S.no Item in scope of work Specification considered for quotation Make and basic price
Structure
Electrical
Nos. As per the sheet attached.
Point wiring shall include all work necessary to complete wiring
from a switch to point outlet of any length, from the tapping
point on the distribution circuit to the switch. The following
Wires - Havells
shall be deemed to have been included in the point wiring: a.
Switches / Sockets -
Ceiling rose or connector as required. b. Any special or suitable
Anchor Roma Classic (
round block, of hylem sheet for neatly housing the connector
white color - Basic cost
and covering the fan hook in case of fan point. c. Conduit bushes
Rs.22/switch )
or sleeves where cable passes through walls etc. d. Earth wire
34 Electrical points MCB - Havells
from three pin socket outlet point / fan regulator to common
DB - Havells
earth. e. Bakelite/hylem/M.S. cover for all pull boxes/ junction
Electrical conduit -
boxes etc as approved by the Engineer in charge. f. All fixing
Anchor
accessories such as clips, rails screw, phil plugs, rawl plugs,
Modular metal boxes -
wooden plugs etc. as required. g. Connection to ceiling rose ,
Anchor
connector socket outlet , lamp holder switch and fan regulator
etc. h. Looping the live wire from switch board and inter
connections between points on the same circuit. i. Circuit wiring.
j. Requisite MCBs
As per electrical points
Anchor Roma classic or
Neutral conductor and earth continuity wire shall be brought to
equivalent
each switchboard
White color switches,
35 Switches & Sockets An earth wire shall be provided along with the circuit wires and
switch plates and sockets
shall be connected to earthing screws inside the box. The earth
are considered in this
terminal of the socket shall be connected to the earth terminal
package
provided inside the box.
All conduits to be concealed inside the wall by cutting chases.
• Minimum dia of electrical conduit should be 20mm
• Minimum thickness of the conduit to be 2mm on slabs/ 1.5mm
on walls.
36 Conduits Anchor
• Separate conduits shall be laid for the following systems: a)
Normal light, Fan and 6 A socket outlets. b) Power points. c) TV
outlets. d) Telephone points / data
- Flexible bends can be provided at additional cost.
Painting
To be painted with 2 coats of water based interior emulsion .
1 Internal Walls JSW Pixa Elegant Interior
Base to be prepared with 2 coats of Putty & 1 coat of Primer
2 Exterior Walls To be painted with one coat of primer and 2 coats of Emulsion. JSW Pixa Elegant Exterior
Mild Steel surfaces ( grills , To be painted with 2 coats of water based satin finish enamel JSW Halo Acquglo
3
handrails, main gate etc ) paint. Majestic Satin
Wooden Door frames to be finished with clear enamel paint
4 Natural Wood
except main door.
Window grills made with 12mm bars @ 4" center to center are
considered in this package ( please refer to the attached
1 Window grills standard schematic design for windows). The weight of grills
considered for this package is 1.25 kg per sft of the grill area.
Grill area is assumed to be equal to 10% of the built up area.
The balusters to be made in 1" x 1" SS square pipe @ 6" center
to center. Hand rail to be in 1 1/2" round SS Pipe. 20 Rft of
2 Staircase Handrails
railing per floor is assumed in the scope of work of this
package. SS 304 Grade
Basic SS Handrail (Basic cost Rs.700/RFT) Considered without
3 Balcony railing
Glass.
Cost of coumpound main gate is not considered in this scope
4 Main Gate and shall be quoted as an additional cost along with cost of
compound wall