Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Fencing Struct 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TOP LVL.

1000
SEE CONSTRUCTION NOTES
FOR MASONRY WALL REIN-
Ø10mm TIES @ 200mm O.C. FIN. FLR. LVL. FORCEMENTS (TYPICAL)
200
5-Ø16mm REBAR
300mmx150mm R.C. BEAMS BOTH WAYS
3000

1000

400
1000
DOWEL BARS TO MATCH
CHB VERTICAL BARS
Ø10mm BOT. BARS
6-Ø12mm MAIN COLUMN NAT. GR. LVL. @300 O.C.
REBARS 4-Ø12mm BOT. BARS
FIN. FLR. LVL.
3 FOOTING DETAILS

200
S-2 SCALE: NTS.

3-Ø10mm TIES @ 100mm O.C


1000

4-Ø10mm TIES @ 50mm O.C.

NAT. GR. LVL. 5-Ø16mm FOOTING MAIN BAR 2 WALL FOOTING DETAILS
S-2
500

SCALE: NTS.
200

200 150

1 COLUMN DETAILS
S-2 SCALE: NTS.

300
400
COLUMN BEAM
SIZE: 200mm x 400mm SIZE: 150mm x 300mm
REBARS: 6 - 12mmØ REBARS: 6 - 12mmØ
TIES: 4 -10mmØ @ 50mm TIES: 4 -10mmØ @ 50mm
3 -10mmØ @ 100mm 3 -10mmØ @ 100mm
2 - JOINT TIES AT 2 - JOINT TIES AT
BEAM INTERSECTION COLUMN INTERSECTION
@ 150mm @ 150mm
SQUARE
1000 1000 200 500 5 - 16mmØ 5 - 16mmØ
FOOTING Rest @ 200mm Rest @ 200mm

F-2 1000 1000 200 500 5 - 16mmØ 5 - 16mmØ 5 COLUMN AND BEAM SCHEULE
S-2 SCALE: NTS
4 FOOTING SCHEDULE
S-2 SCALE: NTS.

REG NO. PROJECT NAME: SHEET CONTENTS: DRAFTED BY: SHEET NO.
TIN NO. PROPOSED PERIMETER FENCE
ENGR. RALPH CHRISTIAN C. GERONIMO COLUMN, BEAM AND FOOTING DETAILS 3
PTR NO. LOCATION: COLUMN AND FOOTING SCHEDULE DATE DRAFTED:
ARCHITECT / CIVIL ENGINEER ISSUED ON: LOT 1 BLK 2 BEDFORD STREET BROOKSIDE HILLS S 2
ISSUED AT: SUBDI. BARANGAY SAN ISIDRO, CAINTA, RIZAL