Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Heidolph MR 1000 Magnetic Mixer Manuel

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

MR 1000

MR 3000 / MR 3000 D

Betriebsanleitung
Instruction Manual
Mode d’Emploi
Instrucciones de
Empleo
DEUTSCH D
ENGLISH E

FRANCAISE F

ESPAGNOL ES

2
E
Thank you for purchasing a Heidolph Instruments product. This item has been designed, manufactured
and inspected in compliance with DIN EN ISO 61010 for continuous operation and long life performance.

SUMMARY
SUMMARY...............................................................................................................................................9
STANDARD EQUIPMENT & ACCESSORIES..........................................................................................9
GENERAL INFORMATION ....................................................................................................................10
SAFETY INFORMATION .......................................................................................................................10
SET-UP ..................................................................................................................................................11
OPERATION AND CONTROLS .............................................................................................................11
CLEANING & SERVICING .....................................................................................................................12
UNINSTALL, FORWARD & STORE.......................................................................................................12
DISPOSAL .............................................................................................................................................12
MALFUNCTION & REMEDY ..................................................................................................................12
SPECIFICATIONS .................................................................................................................................13
WARRANTY, LIABILITY & COPYRIGHT ...............................................................................................14
QUESTIONS / REPAIR WORK ..............................................................................................................14
CE-DECLARATION OF CONFORMITY .................................................................................................14

STANDARD EQUIPMENT & ACCESSORIES


Standard Equipment

product quantity P/N P/N


230 V / 50/60 Hz 115 V / 60 Hz
MR 1000 or 1 503-02000-00 503-02000-01
MR 3000 or 1 504-00011-00 504-00011-01
MR 3000 D 1 504-03010-00 504-03010-01
Instruction Manual 1 01-005-002-93 01-005-002-93
power cord (MR 3000, MR 3000 D) 1 14-007-003-81 14-007-003-89

Accessories (optional)

product P/N
magnetic stir bars (3 ea.), cylindrical, PTFE-coated 509-56000-00

9
E
GENERAL INFORMATION
Unpack your item carefully.
Inspect for damage and report such damage or missing parts to your supplier right away.

Read your Instruction Manual carefully. Take time to save time while working with your item.
Make sure that every user has read and understood the Instruction Manual.

Please store the Instruction Manual in a place easily accessible to every user.

IF ALL ELSE FAILS, READ THESE INSTRUCTIONS !

A so-called EURO-plug (DIN 49441 CEE 7/VII 10/ 16 A 250 V) is standard on MR 3000 and MR
3000 D appliances. For the Continental US they feature a US-standard plug (NEMA
Pub.No.WDI.1961 ASA C 73.1 . 1961 page 8 15A 125V).
MR 1000 models feature a non-detachable power cord without protective ground terminal and
with flat-type connector (EN 50075, type XVI 2.5 A 250 volts), protective class II.

When using the item in a country with deviating outlet / plug systems, we recommend to use
approved adapters or to have an electrician replace the standard plug with one suiting your
needs.

As shipped, the MR 3000 and MR 3000 D models are grounded. When replacing the original
plug, make sure to reconnect this protective ground wire in the new plug !

SAFETY INFORMATION
Please comply with all safety and accident-prevention regulations as in force for labora-
tory work !

Use extra care when working with flammable substances; refer to safety data sheets.

When connecting your item with your local power supply, please make sure your item is
designed for your local voltage; go by data plate on the item.

Turn your power switch OFF whenever the item is not used, or before disconnecting the
plug.

Repair work is restricted to technicians approved by Heidolph Instruments.

Use extra care when working in the vicinity of flammable and explosive substances. Mo-
tors are of non-sparking type, however, the item itself is not explosion proof

Please do not connect your appliance but with a protective-ground outlet.


(not MR 1000, which is designed for protective class II)

Your item requires a solid stand.

10
E
SET-UP
Set-up
Please locate the item on a sturdy horizontal surface. For reasons of safety, keep the area around the
stirrer module clear of other items
1 1
2 1
2

MR 1000 MR 3000 MR 3000 D

Connect the MR 1000 with your outlet Connect the MR 3000 / MR 3000 D with your
outlet
Do the following checks before connecting: Do the following checks before connecting:
- power switch (1) OFF - power switch (1) OFF
(”0”). (”0”; when ON, toggle switch lights GREEN)
- speed control (2) in extreme left position - speed control (2) in extreme left position
(CCW) (CCW).
Connect item’s power cord with your mains. Connect item with mains by plugging the power
cord in the plug connector (4) located in the items
Note: the appliance features protective rear panel and your outlet.
insulation, no protective ground required.
4

OPERATION AND CONTROLS


Stirring action
Place your container with the magnetic stir bar and fluid on the active surface of your magnetic stirrer.
Magnetic stir bars are available from Heidolph Instruments as an optional accessory.

1 3 1
1
2
2
2

MR 1000 MR 3000 MR 3000 D

Prior to turning the power switch (1) ON, rotate speed control (2) to its extreme left position (CCW).
When turning the power switch ON, stirrer is going to start running at the speed so selected.
Set required speed with the rotary speed control (2), go by the front panel scale marks.
The MR 3000 D uses a 4-digit LED speed display (3).

11
E
CLEANING & SERVICING
Cleaning: wipe housing clean with a damp cloth (add some sort of mild liquid soap).

Note
To avoid damage to the surface finish, avoid using chlorine bleach, chlorine-based detergents,
abrasive substances, ammonia, rags or cleaning agents containing metal particles.

The item is maintenance-free. Repair work is limited to technicians authorized or appointed by Heidolph
Instruments. Please call your local Heidolph Instruments Dealer or a Heidolph Instruments Field Repre-
sentative (also refer to page 14).

UNINSTALL, FORWARD & STORE


Uninstall

Turn the item OFF and disconnect mains plug.

Forward & Store

1. We recommend to store the item and its components in its original box, or a similar container that
offers adequate protection against damage in transit. Tape the box securely.
2. Store the item in a dry place.

Caution
Do not jolt or shake the item during transport.

DISPOSAL
For disposal, please comply with your local or national regulations.
Split by metal, plastic, etc.
Packing material to be treated as described above (material split).

MALFUNCTION & REMEDY


MR 1000 / MR 3000 / MR 3000D
1. power switch dim:
– check power supply and power cord
2. won’t stir:
– no magnetic stir bar in container
– speed control knob in extreme left position (CCW)

In case of a malfunction and you cannot repair as described above, contact your authorized Heidolph
Instruments Dealer.

12
E
SPECIFICATIONS
MR 1000

stirrer drive split-pole motor, electronic speed control,


overheat protection
speed range 0 – 2200 rpm
speed control scale marks
supply voltage 230 volts / 50 Hz; 115 volts / 60 Hz (optional)
protective class II (protective insulation)
power dissipation 7 watts
weight 1.2 kg
dimensions (w x d x h) 120 mm x 140 mm x 80 mm
ambient specifications 0 – 50 °C
at 80 % rel. humidity
chemical resistance housing: polyamide; top plate PVDF

MR 3000 / MR 3000 D

stirrer drive condenser motor, electronic speed control, thermal circuit breaker
speed range 0 – 1250 rpm
speed control MR 3000: scale marks
MR 3000 D: digital, 4-digit LED display, green
top plate made of chromium steel (1.4301)
supply voltage 230 volts 50 / 60 Hz; 115 volts / 60 Hz (optional)
protective class I (protective ground terminal)
power dissipation MR 3000: 25 watts
MR 3000 D: 30 watts
weight MR 3000: 2.4 kg
MR 3000 D: 2.6 kg
dimensions (w x d x h) 240 mm x 155 mm x 120 mm
protection class IP 30
ambient specifications 0 – 40 °C
at 80 % rel. Humidity
chemical resistance housing: polyamide-coat, encapsulated,
active surface: 1.4301 (V2A), front panel: polyester

13
E
WARRANTY, LIABILITY & Note
COPYRIGHT You will receive clearance for sending
your defective item to the following ad-
Warranty dress:
Heidolph Instruments warrants that the present
product shall be free from defects in material (ex- Heidolph Instruments GmbH & Co. KG
cept wear parts) and workmanship for 3 years Lab Equipment Sales
from the date shipped off the manufacturer’s Walpersdorfer Str. 12
warehouse. D-91126 Schwabach / Germany
Transit damage is excluded from this warranty. Tel.: +49 – 9122 - 9920-68
Fax: +49 – 9122 - 9920-65
To obtain such warranty service, contact Heidolph E-Mail: sales@heidolph.de
Instruments (phone: +49 – 9122 - 9920-67) or your
local Heidolph Instruments Dealer. If defects in Safety Information
material or workmanship are found, your item will When shipping items for repair that may
be repaired or replaced at no charge. have been contaminated by hazardous
Misuse, abuse, neglect or improper installation are substances, please:
not covered by this warranty promise.. - advise exact substance
Alterations to the present warranty promise need - take adequate protective action to
Heidolph Instruments’ consent in writing. harm our parts receiving and service
personnel
Exclusion Clause - mark the pack IAW Hazardous Mate-
Heidolph Instruments cannot be held liable for rials Act
damage from improper use or misuse. Remedy for
consequential damage is excluded.

Copyright
Copyright in pictures and wording of the present
Instruction Manual is held by Heidolph Instru-
ments.

QUESTIONS / REPAIR WORK


If any aspect of installation, operation or mainte-
nance remains unanswered in the present Manual, CE-DECLARATION OF
please contact us at the following address:
CONFORMITY
For equipment repairs, please call Heidolph In-
struments (phone: +49 – 9122 - 9920-67) or your
local authorized Heidolph Instruments Dealer. We herewith declare that the present product
complies with the following standards and harmo-
nized documents:

EMC-guideline:
EN 61326: 1997 + A1:1998 + A2:2001+ A3 2003
EN 61000-3-2: 2000
EN 61000-3-3: 1995 + 1997 + A1:2001
EN 61326: 1997 + A1:1998 + A2: 2001+ A3 2003
EN 61000-4-3:2002 +A1:2002
EN 61000-4-5:1995 +A1:2001
EN 61000-4-6:1996 +A1:2001
EN 61000-4-8: 1993
EN 61000-4-11:1994 + A1:2001

Low-voltage guideline (73/23/EWG):


EN 61010-1 + EN 61010-2-051

14
01-005-002-93-0 12/2004

Heidolph Instruments GmbH & Co. KG

Technische Änderungen sind ohne vorherige


Ankündigung vorbehalten.
Technical changes reserved. Publication not
mandatory.
Sous réserve de modifications techniques sans
notification préalable.
Nos reservamos el derecho de introducir
modificaciones técnicas sin previo aviso.