DC Design: Sanitary Layout Waterline Layout
DC Design: Sanitary Layout Waterline Layout
DC Design: Sanitary Layout Waterline Layout
2200
2200
1 1
SPECIFICATION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY
DESCREPANCY FOUND THEREIN.
3100
3100
4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY
RECLINERS RECLINERS
RELOCATIONS REQUIRED FOR PROPER EXECUTION OF OTHER TRADE
SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
5. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL RECEPTION RECEPTION
LOCATION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND
STRUCTURES AS VERIFIED BY THE CONTRACTOR.
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS
1100
1100
OTHERWISE SPECIFIED.
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
8. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE,
COORDINATE THE WORKS WITH THE SEWER LINE EFFLUENT DISPOSAL
POINT AND WATER LINE SERVICE CONNECTING POINT, UNLESS OTHERWISE
SPECIFIED.
D D
1 BED 1 1 BED 1
9. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
10. THE INVERT OF THE INLET PIPE OF A SEPTIC TANK SHALL BE AT A LEVEL
NOT LESS THAN 50.8mm (2") ABOVE THE INVERT OF THE OUTLET PIPE.
9000
9000
11. TO PREVENT CONTAMINATION OF UNDERGROUND WATER SOURCE NO
SEPTIC TANK SHALL BE CONSTRUCTED LESS THAN 1.20m ABOVE THE
BED 2 BED 2
WATER TABLE LEVEL.
12. ALL PIPE SIZE ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS
4100
4100
OPTICAL OPTICAL
3800
3800
UNLESS OTHERWISE SPECIFIED.
ROOM ROOM
13. MINIMUM SEWAGE PIPE SIZE SHALL BE AS FOLLOWS:
SOIL PIPE 110mm(4"Ø)
BED 3 BED 3
WASTE PIPE 63mm(2"Ø)
VENT PIPES 63mm(2"Ø)
DOWNSPOUT 63mm(2"Ø)
14. ALL PLUMBING INSTALLATION INCLUDED HEREIN SHALL BE UNDER THE
DIRECT SUPERVISION OF A DULY REGISTERED AND LICENSED MASTER BED 4 BED 4
PLUMBER. LAV
FAUCET
MATERIAL SPECIFICATIONS:
100
100
CO
FAUCET
COLD WATER LINE SHALL BE POLYPROPYLENE RANDOM (PPR) TYPE 3 PIPE, W W
LAV
"WAVIN EKOPLLASTIK" BRAND OR APPROVED EQUAL. 2 D PANTRY 2 D PANTRY
VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000,
1500 2 2
1900
1500
1900
VENTILATION VENTILATION
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.. OPEN AREA FD OPEN AREA
FITTING SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564. W W WC
TOILET
WC
SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000, 1 1
GV
TAP TO EXISTING DOWNFLOW
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL. SANITARY PIPE TAP TO EXISTING MAIN WATERLINE
FITTINGS
SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 600 II,
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
P-1 SCALE: 1:60MTS P-1 SCALE: 1:60MTS
CHECK VALVES "GREAT VOLUME"," CRANE", "KITS", OR APPROVED EQUAL.
GATE VALVES "GREAT VOLUME","CRANE", "KITS", OR APPROVED EQUAL.
WATER METER "ARAD", "ASAHI" BRAND OR APPROVED EQUAL. PLUMBING LEGEND:
IMPORTANT ENGINEER DRY SEAL PROJECT TITLE OWNER REVISIONS SHEET CONTENTS: SHEET NO.
AS SHOWN
DC DESIGN PROPOSED 2-STOREY COMMERCIAL BUILDING UNIT 14
P-01
PRC REG. TIN NO. SIGNATURE AND DATE SIGNED
LOCATION: LOT 249 MAYSAN ROAD VALENZUELA CITY
CHECKED BY DATE
PTR NO. PLACE: