DA216513 002生水、消防水箱供水管路系统

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SAUDIARAMCO.

NOTES:

1. FOR GENERAL NOTES AND TEST VALUE SEE DWG.

NO. DA-216513.001.

OF
CONSENT
6" 6"

TTEN
(NOTE-5) (NOTE-5)
N8 N8

WRI
24" MW 24" MW
(2 NOS.) (2 NOS.)

M-2A/B M-2A/B

THE
K08-D-0807A K08-D-0807B

THOUT
(NOTES-1&2) (NOTES-1&2)

#4 #4

WI
LEGEND
N6 10"
10" N6
N1 N1

NG
CSO CSO #X

DRAWI
TEST LIMIT
#1 #1

10"-FW-1088-1LE0U

10"-FW-1089-1LE0U
100 RW HHLL 100
N5 RW HHLL
N5

TY
000

TY
000
GAL

USE
500

LI
RW LLL

GAL

USE
500

LI
RW LLL

S
6" 6"

THI
N7

10,

UTI
N7

250

10,

UTI

250
RW LLLL RW LLLL
CSO CSO

500

500

FROM
4"-W-1126-1LE0U #2 #2

RESERVE

RESERVE
GALLON)

GALLON)

NED
FLOW

4000

4000
FLOW

OBTAI
4"-FW-1090-1LE0U

4"-FW-1091-1LE0U
REWATER

REWATER
000

000
OVER

OVER
MW 24" MW 24"

90,

90,
(2 NOS.) (2 NOS.)

BE
#3 #3

(
M-1A/B

FI

FI
M-1A/B

PART,SHALL
N2 12" N2 12"

AT
CSO CSO
GRADE

600

600
4" LEVEL 4"
N4
N4

N
FLOOR FLOOR

I
DRAIN DRAIN

FULL,OR
6"-RW-1106-1LE0U
PI

0509

10"-FW-1086-1LE0U

6"-RW-1107-1LE0U
"
0-XX PSIG

N
I ON
0-XX PSIG

REPRODUCTI
PI REFERENCE DRAWINGS
DRAWING CONTROL FOR J.O. 10-01810-0007 DD-214959
0510

12"-FW-1070-1LE0U

10"-FW-1087-1LE0U
PIPING & INSTRUMENT DIAGRAM DA-216315.001
FROM POTABLE TO FIREWATER
4" CSO
WATER LOADING PUMPS " RAW/JOCKEY
4"
4"-W-1125-1LE0U 4"-W-1127-1LE0U PUMPS
DA-216513.006
K08-G-0713A
CSO K08-G-0713B

SAUDIARAMCO.NO
DA-216513.003

12"-FW-1069-1LE0U
RETURN FROM
FIREWATER PUMPS

DA-216513.003

OF
PROPERTY
SOLE
THE
DA-216513.003

ARE
TO FIREWATER
PUMPS
K08-G-0711

N
HEREI
K08-G-0712

NED
SCALE: NONE

CONTAI
K08-D-0807A/B
REVISION VALIDATION

FIREWATER/RAW WATER TANK THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
(NOTE-1&2)

ON
10-01810-0007-038
TYPE : CONE ROOF

NFORMATI
WORKING VOLUME : 100,000 GALLONS
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
FIRE WATER : 90,000 GALLONS (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)

UTILITY WATER : 10,000 GALLONS ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

PVP DHH SHN EMM


SIZE : 10.5M (DIA) x7.2M (H) 12/14/15 01/24/16 01/24/16 01/24/16

DESIGN PRESSURE : ATM REV.NO. DATE REVISION DESCRIPTION

I
DESIGN TEMPERATURE : 145 F 00 01/24/16 ISSUED FOR CONSTRUCTION

MATERIAL : CS, INTERNALLY LINED

THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-01810-0007 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY

AND
DRAWING TYPE

HYDROSTATIC TEST DIAGRAM HYD

NG
FW/RW TANKS

DRAWI
EAST/WEST PIPELINE PUMP STATION #5

YANBU SAUDI ARABIA

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
K08 A DA-216513 002 00
Saudi Aramco 2615 ENG. (05/05)

RESTRICTED VECTOR CADD-05