HAFFMANS

CO2 RECOVERY UNIT

BE CO2 SELF-SUFFICIENT BENEFITS


CO2 Recovery Unit (CRU) is a robust and reliable CO2 recovery ∙ CO2 self-sufficiency and beyond
solution for a wide variety of brewery needs ranging from ∙ High quality liquid CO2 ≥ 99.998 % v/v, O2 ≤ 5ppm v/v
300,000 to beyond 5,000,000 hl/yr. It is the benchmark CO2 • High recovery efficiency even at low CO2 inlet purity with
recovery plant in the global brewing industry with 25-year-old ≥ 95% v/v
plants still running strongly.
• Robust design for reliable 24/7 operation, uptime ≥ 95%
The CRU-program comes with a range of options from • Flexible, modular setup to meet site’s layout needs
cost-effective conventional CO2 recovery plants to plants • Natural refrigerants CO2 (R744) and NH3 (R717) applied
incorporating the latest technologies. Each CRU plant is an • Early recovery and up to 60 % energy savings with
individual jewel: We listen carefully to your needs and design LiquiVap (optional)
(y)our CRU to your specific requirements. Not much space • Access to CO2 knowhow and technical support
available for a new plant or retrofit: No worries, our engineers
will find a solution for the most restricted space conditions.
The purity of the liquid CO2 end product exceeds general OPTIONS
quality standards for food/beverage/ingredient purposes • Gas boosters
including the latest edition of the ISBT standard.
• Aerosol washers
Recovering your own CO2 lowers your site’s CO2 footprint • LiquiVap – early recovery and energy-saving system
and reduces your VOC emissions to the atmosphere. Both • Liquid CO2 storage tank
contribute to a more sustainable operation. • Ambient air or Glycol heated vaporizer
Worldwide, customer-specific solutions will be installed • Cylinder filling unit
and commissioned by a team of experienced and well- • Road tanker pump
trained service engineers. But the dedication to your CO2 • Quality control equipment
self-sufficiency continues after the commissioning. Through • Installation and commissioning services
comprehensive lifecycle management, our technical support • Original spare parts
and service team ensures that your CRU operates optimally. • After Sales Services

FOOD & BEVERAGE CRU


CO2 RECOVERY UNIT
PROCESS DESCRIPTION WHY HAFFMANS?
Raw foam-free fermentation gas is fed to the plant where We could bore you with the mere facts of being a market leader
it is buffered in a balloon and scrubbed of water-soluble in CO2 recovery with an installed base of 1000+ plants in the
contaminants such as ethanol in the gas washer. A 2-stage brewing and beverage industry. But the answer is very simple:
dry running CO2 compressor unit increases the gas pressure pure dedication! We are your Total CO2 Management Partner. CO2
to 18barg (261psig) removing condensate in the process. The is running through our business veins. Our R&D department is
remainder of the impurities and water are then removed in constantly researching new technologies to improve CO2 quality,
the dual activated carbon filter and drier unit. Regeneration of recovery rates, and efficiency. After all, seeing a superscript 2 in
this unit is automatic utilizing heating elements and dry CO22 CO2 gives us a heart attack. We don’t want you to be dependent of
purge gas. CO2 liquefaction takes place in a refrigerant cooled CO2 suppliers if you can easily recover your own CO2 and be more
condenser, and O2 is removed in the stripper. The purified independent and sustainable. And foremost: we are there for
liquid CO2 end product is transferred to the onsite storage you when your system is up and running: global service hubs and
tank. dedicated technical support -- we troubleshoot whenever you
need us to keep your plant up and running! That’s why Haffmans!
SCOPE OF SUPPLY
1Gas balloon 6 Refrigerant cooled C02 condenser
2Gas washer 7 Refrigerant condenser
3 2-stage CO2 compressor unit 8 Refrigerant compressor
4 Activated carbon filter & drier > Main parts skid mounted and controlled by MCC
5 Stripper-reboiler

1 2 3 4 5 6 7 8

Raw foam free gas


from fermenters
Liquid CO2
for storage

CO2 Recovery BREWERY CO2 CAPACITY REFRIGERANT FOR FOOTPRINT WATER COOLING POWER
Unit (CRU) CAPACITY LIQUID IN TANK CO2 LIQUEFACTION CONSUMPTION CONSUMPTION CONSUMPTION
Metric 0.3 – 5.0+ 285 / 500 / 750 / ≤ 0.9 l/kg 70 kWh cooling 145 kWh/tonne CO2
Mhl/yr 1000 / 1500 / water/tonne CO2
2000 kg/h 155 kWh glycol/
Natural Flexible
tonne CO2
NH3 (R717) and modular set-
CO2 (R744) up to meet
Imperial 630 / 1100 / 1650 / ≤ 0.12 gal/lbs 9 TORh cooling 88 hph/USton CO2
refrigerants sites layout
0.25 - 4.25+ 2200 / 3300 / water/USton CO2
Mbbl/yr 4400 lbs/h 20 TORh glycol/
USton CO2
Estimated values are for budgetary purposes only, based on:
Inlet CO2 >99.7%v/v, 15 °C (59 °F) @ 150-250 mm (6-10””) WC, foam free gas @ max capacity | Site ambient< 30 °C (86 °F), altitude < 100 m (328 ft), water < 20 °C (68 °F), glycol < -5 °C (23 °F)

LEARN MORE
Interested in an inquiry or more information:
Click or scan our QR code to contact us
or visit us at FOODANDBEVERAGE.PENTAIR.COM

Pentair SGS Sites:


DAYTONA BEACH VENLO FREDERICIA
2361 MASON AVE MARINUS DAMMEWEG 30 SNAREMOSEVEJ 27
DAYTONA BEACH, FL 32117, USA 5928 PW, VENLO, THE NETHERLANDS 7000 FREDERICIA, DENMARK
All Pentair trademarks and logos are owned by Pentair. All other brand or product names are trademarks or registered marks of their respective owners. B  ecause we are
continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.
haffmans_CRU_leaflet_2048_en © 2020 All Rights Reserved.

You might also like