Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

S301 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

.

HOLD STOOP SLAB CONC SLAB OVER 1 1/2", 20 GA


EDGE BACK 2" WHERE GALV FORM DECK W/ #4 EW @
DWL W/ STANDARD HOOK
EXTERIOR SLAB 1'-0" OC W/ 3" BRG @ EA END
TO MATCH SIZE &
EXTENDS BEYOND
PREMOLDED FILLER SPACING OF HORIZ REINF
STOOP
CONC SLAB

2" CLR

2" CLR
(TYP)
SEE DETAILS FOR

(TYP)
1 1/2"
SLOPE 1/4"/FT SEE PLAN WALL THICKNESS &
T.O. SLAB REINF
SEE CIVIL FOR

5 1/2"
.
STOOP CONN EL= SEE PLAN
3" VOID

4 1/2"
9"
#4 DWL @

1'-3"
1'-4" OC, TYP

LAP SPLICE

LAP SPLICE
SEE SCHED

SEE SCHED
#4 @ 1'-0" OC, EW
SEE PLAN • 2"x4"x6" LONG VERT
8" WALL SEE PLAN FOR WALL • 2"x4"x6" LONG VERT
SIZE & REINF KEYWAY @SPACING OF 1108 S. Main St. 102
RIGID INSULATION HORIZ REINF - SPACE Aberdeen, SD 57401
DWL TO MATCH KEYWAY BETWEEN Phone: 605-725-4852
SEE ARCH
@ EA VERT HORIZ REINF
2 -#5'S @ EA LAYER OF SEE PLAN & SCHED FOR SEE SEE
REINF (TYP @ PERIMETER) FTG SIZE, REINF & EL PLAN PLAN 601 Kansas City St. 7
2 - #5 CONT

1'-0"
Rapid City, SD 57701
NOTE: Phone: 605-716-3652
1'-8" • CONSTRUCTION JOINT SHOWN MAY BE OMITTED @CONTRACTOR'S OPTION.
PIPE 440 E. 8th St. 221

2" CLR
OPENING

TYP
Sioux Falls, SD 57103
8 DOOR STOOP 4 WALL INTERSECTION REINFORCEMENT Phone: 605-334-9999
S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0"
co-oparch.com

3" OC
TYP
11 3"
/2 (TY OC
(T " C P)
Y P LR 3 - #4 VERT W/ #4 DWL CORNER BARS TO CORNER BARS TO
) BARS @ FTG - CORNER MATCH SIZE & SPACING MATCH SIZE & SPACING
2 -#5'S @ EA LAYER OF
REINF (TYP @ PERIMETER) BARS TO MATCH SIZE OF HORIZ WALL REINF OF HORIZ WALL REINF
1'-6"
TYP

1 1/2" CLR
& SPACING OF HORIZ
LAP BAR W/ HORIZ LAP BAR W/ HORIZ

(TYP)
436 E 8th Street
WALL REINF Sioux Falls, SD 57103
(P)605.370.6139
1 1/2" CLR WALL REINF WALL REINF www.heyerengineering.com
140.0002.2023
1/4 SLAB DEPTH 3/16" WIDE SAW CUT
(TYP)

FLOOR/WALL

SEE SCHEDULE
OPENING

LAP SPLICE

LAP SPLICE
SEE SCHED

LAP SPLICE
SEE SCHED
SLAB ON GRADE
TYP WALL TYP WALL
NOTE:
REINF SEE REINF SEE IF THIS SURFACE IS
1 1/2" CLR

1. SAW CUT SHALL BE EXECUTED AS SOON AS


3" OC

DETAILS DETAILS SOIL LOADED


TYP

CONCRETE HAS HARDENED SUFFICIENTLY TO


TYP

SURFACE - EXTEND
PREVENT AGGREGATE DISLODGING BY SAW
#4 VERT W/ HORIZ BARS TO OPP
& PRIOR TO SHRINKAGE STRESS CRACKING.
SEE SEE #4 DWL @ FTG SEE FACE & PROVIDE
2 - #5's X 3'-0" @ EA LAYER OF REINF 2. SEE GENERAL NOTES FOR SPACING
STANDARD HOOK
(TYP @ CORNERS) REQUIREMENTS. PLAN PLAN PLAN

10 ADDITIONAL REINFORCING @ OPENING 7 FLOOR CONTROL JOINT REINFORCEMENT - (CJ) 3 CORNER BAR REINFORCEMENT
S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0"

CO-OP PROJECT NO: 2327

SLAB ON GRADE SAW CUT OR TOOL JOINT IN


SEE PLAN - PLUS EXPOSED SLAB - FILL W/
4" @ JOINT 3/4" POURABLE SEALANT

CONTROL OR

.
GRID CONSTRUCTION JOINT
AS NOTED ON
4" 4" DIAMOND DWL SYSTEM
DRAWINGS
KEY JOINT FORM
07/26/2024
2" BAS
TO

AROUND COLUMN SLAB ON GRADE SAW CUT OR TOOL JOINT IN


(M E

SEE FTG & FDN


IN P L

DURING CONSTRUCTION SEE PLAN - PLUS EXPOSED SLAB - FILL W/

.
)

PLAN FOR SIZE SEE PLANS &


OF SLAB ON GRADE 4" @ JOINT 3/4" POURABLE SEALANT
CONCRETE SLAB DETAILS FOR REINF
(THIS APPLIES TO ALL
ON GRADE
INTERIOR COLUMNS)

.
CONTROL OR EXTEND ALL BARS,
GRID CONSTRUCTION LAP & TIE ISSUE:
JOINT AS NOTED 4" 4"
ON DRAWINGS STOP SLAB REINF @ JOINT 3/4" DIA X 1'-6" SMOOTH ROD 7-26-24 PHASE 1 - CD 100%
@ 1'-0" OC - GREASE ONE END
CONTROL OR INTERIOR COLUMN (6" EMBED GREASED END) REVISION SCHEDULE:
CONSTRUCTION 3"CLR, TYP
JOINT AS NOTED REV. # REV. DSC. REV. DATE
BASE PL
ON DRAWINGS
6 FLOOR CONSTRUCTION JOINT REINF - (CCJ) 2 FOOTING CORNER REINFORCEMENT
DETAIL "A" S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0"
*INCREASE 6" DIMENSION
AS REQUIRED FOR FORMS-
NOT TO INTERFERE W/
COLUMN BASE PL
CONTROL OR VERT CAULK JOINT @ EXPOSED SURFACES OF WALL
(*)

CONSTRUCTION INTERIOR COLUMN 1" STEPPED FOOTING NOTES:


• 2" X 6" X 6" LONG PROJECT:
N

JOINT AS NOTED VERT CAULK • 2" X 4" X 6" LONG


MI

VERT KEYWAY @ 1 1/2" CLR


6"

ON DRAWINGS VERT KEYWAY @ 1. SEE PLAN FOR FOOTING SIZE AND REINFORCING
KEY JOINT FORM SPACING OF HORIZ SPACING OF HORIZ 2. SLOPED OR STEPPED FOOTINGS SHALL BE CAST AS A UNIT
Dacotah Bank Headquarters
AROUND COLUMN REINF SPACE VERT
DURING CONSTRUCTION KEYWAY BETWEEN ROD REINF SPACE KEYWAY 3. STEPPED FOOTING LINES SHOWN ON PLAN ARE @ BOTTOM OF PHASE 1
OF SLAB ON GRADE HORIZ REINF STOCK BETWEEN HORIZ FOOTING 318/320 S. MAIN STREET
REINF
GRID (THIS APPLIES TO ALL • KEYWAY TO BE ABERDEEN, SOUTH DAKOTA
• KEYWAY TO BE CONT 2a (UON) LAP SPLICE
INTERIOR COLUMNS) CONT WHERE PVC WHERE PVC
WATERSTOP IS WATERSTOP IS REQD SEE SCHED
REQD

PLAN
CONTROL OR

SEE
PLAN
SEE

CONCRETE SLAB CONSTRUCTION JOINT AS SHEET TITLE:

a
ON GRADE NOTED ON DRAWINGS
LAP SPLICE
3" LAP SPLICE 3"CLR
FOUNDATION DETAILS
SEE SCHED
TYP
SEE SCHED

a
DETAIL "B" TYP SPA 6" 6" TYP SPA TYP SPA 6" 6" TYP SPA
NOTE:
3" CLR
SLOPE BOTTOM

PLAN
MAXIMUM SPA=40'-0" * MAXIMUM SPA=40'-0" * TYP

SEE
1. USE DETAIL 'A' IF SLAB ON GRADE IS POURED PRIOR TO STEEL ERECTION OF FTGS IN SOIL
2. USE DETAIL 'B' IF SLAB ON GRADE IS POURED AFTER TO STEEL ERECTION WILL NOT STAND
NOTES:

S301.1
7/26/2024 11:27:19 AM

VERT
EQUAL TO FTG
* DIMENSIONS MAY BE INCREASED TO 120'-0" IF WALL IS BACKFILLED ON BOTH SIDES FOR FULL HEIGHT. DEPTH (1'-0" MIN)
* DIMENSIONS MAY BE INCREASED TO 80'-0" IF INTERIOR SURFACE IS NOT EXPOSED. 2a (UON)

9 INTERIOR COLUMN ISOLATION JOINT 5 WALL CONSTRUCTION JOINT - (WCJ) 1 STEPPED FOOTING REINFORCEMENT
S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0" S301.1 1/2" = 1'-0"