) at the same time, and the
maximum forwarding ability is upstream 10G, and downstream 10G.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 12
Confidential▲
The basic service configuration flowchart is shown as below. The flowchart is applicable
to all ONU types. For different ONU types, there may differ inside each step, for details,
refer to detailed description of each configuration step .
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 13
Confidential▲
Start
If there is suitable
ONU profile?
N
Configure ONU
profile
Add ONU
Configure bandwidth
Save configuration
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 14
End
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 15
Confidential▲
Plan service VLANs for each place according to your own requirements, for example:
ONU management:
SVLAN:3800 CVLAN :10 user-vlan:10
IPTV:
SVLAN: 3800 CVLAN: 51 user-vlan 51 multicast VLAN: 4070 ;
HSI:
SVLAN: 3750 CVLAN: 1000 user-vlan: 101 ;
VOIP:
SVLAN: 3850 CVLAN: 4001 user-vlan: 4001 ;
ONU rate-limit
TCONT rate-limit is used at upstream, while VPORT rate-limit or service-port rate-
limit is used at downstream. Configure TCONT bandwidth profile, service-port and vport
bandwidth profile (C600 doesn't support gemport rate-limit).
Authentication mode
EPON supports multiple authentication modes such as MAC\LOID\PW, configure
according to your own requirements on-site. Generally, LOID authentication is used.
Commissioning
Use a serial port cable to connect the CONSOLE port and PC of C600’s master main
control card, and set the serial port’s baud rate as 115200, and then you can log in the
OLT immediately after connected. The default enabling password is zxr10. The panel
figure of a C600 switching & control card is shown as below: USB port, CONSOLE port,
ODB port, MGMT out-band Ethernet port, DIAG interface from top to bottom. In addition,
at present, the DIAG interface can only be used for microcode debugging, inner / panel
port serdes debugging, control panel flow mirroring, but can’t be used for uplink port or
CPU mirroring and packet capturing. Therefore, at present, to mirror and capture packets
at the uplink ports, the optical-electrical module can only be used to connect a PC to
capture packets.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 16
Confidential▲
C600V1.0.0 version system has the default telnet user name zte, and password zte,
but starting from C6xxV1.1.0 version, the default user name / password can only be used
once, with the user name as zte, and password as ZxPon1!2@3#. Because the default user
name password will invalid after exited, you need to modify or create the user name /
password once again, otherwise, you will fail to log in again. However, in some places,
factory setting may set the default user name / password as zte, so when logging in for
the first time, try both passwords, or you can create a new user name, password
according to your own requirements. And set RADIUS or Tacacs authentication modes.
ZXAN#con t
ZXAN(config)#system-user
ZXAN(config-system-user)#user-name debug---------Set the user name according to your own
requirements
ZXAN(config-system-user-username)# password admin ----------Set the password according to your
own requirements
ZXAN(config-system-user-username)#bind authentication-template 1
ZXAN(config-system-user-username)#bind authorization-template 1
ZXAN(config-system-user-username)#exit
ZXAN(config-system-user)#authentication-template 1
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 17
Confidential▲
For users authenticated via RADIUS, configurations of C600 and C300 differ a lot:
ZXAN#con t
ZXAN(config)#system-user
ZXAN(config-system-user)#user-name debug---------Set the user name according to your own
requirements
ZXAN(config-system-user-username)# password admin ----------Set the password according to your
own requirements
ZXAN(config-system-user-username)#bind authentication-template 1
ZXAN(config-system-user-username)#bind authorization-template 1
ZXAN(config-system-user-username)#exit
ZXAN(config-system-user-default)#exit
ZXAN(config-system-user)#exit
ZXAN(config-system-user-username)#exit
C6xx equipment doesn’t need to add racks and shelves, which is automatically
identified by the system. At the same time, the PNP function is enabled by default:
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 20
Confidential▲
ZXAN(config)#show pnp
Equipment PNP function is enable.
To disable the PNP function:
ZXAN(config)#set-pnp disable -------------------Enabling the PNP function needs to configure it as
enable
ZXAN(config)#show pnp
Equipment PNP function is disable.
At the same time, C600 and C300 are the same, no matter whether to enable the PNP
function or not, switching & control cards are automatically identified to generate, with
no need to manually add. During commissioning, if PNP is disabled, you only need to
manually add uplink cards and service cards.
Manually add cards by using following commands:
ZXAN#config t
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 1 GFBH
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 2 GFXH
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 3 GFGO
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 4 GFGH
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 5 GFXO
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 6 EFTO
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 7 EFTH
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 18 XFTO
ZXAN(config)#add-card rackno 1 shelfno 1 slotno 19 XFTO
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 21
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 22
Confidential▲
Add the planned in-band management VLAN, service VLAN into the uplink port:
ZXAN#con t
ZXAN(config)#interface xgei-1/18/1
ZXAN(config-if-xgei-1/18/1)#switchport mode hybrid
ZXAN(config-if-xgei-1/18/1)#switchport vlan 66 tag
ZXAN(config-if-xgei-1/18/1)#switchport vlan 100-200 tag
ZXAN(config-if-xgei-1/18/1)#exit
ZXAN(config)#interface xgei-1/19/1
ZXAN(config-if-xgei-1/19/1)#switchport mode hybrid
ZXAN(config-if-xgei-1/19/1)#switchport vlan 66 tag
ZXAN(config-if-xgei-1/18/1)#switchport vlan 100-200 tag
ZXAN(config-if-xgei-1/19/1)#exit
ZXAN(config)#interface smartgroup1
ZXAN(config-if-smartgroup1)#switchport mode hybrid
ZXAN(config-if-smartgroup1)#switchport vlan 66 tag
ZXAN(config-if-xgei-1/18/1)#switchport vlan 100-200 tag
ZXAN(config-if-smartgroup1)#exit
ZXAN(config)#lacp
ZXAN(config-lacp)#interface smartgroup1
ZXAN(config-lacp-sg-if-smartgroup1)#lacp mode 802.3ad -------Configure smartgroup dynamic
mode
ZXAN(config-lacp-sg-if-smartgroup1)#lacp load-balance src-mac --Configure the load balance
mode
ZXAN(config-lacp-sg-if-smartgroup1)#exit
ZXAN(config-lacp)#interface xgei-1/18/1
ZXAN(config-lacp-member-if-xgei-1/18/1)#smartgroup 1 mode active
ZXAN(config-lacp-member-if-xgei-1/18/1)#exit
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 23
Confidential▲
ZXAN(config-lacp)#interface xgei-1/19/1
ZXAN(config-lacp-member-if-xgei-1/19/1)#smartgroup 1 mode active
ZXAN(config-lacp-member-if-xgei-1/19/1)#exit
ZXAN(config-lacp)#exit
ZXAN(config)#interface xgei-1/18/1
ZXAN(config-if-xgei-1/18/1)#no shutdown -------------------------- The uplink port and PON port are
shutdown by default, first, you need to configure no shutdown to be able to use
ZXAN(config-if-xgei-1/18/1)#exit
ZXAN(config)#interface xgei-1/19/1
ZXAN(config-if-xgei-1/19/1)#no shutdown -------------------------- The uplink port and PON port are
shutdown by default, first, you need to configure no shutdown to be able to use.
ZXAN(config-if-xgei-1/19/1)#exit
If LACP of both ends has already been configured, and interconnected successfully,
show LACP status as following:
ZXAN#show lacp 1 counters
Smartgroup:1
Actor LACPDUs Marker LACPDUs Marker
Port Tx Rx Tx Rx Err Err
-------------------------------------------------------------------
xgei-1/18/1 2605 2548 0 0 0 0
xgei-1/19/1 2605 2556 0 0 0 0
ZXAN#show lacp 1 internal
Smartgroup:1
Flags: * - Port is Active member Port
S - Port is requested in Slow LACPDUs
F - Port is requested in Fast LACPDUs
A - Port is in Active mode
P - Port is in Passive mode
Actor Agg LACPDUs Port Oper Port RX Mux
Port[Flags] State Interval Pri Key State Machine Machine
--------------------------------------------------------------------------------
xgei-1/18/1[SA*] ACTIVE 30 32768 0x121 0x3d CURRENT COLL&DIST
xgei-1/19/1[SA*] ACTIVE 30 32768 0x121 0x3d CURRENT COLL&DIST
ZXAN#show lacp 1 neighbors
Smartgroup 1 neighbors
Actor Actor Partner Partner Port Oper Port
Port Port No. System ID Port No. Priority Key State
-------------------------------------------------------------------------------
xgei-1/18/1 4609 0x8000,cc1a.faea.0ee0 8276 32768 0x1f21 0x3d
xgei-1/19/1 4865 0x8000,cc1a.faea.0ee0 8290 32768 0x1f21 0x3d
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 24
Confidential▲
Protect-time : 300s
Is-in-protect-time : no
Next-hop : 0.0.0.0
Link-detect-retry : 5
Link-detect-interval : 3s
Failure-time : 430s
Swap-reason : no swap
xgei-1/18/1: down
xgei-1/19/1: down
ZXAN(config)#uaps-group
Precautions:
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 25
Confidential▲
1) Data configuration of the master active port and slave active port participating in
protection switching must be consistent, the UAPS function itself doesn’t have the
automatic synchronize data function.
2) Service forwarding of the master active port and slave active port participating in
protection switching doesn’t exist load balance relationship, but just simple master /
slave protection relationship.
Precautions:
1. The switching protection time is the interval from triggering switching back to the
master port after the master active port recovers to normal.
2. To make the switching protection time take effect, the automatic revertive function
needs to be enabled.
Precautions:
2)For multi-port UAPS protection groups, the switching trigger condition can be set as
max-port mode, meaning that as long as faulty ports among current active ports are
more than non-active ports, switching will be triggered.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 26
Confidential▲
Precautions:
Smartgroup port must be manually added into the UAPS group, and you can’t
directly add smartgroup through commands. The switching trigger mode must be set as
trunking.
ZXAN(config-uaps-1)#exit
After the adding of the UAPS port is completed, configure two smartgroup
protection groups. The configuring order of smartgroup or uaps protection groups
doesn’t matter, it is OK about which one is configured first. For smartgroup
configuring method, please refer to above Section 5.
Protect-time : 300s
Is-in-protect-time : no
Next-hop : 0.0.0.0
Link-detect-retry : 5
Link-detect-interval : 3s
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 27
Confidential▲
Failure-time : 136s
xgei-1/18/6: down
xgei-1/19/6: down
xgei-1/18/7: down
xgei-1/19/7: down
Smartgroup:1
--------------------------------------------------------------------------------
Smartgroup:2
--------------------------------------------------------------------------------
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 28
Confidential▲
ZXAN(config-lacp)#
At present, the EMS version supporting C600 NE management is T125 and later
versions. After the NE is added on EMS, configure the community name and view, which
are strict case-sensitive. In addition, all snmp versions are Disable in the system by
default, corresponding snmp version needs to configured as Enable on the NE. Following
are examples to configure snmp v2c enable and configure the trap server.
ZXAN#config t
Enter configuration commands, one per line. End with CTRL/Z.
ZXAN(config)#snmp-server version v2c enable --------Enable the SNMP V2C
ZXAN(config)#snmp-server community public view Allview rw --------Configure the community name,
view must be AllView, and pay attention to case
ZXAN(config)#snmp-server enable trap ------------------Enable the snmp trap
ZXAN(config)#snmp-server host 198.10.10.10 trap version 2c public --------Configure the trap server
View the configuration effect:
ZXAN(config)#show snmp config
snmp-server community encrypted
d6ddeaa4dab74523b246fe346c94c31ae58b79ad4776396438ea1e9bb01a9ef3 view AllView rw
snmp-server engine-id is 830900020300010289d64401
snmp-server host 198.10.10.10 trap version 2c encrypted
d6ddeaa4dab74523b246fe346c94c31ae58b79ad4776396438ea1e9bb01a9ef3 udp-port 162 snmp bgp
mac ospf stp ppp arp rmon
udld cfm efm lacp mc-elam tcp sctp stalarm cps interface acl fib pim isis rip msdp aps config am um
system ldp pwe3 vpn mpls-oam ptp tunnel-te radius dhcp bfd ippool n
tp ssm sqa ipsec cgn vrrp ftp_tftp ping-trace gm
snmp-server packetsize is 8192
snmp-server view AllView internet included
snmp-server view DefaultView system included
snmp-server security dynamic-trust-user idle-timeout 1800
snmp-server listen-port is 161
snmp-server version v2c enable
snmp-server input-limit 200
Note: If there are no special requirements, do not enable inform at will: ZXAN(config)#snmp-
server enable inform
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 29
Confidential▲
Otherwise, it may cause EMS or third-party EMS to receive too many messages, leading to
congestion.
If misoperations appear, please configure as below:
ZXAN(config)#no snmp-server enable inform
The default master / slave working mode of the C600 system is Proxy. As for whether to use snooping or
proxy, configure according to needs of users.
ZXAN#config t
Enter configuration commands, one per line. End with CTRL/Z.
ZXAN(config)#igmp enable ---------------Generally, it is enable by default
ZXAN(config)#igmp span-vlan enable
ZXAN(config)#igmp mvlan 4070
ZXAN(config-igmp-mvlan-4070)#work-mode proxy
ZXAN(config-igmp-mvlan-4070)#group 235.254.196.1 to 235.254.196.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.197.1 to 235.254.197.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.198.1 to 235.254.198.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.199.1 to 235.254.199.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.200.1 to 235.254.200.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.201.1 to 235.254.201.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.202.1 to 235.254.202.255
ZXAN(config-igmp-mvlan-4070)#group 235.254.203.1 to 235.254.203.255
ZXAN(config-igmp-mvlan-4070)#prejoin-group 235.254.196.1
ZXAN(config-igmp-mvlan-4070)#prejoin-group 235.254.198.51
ZXAN(config-igmp-mvlan-4070)#source-port xgei-1/19/1
ZXAN(config-igmp-mvlan-4070)#source-port smartgroup1----------------If uplink is smartgroup, you
need to add smartgroup as the source port
ZXAN(config-igmp-mvlan-4070)#receive-port vport-1/1/1.3:2 -------------Add the receive port according
to needs of the user, which can be configured after the ONU is added.
ZXAN(config-igmp-mvlan-4070)#receive-port vport-1/1/1.1:2
ZXAN(config-igmp-mvlan-4070)#receive-port vport-1/1/1.4:2
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 30
Confidential▲
ZXAN(config-igmp-mvlan-4070)#receive-port vport-1/1/1.5:2
ZXAN(config-igmp-mvlan-4070)#receive-port vport-1/1/1.6:2
ZXAN(config-igmp-mvlan-4070)# exit
ZXAN(config)#vlan 3801
ZXAN(config-sub-3801)#igmp span-vlan ------------VLAN 3801 is the SVLAN for multicast to get the
DHCP IP address. This configuration is very important, otherwise, upstream won’t retrieve packets but
transparently transmit under the circumstances of span-VLAN multicast.
ZXAN(config-sub-3801)#exit
ZXAN(config)#vlan 4070
ZXAN(config-sub-4070)#multicast-packet dropUnknown -------------Configure to drop multicast flood
messages
Note: The system adopts span-VLAN multicast by default, multicast VLAN can
automatically retrieve packets, so igmp span-vlan doesn’t need to be configured in
multicast VLAN. However, if upstream direction multicast messages go through non-
multicast VLAN, the VLAN’s igmp span-vlan must be configured, if going through dual-
layer VLAN, igmp span-vlan is configured in SVLAN.
For example:
acl number 1
rule 1 permit any 61.166.57.0 0.0.0.255 any any
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 31
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 32
Confidential▲
The default system time of C600 is Greenwich time, to guarantee that the system time
and EMS time are consistent or close, modify according to local timezone:
ZXAN#show clock
08:50:05 UTC Thu Jan 18 2018
ZXAN#config t
Enter configuration commands, one per line. End with CTRL/Z.
ZXAN(config)#clock timezone Beijing 8
ZXAN(config)#show clock
16:50:44 Beijing Thu Jan 18 2018
ZXAN(config)#exit
ZXAN#clock set 8:51:30 ?
MM-DD-YYYY Current date from 1-1-2001 to 12-31-2037
ZXAN#clock set 8:51:30 1-18-2018 ?
<cr>
ZXAN#clock set 8:51:30 1-18-2018
ZXAN#show clock
08:51:31 Beijing Thu Jan 18 2018
ZXAN#Config t
ZXAN(config)#ntp enable
ZXAN(config)#ntp poll-interval 6
ZXAN(config)#ntp server 10.10.10.10 priority 1 ---------------NTP server 1
ZXAN(config)#ntp server 10.10.10.20 priority 5---------------NTP server 2
Note: NTP clock synchronization requires timezone of the NE and that of the server to
be consistent, and the interval is within 1000s, otherwise, clock fails to be synchronized.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 33
Confidential▲
Three packets refer to broadcast packet, unknown unicast packet, unknown multicast
packet respectively:
ZXAN(config)#show eth-switch stormcontrol
pkttype limitnum(unit:pps)
broadcast 100
unknowncast 100
multicast unlimited
The delay down function of C600 uplink port supports to configure based on ports, when
configuring, you need to enter the port mode to configure, and the system’s default
value is 120s:
ZXAN(config)#interface xgei-1/18/1
ZXAN(config-if-xgei-1/18/1)#holdtime 100
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 34
Confidential▲
Choose the ONU type profile that you need to configure, HGU doesn’t need to configure eth
interface, while SFU need to configure it. Its configuring method is the same as C300.
ZXAN#con t
ZXAN(config)#pon
ZXAN(config-pon)#onu-type ZTE-1866 epon description 4GE,2POTS,4WLAN
ZXAN(config-pon)#onu-type ZTE-F220 gpon
ZXAN(config-pon)#onu-type GPON-E8C gpon max-tcont 7 max-gemport 8 max-flow-perswitch 1
ZXAN(config-pon)#onu-type ZTEG-612 gpon description F612-2FE
ZXAN(config-pon)#onu-type 4FE2POS4WLAN gpon
ZXAN(config-pon)#onu-type 8FE8POS4WLAN gpon
ZXAN(config-pon)#onu-type ZTEG-F2866 gpon
ZXAN(config-pon)#onu-type-if ZTE-F220 eth_0/1
ZXAN(config-pon)#onu-type-if ZTE-F220 eth_0/2
ZXAN(config-pon)#onu-type-if ZTE-F220 eth_0/3
ZXAN(config-pon)#onu-type-if ZTE-F220 eth_0/4
ZXAN(config-pon)#onu-type-if ZTEG-F2866 eth_0/1
ZXAN(config-pon)#onu-type-if ZTEG-F2866 eth_0/2
ZXAN(config-pon)#onu-type-if ZTEG-F2866 eth_0/3
ZXAN(config-pon)#onu-type-if ZTEG-F2866 eth_0/4
ZXAN(config-pon)#onu-type ZTEG-F600 gpon description 4FE
ZXAN(config-pon)#onu-type ZTEG-F620 gpon description 4FE,2POTS max-tcont 8 max-gemport 32 max-flow-perswitch 8
ZXAN(config-pon)#onu-type ZTEG-F660 gpon description 4FE,2POTS1WIFI
ZXAN(config-pon)#onu-type-if ZTEG-F600 eth_0/1
ZXAN(config-pon)# onu-type-if ZTEG-F600 eth_0/2
ZXAN(config-pon)# onu-type-if ZTEG-F600 eth_0/3
ZXAN(config-pon)#onu-type-if ZTEG-F600 eth_0/4
ZXAN(config-pon)#onu-type-if ZTEG-F620 eth_0/1
ZXAN(config-pon)#onu-type-if ZTEG-F620 eth_0/2
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 35
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 36
Confidential▲
Choose the GPON TCONT bandwidth profile that you need to configure, and the
configuring method is the same as C300.
ZXAN#con t
ZXAN(config)#gpon
profile tcont T1-1G type 1 fixed 1000000
profile tcont GPON-BW type 3 assured 10240 maximum 1024000
profile tcont 10M type 2 assured 10240
profile tcont 100M type 2 assured 102400
profile tcont 10GPON-BW type 3 assured 24567 maximum 1024000
profile tcont 20M-GPON type 3 assured 10240 maximum 20480
profile tcont T1-1G type 1 fixed 1000000
profile tcont GPON-BW type 3 assured 10240 maximum 1024000
profile tcont 10M type 2 assured 10240
profile tcont 100M type 2 assured 102400
profile tcont 10GPON-BW type 3 assured 24567 maximum 1024000
profile tcont 20M-GPON type 3 assured 10240 maximum 20480
profile tcont FTTHVOIPUP1M type 4 maximum 1024
profile tcont FTTBVOIPUP20M type 4 maximum 20480
profile tcont FTTH_UN type 4 maximum 25600
profile tcont FTTH_HG_TF type 4 maximum 102400
profile tcont FTTH_HGU_10M type 2 assured 15360
profile tcont FTTH_HGU_8M type 2 assured 12288
profile tcont FTTH_HGU_20M type 2 assured 30720
profile tcont FTTH_HGU_30M type 2 assured 46080
profile tcont FTTH_HGU_40M type 2 assured 61440
profile tcont FTTH_HGU_50M type 2 assured 76800
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 38
Confidential▲
Profile
Choose downstream bandwidth profile that you need to create, and under config
mode:
ZXAN#con t
ZXAN(config)#
traffic-profile FTTHVOIPDOWN1M cir 1024 cbs 512 pir 10240 pbs 1023
traffic-profile FTTBVOIPDOWN20M cir 20480 cbs 512 pir 22480 pbs 1023
traffic-profile FTTH_UN cir 5120 cbs 512 pir 1651200 pbs 1023
traffic-profile FTTH_HG_TF cir 665600 cbs 512 pir 1331200 pbs 1023
traffic-profile FTTH_HGU_10M cir 15360 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_8M cir 12288 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_20M cir 30720 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_30M cir 46080 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_50M cir 76800 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_200M cir 204800 cbs 512 pir 256000 pbs 1023
The following command can be used to view:
C600#show qos traffic-profile
No.1 profile :TEST22
No.2 profile :LC_ZTE_100M
At present, VOIP configurations on C6xx aiming at IP, VLAN configuration need to use
profiles, but do not support non-profile configurations
The IP address of onu ip-host can be configured through binding the IP profile.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 39
Confidential▲
Create IP profile:
For VOIP service, you need to configure VLAN-related properties of onu ip-host
through binding VLAN profile.
ZXAN(config-gpon)#onu profile vlan voip-vlan tag-mode tag cvlan 4001 pri 6----Create a vlan
profile, with cvlan as 100, priority as 6
ZXAN(config)#gpon
ZXAN(config-gpon)#onu profile sip test-sip ? ------Create a sip protocol profile, and fill in parameters
according to needs
dns1 DNS1
media Media
registrar Registrar
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 40
Confidential▲
ss SS vendor
<cr>
ZXAN(config-gpon)#onu profile mgc test-h248 -----------Create MGC profile of H248 or MGCP, and fill
in parameters according to needs
media Media
port Port
ss SS vendor
version Version
<cr>
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 41
Confidential▲
ZXAN#con t
ZXAN(config)#interface xgei-1/19/1
ZXAN(config-if-xgei-1/19/1)#switchport vlan 1000-1999, 3751,3801,4070 tag
ZXAN(config-if-xgei-1/19/1)#exit
ZXAN#con t
ZXAN(config)#interface smartgroup1
ZXAN(config-if-smartgroup1)#switchport vlan 1000-1999, 3751,3801,4070 tag
ZXAN(config-if-smartgroup1)#exit
ZXAN#config t
Enter configuration commands, one per line. End with CTRL/Z.
ZXAN(config)#interface gpon_olt-1/1/1
ZXAN(config-if-gpon_olt-1/1/1)#no shutdown
C600 can query un-authenticated ONUs through show pon onu uncfg, after SN or LOID
is queried, perform registration configuration, or pre-configuration.
ZXAN(config-if-gpon_olt-1/1/1)#onu 1 type 4FE2POS4WLAN loid GPONTEST3
ZXAN(config-if-gpon_olt-1/1/1)#onu 2 type ZTEG-F2866 loid LG0000000010
ZXAN(config-if-gpon_olt-1/1/1)#onu 3 type 4FE2POS4WLAN loid XGPONTEST1
ZXAN(config-if-gpon_olt-1/1/1)#onu 4 type 4FE2POS4WLAN loid test1
ZXAN(config-if-gpon_olt-1/1/1)#onu 5 type 4FE2POS4WLAN loid LG2041178903
ZXAN(config-if-gpon_olt-1/1/1)#onu 6 type 4FE2POS4WLAN loid test2
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 42
Confidential▲
Tcont and gemport service models are decided according to on-site requirements, it can
be single-tcont and single-gemport, and can also be multi-tcont, multi-gemport. C600
doesn't support gemport rate-limit, but vport or service-port rate-limit can be used. Here,
only consider tcont:gemport as 1:1.
Single-tcont single-gemport:
ZXAN(config)#interface gpon_onu-1/1/1:1
ZXAN(config-if-gpon_onu-1/1/1:1)#tcont 1 profile 10GPON-BW
ZXAN(config-if-gpon_onu-1/1/1:1)#gemport 1 tcont 1
Multi-tcont multi-gemport:
ZXAN(config)#interface gpon_onu-1/1/1:6
ZXAN(config-if-gpon_onu-1/1/1:6)#tcont 1 name Tl1DefaultCreate profile 10GPON-BW
ZXAN(config-if-gpon_onu-1/1/1:6)#sn-bind disable
ZXAN(config-if-gpon_onu-1/1/1:6)#gemport 1 name Tl1OpVlan46 tcont 1
ZXAN(config-if-gpon_onu-1/1/1:6)#gemport 2 name IPTV tcont 1
ZXAN(config-if-gpon_onu-1/1/1:6)#gemport 3 name Tl1OpVlan684 tcont 1
ZXAN(config-if-gpon_onu-1/1/1:6)#gemport 4 name Tl1OpVlan4001 tcont 1
ZXAN(config-if-gpon_onu-1/1/1:6)#gemport 5 name Tl1OpVlan4070 tcont 1
C600 ONU remote management only supports simplified service configuration mode,
service flow mapping adopts SERVICE commands, while user port uses vlan port or
multicast vlan commands, to complete configuration of unicast or multicast service.
Single-tcont, single-gemport:
pon-onu-mng gpon_onu-1/1/1:1
vlan port veip_1 mode trunk
vlan port veip_1 vlan 41,43,45-46
service Tl1OpVlan46 gemport 1 vlan 46
service Tl1OpVlan45 gemport 1 vlan 45
service Tl1OpVlan41 gemport 1 vlan 41
service Tl1OpVlan43 gemport 1 vlan 43
Multi-tcont, multi-gemport:
ZXAN(config)#pon-onu-mng gpon_onu-1/1/1:6
ZXAN(config-gpon-onu-mng)#mvlan 4070
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 43
Confidential▲
or configure it as transparent:
ZXAN(config-gpon-onu-mng)#vlan port veip_1 mode transparent
ZXAN(config-gpon-onu-mng)#vlan port eth_0/1 mode tag vlan 100------Configure the tag mode
Trunk mode scenario:
ZXAN(config)#pon-onu-mng gpon_onu-1/2/1:1
ZXAN(gpon-onu-mng)#vlan port eth_0/1 mode trunk----------Configure the trunk mode
ZXAN(gpon-onu-mng)#vlan port eth_0/1 vlan 101,102,103------ Configure vlan transparent under
the trunk mode
3) Configure VOIP service
After the ip profile and vlan profile are created, it can be bound with ONU IP-HOST,
to complete corresponding configurations. And profile configuration mode is suggested
to use with simplified configuration together.
ZXAN(config)#pon-onu-mng gpon-onu_1/2/1:1
IP address can be static or DHCP mode, at present, support three modes: DHCP,
PPPOE and static:
Configuration example:
ZXAN(config)#pon-onu-mng gpon_onu-1/2/1:1
ZXAN(gpon-onu-mng 1/2/1:1)#voip protocol ? ---Configure the VOIP protocol supported by the ONU
(parameters can be configured according to supporting states of the ONU), after you have chosen the
protocol made, the POTS port needs to be bound to the corresponding protocol profile
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 45
Confidential▲
none None
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 46
Confidential▲
The rate profile must be created in advance, like previous chapter of creating service-
port or vport rate-limit bandwidth profile.
Limit rate for service-port:
ZXAN(config)#interface vport-1/1/1.1:1
ZXAN(config-if-vport-1/1/1.1:1)#service-port 1 user-vlan 41 vlan 1001 svlan 1999 egress
FTTH_HGU_200M -----------Limit rate for each service-port.
Limit rate for vport:
ZXAN(config)#interface vport-1/1/1.1:1
ZXAN(config-if-vport-1/1/1.1:1)#qos traffic-policy FTTH_HGU_200M direction egress---Limit rate for
the whole vport.
Configuring vport-mode or not under the PON port doesn’t matter, but under the
interface gpon-onu, be sure to modify vport mode before you create a gemport,
otherwise, after the gemport is created, it can be configured for the first time, later, it
can’t be modified.
ZXAN(config-if-gpon_olt-1/2/4)#onu 2 typeZTE-F601 sn ZTEG12345678
ZXAN(config-if-gpon_olt-1/2/4)#exit
ZXAN(config)#interface gpon_onu-1/2/4:2
ZXAN(config-if-gpon_onu-1/2/4:2)#vport-mode manual
ZXAN(config-if-gpon_onu-1/2/4:2)#tcont 1 profile UP-10M
ZXAN(config-if-gpon_onu-1/2/4:2)#tcont 2 profile UP-10M
ZXAN(config-if-gpon_onu-1/2/4:2)#gemport 1 tcont 1
ZXAN(config-if-gpon_onu-1/2/4:2)#gemport 2 tcont 2
ZXAN(config-if-gpon_onu-1/2/4:2)#vport-map 1 1 vlan 100
ZXAN(config-if-gpon_onu-1/2/4:2)#vport-map 1 2 vlan 200
ZXAN(config-if-gpon_onu-1/2/4:2)#exit
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 47
Confidential▲
ZXAN(config)#interface vport-1/2/4.2:1
ZXAN(config-if-vport-1/2/4.2:1)#service-port 1 user-vlan 100 vlan 100
ZXAN(config-if-vport-1/2/4.2:1)#service-port 2 user-vlan 50 vlan 200
Show the configuration effect:
ZXAN(config)#show running-config-interface gpon_onu-1/2/4:2
!<if-intf>
interface gpon_onu-1/2/4:2
$
!</if-intf>
!<xpon>
interface gpon_onu-1/2/4:2
vport-mode manual
tcont 1 profile UP-10M
tcont 2 profile UP-10M
gemport 1 tcont 1
gemport 2 tcont 2
vport 1 map-type vlan
vport-map 1 1 vlan 100
vport-map 1 2 vlan 200
$
pon-onu-mng gpon_onu-1/2/4:2
$
!</xpon>
ZXAN(config)#show running-config-interface vport-1/2/4.2:1
!<if-intf>
interface vport-1/2/4.2:1
$
!</if-intf>
!<MSAN>
interface vport-1/2/4.2:1
service-port 1 user-vlan 100 vlan 100
service-port 2 user-vlan 50 vlan 200
$
!</MSAN>
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 48
Confidential▲
Different from GPON, EPON needs to first set authentication mode. At present, C600
cancels onu-authentication-mode command in EPON under the global mode, but change
related configuration into commands under the PON port mode, auth-ctrl loid
enable/disable and auth-ctrl sn enable/disable.
1)When both loid and sn are disabled, correspond to MAC authentication mode; if
just loid enabled, correspond to hybrid mode of MAC+LOID; after both loid and sn are
enabled, correspond to hybrid authentication mode.
2)There is no separate loid authentication mode, sn authentication mode can only be
enabled under the circumstances that loid is enabled, that is, there is no separate sn
authentication mode, and do not support to use sn mode to add onu.
3)Under the circumstances that loid and sn are enabled, it is equivalent to the
function of auth-sn-as-loid.
4)Silence is enabled by default, and no switches can be set, that is to say, do not
support to disable silence.
Configuration example:
ZXAN(config-if-epon_olt-1/2/1)#auth-ctrl ?
ZXAN(config-if-epon_olt-1/2/1)#auth-ctrl loid ?
disable Disable
enable Enable
<cr>
disable Disable
enable Enable
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 49
Confidential▲
There are already a part of default ONU type profiles on C600, line cards can create
once again according to your own needs.
ZXAN(config)#pon
ZXAN(config-pon)#onu-type-if ZTE-F420 pots_0/1-2 -------Configure No. 1-2 POTS ports in Slot 0; the
slot of F420’s POTS port must also be configured as 0, to be able to configure through OLT remote
extended OAM;
ZXAN(config-pon)#show onu-type-if ZTE-F420 --------The port type and quantity of configured ONU
type profile can be viewed
The system’s default ONU type profiles are listed as following, and you can add other
ONU types according to your own requirements:
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 50
Confidential▲
Precautions
1. ONU types that the system creates by default can’t be deleted and modified, and
user interfaces can’t be added / deleted for them.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 51
Confidential▲
The ONU bandwidth profile in the binding status can not be deleted.
Downstream VPORT or service-port rate-limit profile of EPON services are the same
as downstream rate-limit profile of GPON services, which can also be called together.
Choose the downstream bandwidth profile that you need to create, under config
mode:
ZXAN#con t
ZXAN(config)#
traffic-profile FTTHVOIPDOWN1M cir 1024 cbs 512 pir 10240 pbs 1023
traffic-profile FTTBVOIPDOWN20M cir 20480 cbs 512 pir 22480 pbs 1023
traffic-profile FTTH_UN cir 5120 cbs 512 pir 1651200 pbs 1023
traffic-profile FTTH_HG_TF cir 665600 cbs 512 pir 1331200 pbs 1023
traffic-profile FTTH_HGU_10M cir 15360 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_8M cir 12288 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_20M cir 30720 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_30M cir 46080 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_50M cir 76800 cbs 512 pir 102400 pbs 1023
traffic-profile FTTH_HGU_200M cir 204800 cbs 512 pir 256000 pbs 1023
The following command can be used to view:
C600#show qos traffic-profile
No.1 profile: FTTHVOIPDOWN1M
No.2 profile FTTBVOIPDOWN20M
No.3 profile FTTH_HGU_20M
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 52
Confidential▲
EPON uplink VLAN configuration is as the same as GPON, just add the corresponding
VLAN to the uplink port or switchport. For specific configuration, please refer to Section 4
in Chapter 4.
ZXAN(config)#interface epon_olt-1/2/1
ZXAN(config-if-epon_olt-1/4/1)#speed ? -----------Choose the working mode needed, generally,
symmetrical and asymmetric needs to be modified, if 1G ONU is connected, it doesn’t need to be
modified.
1G 1G
Precautions
1) A single EPON port supports to register at most 64 ONUs, while a single 10G EPON port
supports to register at most 128 ONUs.
2) During actual applications of EPON, the quantity of ONUs under each PON needs to
confirmed through combining specific service and requirements of the customer. When
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 53
Confidential▲
planning, try to ensure that types of ONUs connected under one PON port are the same, to
facilitate unified distribution of bandwidth, VLAN and so on.
Under the EPON ONU interface, because it doesn’t need to configure service flows and
other configurations like GPON, it only needs to configure description information and
upstream bandwidth rate-limit and so on.
ZXAN(config)#interface epon_onu-1/2/1:1
ZXAN(config-if-epon_onu-1/2/1:1)#description test-12345678
ZXAN(config-if-epon_onu-1/2/1:1)#sla-profile 500M vport 1
If there are no special requirements, because all are transparently transmitted under
the EPON HGU remote management, there is no need to perform any configuration.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 54
Confidential▲
pon-onu-mng epon_onu-1/3/6:1
auto-config voip enable
voip ip-address 10.132.148.122 mask 255.255.248.0 slot 1
voip rtp-tid tid-number 2 prefix RTP/ begin-digit 0 align enable digit-length
1 slot 1
voip user-tid 1 beginid 1 tid-num 1 prefix A begin-digit 0 align enable digit-
length 1 slot 1
multicast vlan tag-strip port eth_0/1 enable
multicast vlan tag-strip port eth_0/2 enable
voip-module fax-profile apply T38
voip-module global-profile apply vlan voipvlan ip f420-ip
voip-module protocol-profile apply h248 f420-2
Configure multicast service
ZXAN(config)#pon-onu-mng epon_onu-1/2/1:1
ZXAN(config-epon-onu-mng)#multicast vlan port eth_0/1 add vlanlist 4070--Configure multicast
vlan
ZXAN(config-epon-onu-mng)#multicast vlan tag-strip port eth_0/1 enable--Set multicast VLAN
stripping
ZXAN(config-epon-onu-mng)#multicast fastleave enable -------Configure fastleave
ZXAN(config)#interface vport-1/2/1.1:1 ----------------Enter the vport mode, note that EPON only has
vport 1
ZXAN(config-if-vport-1/2/1.1:1)#service-port 1 user-vlan 41 vlan 33 svlan 584 new-cos 0
ZXAN(config-if-vport-1/2/1.1:1)#service-port 2 user-vlan 43 vlan 2500 svlan 2834 new-cos 5
ZXAN(config-if-vport-1/2/1.1:1)#service-port 3 user-vlan 45 vlan 3499 svlan 3082 new-cos 6
ZXAN(config-if-vport-1/2/1.1:1)#service-port 4 user-vlan 46 vlan 3900
ZXAN(config-if-vport-1/2/1.1:1)#service-port 5 user-vlan 4070 vlan 4070
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 55
Confidential▲
For EPON ONUs, upstream direction rate-limit uses SLA profile, configured under the
interface epon_onu, while downstream rate-limit uses vport or service-port, configured
under the vport mode.
vport rate-limit mode
Traffic-policy rate-limit mode:
Policy rate-limit mode supports to configure upstream/downstream:
ZXAN(config-if-vport-1/2/2.10:1)#qos traffic-policy FTTH_HGU_20M direction egress
Shaping rate-limit mode doesn’t need to configure upstream/downstream:
ZXAN(config-if-vport-1/2/2.10:1)#qos traffic-shaping FTTH_HGU_20M
2)service-port rate-limit mode
Use service-port rate-limit mode as below, mainly limit rate at the egress direction:
ZXAN(config-if-vport-1/2/2.10:1)#service-port 1 user-vlan 100 vlan 100 svlan 1000 egress
FTTH_HGU_20M
PPPOE+ of the C600 equipment is synchronized with C300V2.1.0, supporting global profiled
configuration, VLAN-based profiled configuration and ONU-based PPPOE+ port location.
ZXAN(config-portloc-operator-profile-profileName)#pppoe-intermediate-agent ?
ZXAN(config-portloc-operator-profile-profileName)#pppoe-intermediate-agent enable
ZXAN(config-portloc-operator-profile-profileName)#pppoe-intermediate-agent trust ?
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 56
Confidential▲
ZXAN(config-portloc-operator-profile-profileName)#pppoe-intermediate-agent remote-id ?
vlan total: 1
110
ZXAN(config)#
The option82 of the C600 equipment is synchronized with C300V2.1.0, supporting global profiled
configuration, VLAN-based profiled configuration and ONU-based option82 port location
ZXAN(config-portloc-operator-profile-profileName)#dhcpv4-l2-relay-agent ?
ZXAN(config-portloc-operator-profile-profileName)#dhcpv4-l2-relay-agent enable
ZXAN(config-portloc-operator-profile-profileName)#dhcpv4-l2-relay-agent trust ?
ZXAN(config-portloc-operator-profile-profileName)#dhcpv4-l2-relay-agent remote-id ?
ZXAN(config)#dhcpv4-l2-relay-agent vlan 110 -----Enable (disable) the port location function of dhcp
based on vlan.
vlan total: 1
110
ZXAN(config)#
When adopting ONU interface to configure port location format, except global configurations, you still
need to configure combined format under the ONU interface.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 58
Confidential▲
DHCPv4 DHCPv4
Precautions
1)Following configuration examples just show the methods to configure basic port
location function, while for details, refer to Command Manual.
2) By default, port location format profile supported by the system is China Telecom
format, and the profile can be replaced, and can also be self-defined.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 59
Confidential▲
ZXAN(config)#interface gpon_olt-1/1/1
ZXAN(config-if-gpon_olt-1/1/1)#show this
!<MSAN>
description C600-TESTING
no shutdown
!</MSAN>
!<xpon>
onu 1 type 4FE2POS4WLAN loid GPONTEST3
onu 2 type ZTEG-F2866 loid LG0000000010
onu 3 type 4FE2POS4WLAN loid XGPONTEST1
onu 4 type 4FE2POS4WLAN loid test1
onu 5 type 4FE2POS4WLAN loid LG2041178903
onu 6 type 4FE2POS4WLAN loid test2
!</xpon>
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 60
Confidential▲
configuration
interface vport-1/1/1.5:2
$
!</if-intf>
!<MSAN>
interface vport-1/1/1.5:2
service-port 2 user-vlan 2613 vlan 2613 svlan 3801
service-port 2 description IPTV
igmp max-groups 8
$
igmp mvlan 4070
receive-port vport-1/1/1.5:2
$
!</MSAN>
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 62
Confidential▲
!</MSAN>
$
!</if-intf>
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 64
Confidential▲
An alarm 723942 ID 643 level 3 occurred at 15:04:36 12-21-2017 sent by ZXAN PFU-1/1/0
%GPONRM% Onu Uni lan los (rack 1 shelf 1 slot 1 port 1 onu 1 uni 1)
An alarm 722445 ID 642 level 2 occurred at 15:04:36 12-21-2017 sent by ZXAN PFU-1/1/0
%GPON% GPON alarm link olt losi (rack 1 shelf 1 slot 1 port 1 onu 4)
An alarm 722605 ID 641 level 1 occurred at 15:04:36 12-21-2017 sent by ZXAN PFU-1/1/0
%GPON% GPON alarm channel los (rack 1 shelf 1 slot 1 port 1 channel 2)
An alarm 722605 ID 514 level 1 occurred at 15:30:28 12-20-2017 sent by ZXAN PFU-1/2/0
%GPON% GPON alarm olt los (rack 1 shelf 1 slot 2 port 1 Probable Cause: LastOnuOffline)
An alarm 723942 ID 637 level 3 occurred at 14:08:57 12-21-2017, cleared at 15:03:46 12-21-2017 sent by ZXAN PFU-1/1/0
%GPONRM% Onu Uni lan los (rack 1 shelf 1 slot 1 port 1 onu 1 uni 1)
An alarm 722445 ID 636 level 2 occurred at 14:08:57 12-21-2017, cleared at 15:03:46 12-21-2017 sent by ZXAN PFU-1/1/0
%GPON% GPON alarm link olt losi (rack 1 shelf 1 slot 1 port 1 onu 4)
An alarm 722605 ID 635 level 1 occurred at 14:08:57 12-21-2017, cleared at 15:03:46 12-21-2017 sent by ZXAN PFU-1/1/0
%GPON% GPON alarm channel los (rack 1 shelf 1 slot 1 port 1 channel 2)
An alarm 722605 ID 633 level 1 occurred at 14:08:10 12-21-2017, cleared at 14:08:52 12-21-2017 sent by ZXAN PFU-1/1/0
%GPON% GPON alarm olt los (rack 1 shelf 1 slot 1 port 1 Probable Cause: LastOnuOffline)
... . . .
A notification 360107 ID 647 level 7 occurred at 17:46:23 12-21-2017 sent by ZXAN MPU-1/11/0
%ADM-MGR% User logout! User-account zte logout, access type CLI, VTY NO. 1, IP address 198.24.103.92.
A notification 360106 ID 646 level 7 occurred at 17:26:50 12-21-2017 sent by ZXAN MPU-1/11/0
%ADM-MGR% User login! User-account zte login, access type CLI, VTY NO. 1, IP address 198.24.103.92.
.. . . . .
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 65
Confidential▲
The Snmp log record is Disable by default, first, you need to Enable it:
Under config mode, configure snmp-server log enable all
Command: show logging buffer snmplog
For example:
ZXAN(config)#snmp-server log enable all
ZXAN(config)#show logging buffer snmplog
Log acceptance: on
Log matched: 2
Log in buffer: 2
Buffer occupied: 0.30%
Log file path: /datadisk0/LOG/SNMP/
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 66
Confidential▲
ZXAN(config)#logging on
ZXAN(config)#syslog level notifications
ZXAN(config)#syslog-server facility syslog
ZXAN(config)#syslog-server facility local0 ------Configure corresponding facility
ZXAN(config)#syslog-server source ipv4 169.1.5.5 //OLT IP
ZXAN(config)#syslog-server host 192.168.0.100 alarmlog cmdlog snmplog //Address of the syslog server
ZXAN(config)#syslog hostname-field ip-addr
ZXAN(config)#logging ftp notifications vrf mng 168.1.70.100 target target zxralarm.log /*
“zxralarm.log”is the name of the file for saving logs*/----This configuration is optional
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 67
Confidential▲
--------------------------------------------------------------------------------
Optical Transmitter Information:
--------------------------------------------------------------------------------
Laser-Rate : 25 (100Mb/s) TxPower : 5.247(dbm)
Wavelength : 1577 (nm) TxBias-Current: 100.400(mA)
Laser-Rate : N/A TxPower : N/A
Wavelength : N/A TxBias-Current: N/A
--------------------------------------------------------------------------------
Optical Module Alarm Threshold:
--------------------------------------------------------------------------------
RxPower-Upper : 3 (dbm) RxPower-Lower : -34(dbm)
TxPower-Upper : 9 (dbm) TxPower-Lower : -14(dbm)
Bias-Upper : 131(mA) Bias-Lower : 0(mA)
Voltage-Upper : 7 (v) Voltage-Lower : 0(v)
Temperature-Upper: 90 (c) Temperature-Lower: -45(c)
Module-Class : default
ZXAN(config)#show equipment
Slot CfgTpye RealType HardVer McuVer BootVer EpldVer M-Code SN
-------------------------------------------------------------------------------
1 GFBH GFBHK V1.0.0 V1.0.0 V1.0.0 V1.1 000300 711417700006
2 GFXH GFXHK V1.0.0 V1.0.0 V1.0.0 V1.4 000300 713199119911
10 SFUL SFUL V1.0.0 N/A V1.0.0 V1.6 000100 710911000010
11 SFUL SFUL V1.0.0 N/A V1.0.0 V1.6 000100 710911000034
19 XFTO XFTOB V1.0.0 V1.0.0 V1.0.0 V1.1 000100 710802000020
20 PRVR PRVR V1.0.0 V1.0.2 N/A N/A 000001 710647400014
22 PRVR PRVR V1.0.0 V1.0.2 N/A N/A 000001 710647400010
23 FCVD FCVD V1.0.0 V1.0.0P N/A N/A 000101 712221400026
0T1
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 68
Confidential▲
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 69
Confidential▲
7.3.8 Show protocol message statistics entering the main control’s CPU
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 70
Confidential▲
icmp 0 0 0 0 0 -
ssh 0 0 0 0 0 -
other 0 0 0 0 0 -
igmp 0 0 0 0 0 -
dhcp 0 0 0 0 0 -
pppoe 0 0 0 0 0 -
snmp 0 0 0 0 0 -
telnet 0 0 0 0 0 -
bfd 0 0 0 0 0 -
stp 0 0 0 0 0 -
lacp 0 0 0 0 0 -
lldp 0 0 0 0 0 -
rip 0 0 0 0 0 -
bgp 0 0 0 0 0 -
ospf 0 0 0 0 0 -
isis 0 0 0 0 0 -
ldp 0 0 0 0 0 -
cfm 0 0 0 0 0 -
ipv6_icmp 0 0 0 0 0 -
ipv6_dhcp 0 0 0 0 0 -
raps 0 0 0 0 0 -
mld 0 0 0 0 0 -
erps 0 0 0 0 0 -
ieee1588 0 0 0 0 0 -
pim 0 0 0 0 0 -
ntp 0 0 0 0 0 -
dhcp_bcast 0 0 0 0 0 -
padi 0 0 0 0 0 -
arp_networ 0 0 0 0 0 -
k_side
arp_user_s 2906 0 0 1 0 12:21:10
ide 12/18/2018
ipv6_rs_ne 0 0 0 0 0 -
twork_side
ipv6_rs_us 0 0 0 0 0 -
er_side
ipv6_ra_ne 0 0 0 0 0 -
twork_side
ipv6_ra_us 0 0 0 0 0 -
er_side
ipv6_ns_ne 0 0 0 0 0 -
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 71
Confidential▲
twork_side
ipv6_ns_us 0 0 0 0 0 -
er_side
ipv6_na_ne 0 0 0 0 0 -
twork_side
ipv6_na_us 0 0 0 0 0 -
er_side
7.3.9 Show protocol message statistics entering the line card’s CPU
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 72
Confidential▲
pim 0 0 0 0 0 -
ntp 0 0 0 0 0 -
dhcp_bcast 0 0 0 0 0 -
padi 0 0 0 0 0 -
arp_networ 0 0 0 0 0 -
k_side
arp_user_s 0 0 0 0 0 -
ide
ipv6_rs_ne 0 0 0 0 0 -
twork_side
ipv6_rs_us 0 0 0 0 0 -
er_side
ipv6_ra_ne 0 0 0 0 0 -
twork_side
ipv6_ra_us 0 0 0 0 0 -
er_side
ipv6_ns_ne 0 0 0 0 0 -
twork_side
ipv6_ns_us 0 0 0 0 0 -
er_side
ipv6_na_ne 0 0 0 0 0 -
twork_side
ipv6_na_us 0 0 0 0 0 -
er_side
ZXAN#
UndersizePkts:0 InErrPkts :0
BwUsingRatio :0%
Output:
Byte :305222136 Packets :921061
UcastPkts :535380 McastPkts :383833
BcastPkts :1848 PausePkts :0
DiscardPkts :0 Collisions :0
SingColls :0 MultiColls :0
OutErrPkts :0
BwUsingRatio :0%
ZXAN#reload ?
slot Reload the designated slot
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 74
Confidential▲
ZXAN#reload system ?
force Force mode
ZXAN#reload system force ?
LINE The description of reload reason (max be 63 characters)
<cr>
ZXAN#reload system force
[shelf 1, slot 1]
BoardType I2C Addr Description Status Minor Major Fatal Overheat Temper
-------------------------------------------------------------------------
GFBH 0 1 cpu Normal 100 108 115 120 48
GFBH 0 2 np temp Normal 100 108 115 120 64
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 75
Confidential▲
[shelf 1, slot 2]
BoardType I2C Addr Description Status Minor Major Fatal Overheat Temper
-------------------------------------------------------------------------
GFXH 0 1 cpu Normal 100 108 115 120 47
GFXH 0 2 np temp Normal 100 108 115 120 58
ZXAN(config)#show eth-switch
%Error 140305: Incomplete command.
ZXAN(config)#show eth-switch ?
l2cp Show l2cp configuration
l2cp-brief Show l2cp brief configuration
l2cp-default Show default l2cp configuration
max-frame-length show max-frame-length configuration
stormcontrol eth-switch stormcontrol
ZXAN(config)#show eth-switch stormcontrol
pkttype limitnum(unit:pps)
broadcast 100
unknowncast 100
multicast unlimited
C600(config-pon)#rogue-onu-detect 6 enable
C600(config-pon)#rogue-onu-detect olt gpon_olt-1/6/1 locate enable auto-shutdown enable
C600(config-pon)#rog
C600(config-pon)#rogue-onu-detect ?
<1-9,12-19> Slot number
olt Configure rogue ONU detect parameter
Method to restore:
ZXAN(config)#interface gpon_olt-1/6/1
C600(config-if-gpon_olt-1/6/1)#onu-sn enable -----------------Dispatch the command to notify the ONU
to laser.
ZXAN(config)#show terminal
Line: 66, Location: 136.1.1.111, Type: "vt100"
Length: 36 lines, Width: 168 columns
Telnet idle-timeout: 00:10:00
Telnet absolute-timeout: 1d00h00m
Baud rate (TX/RX):115200/115200
Capabilities: none
Time since activation: 00:06:31
Editing: enabled
History: enabled, History size: 10
Telnet IPv4 ACL name:
Telnet IPv6 ACL name:
Telnet server: enable, Listen port: 23
Telnet DSCP value:
Telnet max-link: 15
An ODB port is added on the switching & control card of C600, and it is a port
connected under the Console port on the switching & control card, mainly used for
connection of the line card’s serial port, which can be understood that users can log on
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 77
Confidential▲
the serial port of the line card through this port. We can enable or disable the ODB debug
port of a certain slot via CLI .
Note: Before you enable the ODB debug port of a certain slot, please be sure to disable it
first, to avoid from logging in the line card set last time.
ZXAN#show odb-switch
ODB-switch enable on slotno:2
And then connect the serial port cable to the ODB port, login this serial port can log in to
the specified line card’s serial port .
When the ODB port is connected via a serial port cable, it also uses 115200 baud rate.
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 78
Confidential▲
When the distance exceeds 20KM, the distance of optical fiber needs to be modified:
ZXAN(config-if-gpon_olt-1/1/1)#fiber-distance ?
<0-400> Min distance, unit is 100m, only for GPON
ZXAN(config-if-gpon_olt-1/1/1)#fiber-distance 100 ?
<200-600> Max distance, unit is 100m
ZXAN(config-if-gpon_olt-1/1/1)#fiber-distance 100 300 ?
<cr>
ZXAN(config-if-gpon_olt-1/1/1)#fiber-distance 100 300
card
ZXAN(config)#control-panel
ZXAN(config-control-panel)#
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 79
Confidential▲
ZXAN (config-control-panel)end
ZXAN(control-panel)#snatch-cpu-packet slot 3 enable //Enable the line card’s cpu packet capturing
function
ZXAN (control-panel)end
ZTE Confidential Proprietary © 2019 ZTE Corporation. All rights reserved. Page 80