Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

12V 150ah (10hr) : Battery Construction

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

6FM150X 12V 150Ah(10hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid

General Features Performance Characteristics


● Absorbent Glass Mat (AGM) technology Nominal Voltage 12V
for efficient gas recombination of up to Number of cell 6
99% and freedom from electrolyte
Design Life 10 years
maintenance or water adding.
o
Nominal Capacity 77 F(25 C)o
● Not restricted for air transport-complies
with IATA/ICAO Special Provision A67. 10 hour rate (15.0A, 10.8V) 150Ah
● UL-recognized component. 5 hour rate (26.5A, 10.5V) 132.5Ah
● Can be mounted in any orientation. 1 hour rate (102A, 9.6V) 102Ah
● Computer designed lead, calcium tin alloy Internal Resistance
grid for high power density. Fully Charged battery 77oF(25oC) 3.5mOhms
● Long service life, float or cyclic Self-Discharge
applications. 3% of capacity declined per month at 20oC(average)
● Maintenance-free operation.
Operating Temperature Range
● Low self discharge.
Discharge -20~60oC
Charge -10~60oC
Dimensions and Weight Storage -20~60oC
Max. Discharge Current 77oF(25oC) 1000A(5s)
Length(mm / inch) 482±2 / 18.98±2
Width(mm / inch) 170±1 / 6.69±1 Short Circuit Current 2800A
Height(mm / inch) 242±2 / 9.53±2 Charge Methods: Constant Voltage Charge 77oF(25oC)
Total Height(mm / inch) 242±2 / 9.53±2 Cycle use 14.4-14.7V
Approx. Weight(Kg / lbs) 47 / 103.6 Maximum charging current 45A
Temperature compensation -30mV/oC
Standby use 13.6-13.8V
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
5min 10min 15min 30min 1h 3h 5h 10h 20h
Volts/Cell
1.60V 450 351 285 165 102 41.2 28.0 15.9 8.20
1.65V 419 330 270 160 100 40.3 27.6 15.7 8.14
1.70V 388 309 256 155 98 39.5 27.1 15.5 8.08
1.75V 356 289 242 149 95 38.6 26.5 15.3 8.00
1.80V 320 266 228 146 92 37.5 26.0 15.0 7.88

Discharge Constant Power (Watts at 77oF25oC)


End Point
5min 10min 15min 30min 45min 1h 2h 3h 5h
Volts/Cell
1.60V 765 609 501 325 221 201 112 78.0 53.5
1.65V 734 579 483 315 216 198 110 77.1 53.2
1.70V 686 548 465 306 211 195 108 76.2 52.8
1.75V 638 519 446 296 206 190 106 75.3 52.5
1.80V 591 487 425 286 202 184 105 74.0 52.0
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

page1 of 2 www.vision-batt.com
6FM150X 12V 150Ah

Charged
Discharge characteristic (25 C)

Current

Voltage
Volume
Constant voltage charging
o
characteristic (0.25CA,25 C)
(%) (XCA) (V)
12.0 140
Battery voltage(V)

120 0.25
15.0 CHARGED VOLUME
100 0.20
15.0A 14.0 CHARGE VOLTAGE
39.5A 26.5A 80
9.6 0.15
13.0
315A 135A102A 60
0.10
40 12.0

0 20 0.05
1 2 3 5 10 20 30 60 2 3 5 10 20 11.0 CHARGING CURRENT
min h 0 0
0 2 4 6 8 10 12 14 16 18 20
Discharge time Charging time (hours)

Relationship between Self-discharge characteristic


charging voltage and temperature
110
(V/12V)

(V/CELL)
(V/6V)
(V/8V)

(V/4V)

100

90

Capacity(%)
15.6 10.4 7.8 5.2 2.6
80
15.0 10.0 7.5 5.0 2.5

9.6
70
14.4 7.2 4.8 2.4

13.8 9.2 6.9 4.6 2.3 60

13.2 8.8 6.6 4.4 2.2 50

-10 0 10 20 30 40 50 60
40
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months

Cycle service life in relation to


Life characteristics of Standby use
120 depth of discharge
120

100
100
Capacity(%)
Capacity(%)

80
80

60 60 30% Depth of discharge

40 40

20 20

0 200 400 600 800 1000 1200 1400


0 4 6 8
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


15
120

100
Life(years)

10
Capacity (%)

80

60
5

40

20

0 0
10 20 30 40 50
o
-20 -10 0 10 20 30 40 50( C)
o
Temperature( C)

THE INTERNATIONAL CERTIFICATION NETWORK

MH25860 G4M19906-9202-E-16
ISO9001:2000

Shenzhen Center Power Tech. Co., Ltd. www.vision-batt.com


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9)

Page 2 of 2