DC Design: Sanitary Layout Waterline Layout

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES AND SPECIFICATIONS: 5860 5860

1. IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW EVERY PIPE


FITTING, VALVE AND APPURTENANCE. ALL SUCH ITEMS WHETHER
SPECIFICALLY MENTIONED OR NOT, OR INDICATED ON THE DRAWINGS 1930 1600 1930 1930 1600 1930
SHALL BE FURNISHED AND INSTALLED IF NECESSARY TO COMPLETE THE
SYSTEM TO THE SATISFACTION OF THE OWNER.
2. ALL PLUMBING WORKS SHALL BE INSTALLED IN ACCORDANCE WITH THE
PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, THE
REQUIREMENTS OF THE LOCAL PLUMBING INSPECTION OFFICE, PERTINENT
WAITING AREA WAITING AREA
PROVISIONS OF THE UNIFORM BUILDING CODE AND THE NATIONAL
BUILDING CODE OF THE PHILIPPINES. D D
3. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND

2200

2200
1 1
SPECIFICATION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY
DESCREPANCY FOUND THEREIN.

3100

3100
4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY
RECLINERS RECLINERS
RELOCATIONS REQUIRED FOR PROPER EXECUTION OF OTHER TRADE
SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
5. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL RECEPTION RECEPTION
LOCATION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND
STRUCTURES AS VERIFIED BY THE CONTRACTOR.
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS

1100

1100
OTHERWISE SPECIFIED.
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
8. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE,
COORDINATE THE WORKS WITH THE SEWER LINE EFFLUENT DISPOSAL
POINT AND WATER LINE SERVICE CONNECTING POINT, UNLESS OTHERWISE
SPECIFIED.
D D
1 BED 1 1 BED 1
9. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
10. THE INVERT OF THE INLET PIPE OF A SEPTIC TANK SHALL BE AT A LEVEL
NOT LESS THAN 50.8mm (2") ABOVE THE INVERT OF THE OUTLET PIPE.

9000

9000
11. TO PREVENT CONTAMINATION OF UNDERGROUND WATER SOURCE NO
SEPTIC TANK SHALL BE CONSTRUCTED LESS THAN 1.20m ABOVE THE
BED 2 BED 2
WATER TABLE LEVEL.
12. ALL PIPE SIZE ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS

4100

4100
OPTICAL OPTICAL

3800

3800
UNLESS OTHERWISE SPECIFIED.
ROOM ROOM
13. MINIMUM SEWAGE PIPE SIZE SHALL BE AS FOLLOWS:
SOIL PIPE 110mm(4"Ø)
BED 3 BED 3
WASTE PIPE 63mm(2"Ø)
VENT PIPES 63mm(2"Ø)
DOWNSPOUT 63mm(2"Ø)
14. ALL PLUMBING INSTALLATION INCLUDED HEREIN SHALL BE UNDER THE
DIRECT SUPERVISION OF A DULY REGISTERED AND LICENSED MASTER BED 4 BED 4
PLUMBER. LAV
FAUCET

MATERIAL SPECIFICATIONS:

100

100
CO
FAUCET
COLD WATER LINE SHALL BE POLYPROPYLENE RANDOM (PPR) TYPE 3 PIPE, W W
LAV
"WAVIN EKOPLLASTIK" BRAND OR APPROVED EQUAL. 2 D PANTRY 2 D PANTRY
VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000,
1500 2 2

1900

1500

1900
VENTILATION VENTILATION
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.. OPEN AREA FD OPEN AREA
FITTING SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564. W W WC
TOILET
WC
SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000, 1 1

GV
TAP TO EXISTING DOWNFLOW
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL. SANITARY PIPE TAP TO EXISTING MAIN WATERLINE

FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM


D2564.
STORM
DRAINAGE LINES/ 1500 100 1260 100 2500 1500 100 1260 100 2500
DOWNSPOUT SHALL BE POLYVINYL CHLORIDE (PVC) SERIES 1000,
"ATLANTA" BRAND OR APPROVED EQUAL. FITTING SHALL BE 5860 5860
SOLVENT CEMENT JOINT TO ASTM D 2564. 250mmØ & ABOVE
MATERIAL SHALL BE CONCRETE DRAIN PIPE (CDP) TONGUE @
GROOVE, MORTAR JOINTS, REINFORCED FOR 300mmØ & LARGER 1 SANITARY LAYOUT 2 WATERLINE LAYOUT
AHU/FCU LINES

FITTINGS
SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 600 II,
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
P-1 SCALE: 1:60MTS P-1 SCALE: 1:60MTS
CHECK VALVES "GREAT VOLUME"," CRANE", "KITS", OR APPROVED EQUAL.
GATE VALVES "GREAT VOLUME","CRANE", "KITS", OR APPROVED EQUAL.
WATER METER "ARAD", "ASAHI" BRAND OR APPROVED EQUAL. PLUMBING LEGEND:

GATE VALVE STORM DRAIN PIPE


SV SHOWE VALVE CWR COLD WATER RISER
KS KITCHEN SINK VSTR VENT STACK THRU ROOF VENT PIPE
LT LAUNDRY TRAY CO CLEAN OUT
F FAUCET SD SHOWER DRAIN
CHECK VALVE
FD FLOOR DRAIN VP VENT PIPE
HB HOSE BIBB WP WASTE PIPE M WATER METER
WC WATER CLOSET SP SOIL PIPE
LAV LAVATORY MV MAIN VENT CB CATCH BASIN
BT BATH TUB VAC VENT ABOVE CEILING CWL
FB FLOOR BATH FCO FLOOR CLEANOUT COLD WATE LINE
UFV UNDER FLOOR VENT
HRP HORIZONTAL RAINWATER PIPING WASTE PIPE
CP CONDENSATE PIPE
DS COWN SPOUT DOWN SPOUT
RD ROOF DRAIN
SOIL PIPE

IMPORTANT ENGINEER DRY SEAL PROJECT TITLE OWNER REVISIONS SHEET CONTENTS: SHEET NO.

AS SHOWN
DC DESIGN PROPOSED 2-STOREY COMMERCIAL BUILDING UNIT 14
P-01
PRC REG. TIN NO. SIGNATURE AND DATE SIGNED
LOCATION: LOT 249 MAYSAN ROAD VALENZUELA CITY
CHECKED BY DATE
PTR NO. PLACE: