Structural Details of Proposed Sump 01 of 03
Structural Details of Proposed Sump 01 of 03
Structural Details of Proposed Sump 01 of 03
600
100
1 DOOR D 1000X2100
C1 C1 C1 C1 C1 2 WINDOW W 1200X1200
3 VENTILATOR V 1200X900
300
W1- 6950 W1-11550 W1- 11550 4 ROLLING SHUTTER RS 3000X2100
200
W1- 7600 300
W2- 7600
W2- 7600
W1- 7600
300 THK 300 THK 300 THK NOTES:
1. ALL DIMENSIONS ARE IN mm AND LEVEL ARE IN m. UNLESS
GRADE SLAB GRADE SLAB GRADE SLAB OTHERWISE SPECIFIED.
2. FIGURED DIMENSIONS ONLY SHALL BE FOLLOWED.
3. R.C.C. DESIGN MIX M-30 CONFORMING TO IS:456-2000 SHALL BE
USED FOR ALL RCC WORKS AND AS PER TECHNICAL
SPECIFICATIONS OF THE CONTRACT.
4. M-15 GRADE OF CONCRETE SHOULD BE USED FOR PCC WORKS
5. CLEAR COVER TO MAIN REINFORCEMENT SHALL BE AS FOLLOWS
* FOR FOOTING = 50mm * FOR BEAMS = 25mm
* FOR COULMN = 40mm * FOR SLAB = 25mm
6. THE SUMP IS DESIGNED FOR EARTHQUAKE LOADING CONFIRMING
TO IS:1893.
7. SAFE BEARING CAPACITY OF SOIL IS CONSIDERED 150kN/m 2 AS
W1- 6950 W1-11550 W1- 11550 PER REPORT FROM THE CONTRACTOR AND THE SAME SHALL BE
ENSURED AT SITE.
8. ALL REINFORCEMENT SHALL BE IN FORM OF HIGH STRENGTH
C1 C1 C1 C1 C1 COLD ROLLED DEFORMED STEEL BARS OF GRADE Fe 550
CONFIRMING TO IS:1786-2008
9. STANDARD 'L' HOOKS SHALL BE PROVIDED AT THE ENDS OF ALL
1200
LAP LENGTH 1.4 TIMES THE DEVELOPMENT LENGTH IN TENSION.
20. IN SHAFT OR WALL NOT MORE THAN ONE THIRD OF VERTICAL
12 @125c/c 12 @150c/c
BARS SHALL BE SPLICED AT ANY SECTION.
1200 21. MANHOLE SHALL BE PROVIDED WITH CAST IRON FITTINGS AT
TOP.
22. SITE TO DECIDE REBAR LAP LOCATIONS AVOIDING ANY LAPPING
IN NO LAPPING ZONE.
ALTERNATE BAR
23. LAPS SHALL BE STAGGERED WITH NOT MORE THAN 50% OF
CURTAILED
BARS LAPPED AT SAME LOCATION.
24. ALL LAPS SHALL BE 1.3 TIMES 'Ld' OF THE HIGHER DIAMETER
200
10 @150c/c 10 @75c/c BAR
300
300
300
WALL-W2 SECTION
WALL-W1 SECTION WALL-W1 SECTION WITH DELIVERY CHAMBER
NTS 01 OF 03