913 pH Meter

2.913.0010

Portable two-channel pH measuring instrument for measuring pH/mV and temperature. You will
be optimally equipped for measurements in the field with this battery-operated measuring
instrument.

Portable pH meter with built-in battery pack and two galvanically isolated pH measuring
inputs
Analog pH measuring input for Metrohm standard pH electrodes
Digital pH measuring input for the intelligent pH electrodes from Metrohm
Robust, water-tight and dust-tight housing (IP67) for hard outdoor and laboratory use
LCD color display with background illumination for simple legibility of the results
USB interface for simple data export to PC or printer
Large internal memory (10,000 data sets)
Pin-protected User and Expert modes, prevents unwanted parameter changes
GLP-compliant printout and data export with User ID and timestamp

Phạm vi giao hàng 2.913.0010

Qt. Order no. Description

Metrohm AG 1/8
Qt. Order no. Description

1 PCS 1.913.0010 913 pH Meter

pH/mV and temperature measurement for routine use in the laboratory


and on the road.

pH or mV and temperature can be measured in parallel with one analog


and one intelligent sensor and output to a large colour display. Important
information such as charge state, user, IDs can be clearly seen at a glance.
A PIN-protected expert mode protects against unintentional changes of
different parameters.

The meter is furnished with an accumulator for mobile use that can be
charged practically anywhere. It naturally also satisfies the requirements
of IP67.

A stand plate allows the mobile meter to be easily converted into a


laboratory meter and vice versa.

Very large measured value memory (10,000 data sets) and USB interface
(GLP-compliant printout or data export with optional management of the
data in tiBase) offer professional data handling.

1 PCS 6.2008.060 Holder for electrode storage vessel

Practical holder for fastening the electrode storage vessels to the 912,
913 or 914 pH/Conductometers.

1 PCS 6.2050.010 Carrying strap for 912/913/914

Carrying strap for 912/913/914 meters

Metrohm AG 2/8
1 PCS 6.2151.100 Adapter USB MINI (OTG) - USB A

For connecting USB instruments.

1 PCS 6.2151.110 Cable USB MINI (OTG) - USB A, 1.8 m

For connecting USB instruments.

1 PCS 6.2166.100 USB power supply unit 5.25 V / 1.53 A

USB power supply unit for 912 / 913 / 914

Efficiency Level VI

Metrohm AG 3/8
Phụ kiện tùy chọn

Order no. Description

2.142.0100 Custom Q3X thermal printer

Compact printer with USB interface for

900 Touch Control


915 KF Ti-Touch
916 Ti-Touch
917 Coulometer
877 / 848 Titrino plus
865 / 876 Dosimat plus
91X Meter (cable 6.2151.140)
Eco Dosimat / Titrator
862 Compact Titrosampler
870 KF Titrino plus
899 Coulometer

Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.

2.143.0100 EPSON TM U220B impact printer

Impact printer with USB interface for the 912/913/914 hand meter.

Power supply units: 100 - 240 V


Paper width: 76 mm

2.854.0010 854 iConnect

854 iConnect - electrode cable and measuring amplifier for intelligent


electrodes «iTrodes».

Metrohm AG 4/8
6.00226.600 Spearhead electrode with Pt1000

Maintenance-free combined pH electrode (gel electrolyte) for piercing


measurements of all types (e.g., with cheese, meat, dough) with
integrated Pt1000 temperature sensor. The electrode is stored in
saturated potassium chloride solution c(KCl) = sat. (6.2308.000) and is
not suitable for low-ion solutions. The ageing indicator gives early
indication of when the electrode needs to be replaced.

6.0224.100 Biotrode

Combined pH electrode for measurements in very small sample volumes


(>50 uL) and biological samples.

Idrolyte (6.2308.040) is used as reference electrolyte and storage solution.

6.0228.000 Solitrode with Pt1000 (fixed cable 1.2 m)

Combined pH electrode with integrated Pt1000 temperature sensor and


fixed cable (1.2 m). This electrode is suitable for routine pH
measurements in solutions that do not contain precipitates, proteins, or
sulfides. This electrode is mechanically resistant thanks to the robust
/unbreakable plastic shaft made of polypropylene and impact protection
for the glass membrane.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

6.0228.030 Solitrode with Pt1000 (IP67, fixed cable 1.2 m)

Combined pH electrode with integrated temperature sensor (Pt1000)


and fixed cable conforming to IP67 (1.2 m).
This electrode is suitable for an introduction to GLP-compliant pH
measurements in solutions that do not contain precipitates, proteins, or
sulfides. This electrode is mechanically resistant thanks to the robust
/unbreakable plastic shaft made of polypropylene and impact protection
for the glass membrane.
Additionally, this electrode offers a waterproof plug in accordance with
IP67 for mobile use with Metrohm pH meters.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

Metrohm AG 5/8
6.0258.010 Unitrode with Pt1000 (fixed cable 1.2 m, 2 mm)

Combined pH electrode with integrated Pt1000 temperature sensor and


fixed cable (1.2 m, diameter banana plug 2 mm). This electrode is
particularly suitable

for pH measurements and titrations in difficult, viscous, or alkaline


samples
at elevated temperatures
for long-term measurements

The fixed ground-joint diaphragm is insensitive to contamination.

Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.


Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte,
storage in Idrolyte.

6.0278.300 iUnitrode with Pt1000

Intelligent, combined pH electrode with integrated memory chip for


storing sensor data and Pt1000 temperature sensor. This electrode is
particularly suitable:

for pH measurements and titrations in difficult, viscous, or alkaline


samples
at elevated temperatures
for long-term measurements

The fixed ground-joint diaphragm is insensitive to contamination.

Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.


Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte,
storage in Idrolyte.
iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.

6.2001.130 Stand plate for 912/913/914

Stand plate for converting a mobile 912/913/914 pH/Conductometer


into a laboratory meter.

Metrohm AG 6/8
6.2104.600 Electrode cable for plug in head U/plug F, 2x2 mm B, 1m

For connecting electrodes with Metrohm plug-in head U to Metrohm


instruments (socket F).

6.2151.140 Y cable USB A St - USB B St - Mini B St

Y cable for connection of a USB printer to the pH/Conductometers 912 /


913 / 914. This cable allows a printer and the power supply unit to be
connected to the measuring instrument at the same time.

6.2166.500 12 V USB adapter for 912 / 913 / 914 pH/Conductometer

12 V USB adapter for 912 / 913 / 914 pH/Conductometer.

6.2307.230 Buffer solutions pH 4, 7 and 9

Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets,


colourless, box of 3 x 10 x 30 mL

Metrohm AG 7/8
6.2313.000 Electrolyte 3 mol/L KCl (1000 mL)

Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)

6.2325.000 pHit kit

Maintenance kit for pH electrodes

The kit contains:

50 mL cleaning solution
50 mL 3M KCl solution
50 mL storage solution
2 Storage vessels
Instructions for use