i Ol Master Brochure
i Ol Master Brochure
i Ol Master Brochure
Defining biometry
Trusting the experience
of 100 million
IOL power calculations.
ZEISS IOLMaster 500
// RELIABILITY
MADE BY ZEISS
2
Gold standard biometry with
the ZEISS IOLMaster 500
1) Leaming DV, 2010 Practice Styles and Preferences of U.S. ASCRS Members Survey
2) Haigis W, http://www.augenklinik.uni-wuerzburg.de/ulib/
3
Working with gold standard biometry
The ZEISS IOLMaster 500 highlights
When you work with the ZEISS IOLMaster 500 you not only directly
experience the result of continuous refinement; you also get a piece
of cutting-edge technology that points the way to the future of
optical biometry.
3) Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL, Intraocular lens formula constant optimization
and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgery,
J Cataract Refract Surg. 2011 Jan;37(1):50-62
4) Rivero L, IOLMaster Version 5 vs. Lenstar LS900, presented at 2010 AAO – MEACO Joint Meeting in Chicago, Illinois.
5) Bullimore MA, The IOLMaster and determining toric IOL Power, White Paper, Carl Zeiss Meditec, 2013
6) Chen YA, Hirnschall N, Findl O, Evaluation of 2 new optical biometry devices and comparison
with the current gold standard biometer, J Cataract Refract Surg. 2011 Mar;37(3):513-517
4
5
Improving refractive outcomes
Holladay 2 integrated
The ZEISS IOLMaster 500 has the recognized Holladay 2
formula on board. You can continuously minimize your
prediction error for IOL power calculation. Just enter the
postoperative refraction of your patients – all other data is
automatically fed into the Holladay 2 software calculation.
Telecentric keratometry
Only the ZEISS IOLMaster family features distance-
independent telecentric keratometry. It enables robust
and repeatable measurements due to constant spot center
distances. Thus the ZEISS IOLMaster 500 shows excellent
agreement with manual keratometry while achieving superior
precision performance, making its keratometry the most
trusted among cataract surgeons.7
2) Haigis W, http://www.augenklinik.uni-wuerzburg.de/ulib/
7) Bullimore MA, Buehren T, Bissmann W, Agreement between a partial coherence
interferometer and 2 manual keratometers, J Cataract Refract Surg. 2013 in press
6
Advanced measurement
of challenging eyes
Dense cataracts
In denser cataracts the ZEISS IOLMaster 500 achieves a
measurement success ratio that is up to 20 % higher than
that of other optical biometry devices.4 The underlying
composite signal evaluation not only significantly increases
the fraction of cataracts measurable with optical technology,
but it also greatly increases signal-to-noise values.
Post-LVC eyes
The ZEISS IOLMaster 500 includes the Haigis-L formula which
is dedicated to myopic and hyperopic post-LVC cases and
is very convenient as it requires no clinical history data. 8
Reliable and accurate IOL power The ZEISS IOLMaster 500 simplifies
calculation for post-LVC patients IOL power calculation for patients
with the Haigis-L formula. with prior laser vision correction.
4) Rivero L, IOLMaster Version 5 vs. Lenstar LS900, presented at 2010 AAO – MEACO
Joint Meeting in Chicago, Illinois.
8) Haigis W, Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula.
J Cataract Refract Surg. 2008 Oct;34(10):1658-63.
7
Proven toric outcomes
5) Bullimore MA, The IOLMaster and determining toric IOL Power, White Paper,
Carl Zeiss Meditec, 2013
8
Markerless toric IOL alignment
Reference Image
The Reference Image is the starting point of a
markerless toric IOL workflow: An image of the eye
is taken along with the keratometry measurement.
Both reference image and keratometry data are
transferred to the ZEISS CALLISTO eye ® computer-
assisted cataract surgery system. Finally, all data
needed for precise and markerless toric IOL
alignment is injected in color and high resolution The Reference Image for a markerless toric
where it is needed – in the eyepiece of the surgical IOL workflow.
9
Ease of use
Plausibility checks
With the integrated automatic mode right-eye and left-eye values
for axial length and corneal radii are compared and checked
for plausibility – providing confidence especially for challenging eyes.
Automated workflow
The Dual Mode facilitates measurements of axial length and
keratometry without the need for manual interaction – minimizing
acquisition and chairtime.
Distance independence
The unique distance-independent telecentric keratometry is
one of the reasons for the phenomenal ease of use of the
ZEISS IOLMaster 500. Focusing becomes much easier.
Chairtime
The average time needed to take a reading on the ZEISS IOLMaster 500
is up to 4 times faster compared to other optical devices.6 A difference
you, your team and your patients will notice every day.
6) Chen YA, Hirnschall N, Findl O, Evaluation of 2 new optical biometry devices and comparison
with the current gold standard biometer; J Cataract Refract Surg. 2011 Mar;37(3):513-517
10
Superb connectivity Join the
Cataract Community
Connect to ultrasound
Connect your compatible ultrasound devices directly Get quick and easy access to clinical cases, videos
via Option Sonolink. This ultrasound interface is and more regarding the ZEISS IOLMaster 500.
LAN-based, workflow improved and open for Discover the latest findings in optical biometry, share
various qualified ultrasound manufacturers. your opinion and discuss with peers.
Connect to IT
For integration into electronic medical records
(EMR) and practice management systems, the
ZEISS IOLMaster 500 provides an interface based
on well-known DICOM standards.
Technical data
IOLMaster 500 from ZEISS
Measurement range Axial length 14 – 38 mm Interfaces Ultrasound data link
Anterior chamber depth 1.5 – 6.5 mm ZEISS computer-assisted cataract surgery system
CALLISTO eye (via USB)
White-to-white 8 – 16 mm Data interface for electronic medical record (EMR) /
patient management systems (PMS)
Display scaling Axial length 0.01 mm
Data export to USB storage media
Corneal radii 0.01 mm
Export database for Holladay IOL Consultant and
Anterior chamber depth 0.01 mm HIC.SOAP Pro
Ethernet port for network connection and
White-to-white 0.1 mm network printer
IOL calculation Haigis, Hoffer® Q, Holladay 1 and 2, SRK® II, SRK® / T Line voltage 100 – 240 V ± 10 % (self sensing)
formulas
Clinical history and contact lens fitting method for Line frequency 50 – 60 Hz
calculation of corneal refractive power following
refractive corneal surgery Performance
max. 75 VA
consumption
Haigis-L IOL calculation for eyes following
myopic / hyperopic LASIK / PRK / LASEK surgery Laser class 1
Calculation of phakic anterior and posterior
chamber implants
Optimization of IOL constants
11
0297
Germany
07745 Jena
Carl Zeiss Meditec AG
www.zeiss.com/iolmaster
Goeschwitzer Strasse 51–52
EN_32_010_0022II Printed in Germany CZ-VI/2016
The contents of the brochure may differ from the current status of approval of the product in your country. Please contact our regional
representative for more information. Subject to change in design and scope of delivery and as a result of ongoing technical development.
IOLMaster, FORUM and CALLISTO eye are either trademarks or registered trademarks of Carl Zeiss Meditec AG.
© Carl Zeiss Meditec AG, 2016. All copyrights reserved.