3part led
3part led
3part led
DataSheet
Page 44 of 171
info@gtek.com.sa www.gtek.com.sa
SU-SL03 Street Light ®
Datasheet
SU-SL03 Street Light, a versatile and powerful outdoor luminaire for street lighting applications. This highly efficient
product family provides Smart City compatibility and elegant identity for modern cities, with lower total cost of ownership
and quick payback on investment. With high efficacy, high reliability, low maintenance and excellent optic performance, it
brings safety and well-being for various road illuminations. SU-SL03 Street Light is an ideal solution for residential paths,
collection roads and multi-lane highways.
1 of 4
SU-SL03® Street Light
Technical Data
Optical Specifications
System Specifications
Power AC line
DIMENSIONS ( mm)
100W 510*315*70
150W 590*315*70
200W 660*315*70
250W 745*315*70
300W 830*315*70
Due to the special conditions of manufacturing process of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual pa-
rameters of each single product which could differ from typical data.
Exceedingmaximumratingsforoperationvoltagewillcause hazardousoverload and will likely destroy the LED module.
Page 46 of 171
2 of 4
SU-SL03® Street Light
Dimensions
450mm
600mm
520mm
250W 300W
285mm 285mm
760mm
680mm
Page 47 of 171
3 of 4
SU-SL03® Street Light
Photometrics
Light Distribution Curve
300 500
Page 48 of 171
4 of 4
Charge Controller Datasheet
Page 97 of 171
info@gtek.com.sa www.gtek.com.sa
2. PV wake up:
Intelligent power curve: Specific [Parameter settings] and [operation status] of the remote control are as follows:
1. Overview Charging Voltage Charging Voltage A. If [Yes] is selected for the [PV wakeup] function, after the controller enters sleep mode, the PV
A B C panel connected can wake it up and conduct charging during the day with good conditions for Load power/W Parameter settings:
Float Charging A B
The DM series waterproof all-in-one constant current MPPT charge controller integrates MPPT Equalizing charge voltage
Bulk Charging Constant Charging
Bulk Charging Constant Charging
charging. If charging time is more than 1 minutes, the load will be automatically turned on at 30
Boost
night; if charging time is less than 1 minutes, the loads will not be turned on at night and the Items Default Range
solar charge management, LED step-up constant current drive, IoT remote communication and Boost charge voltage Charge voltage
25
lk
controller will continue to sleep;
Bu
Floating charge voltage
other functions. Ideal for lead-acid battery / lithiumbattery / colloidal battery, it is widely used Charge return voltage B. If [No] is selected for the [PV wakeup] function, after the controller enters sleep mode, the PV 20 Battery type Lead Lead / lithium 12V / lithium 24V
for solar street lights, solar garden lights,etc.,providing high reliability, high efficiency, high panel connected can wake it up and conduct charging during the day with good conditions for 15 #1-Load power Sensing delay No No
charging, while the controller will continue to enter sleep mode at night.
precision, ease of installationand maintenance and other benefits. #2-Time
PV wake up No/Yes
Time Time
(Note: [PV Wakeup] function can be selected by CU remote control). 10 Yes
#3-High
22:23:20
23:07:50
23:52:20
0:36:50
1:21:20
2:05:50
2:50:20
3:34:50
4:19:20
5:03:50
5:48:20
6:32:50
7:17:20
8:01:50
8:46:20
9:30:50
10:15:20
11:00:20
11:44:50
12:29:20
13:13:50
13:58:20
14:42:50
15:27:20
Range:10~600min) indicators after sleep
Wakeup mode
and faster speed Cumulative time:3h
Over discharge voltage 11.0V 9.00V-17.0V
◆Both lead-acid battery and lithium battery are applicable, operating parameters Max. current Max. current
CU-ALL5 OFF button ON button -- -- All are off
Over discharge return voltage 12.6V 9.00V-17.0V
Gen4
can be set by remote control; CU-mini2 OFF button ON button -- -- All are off
◆Using UltraGreen power control technology with extremely low power consumption and Intelligent power test data Boost charge 14.4V 9.00V-17.0V
Automatically lights up for
sleep current PV charging for
Can charge 10 seconds after wake-up.
Floating charge 13.8V 9.00V-17.0V
PV wake up [Yes] -- normally Test whether the load is --
◆ Lead-acid battery multi-stage constant voltage charging with temperature compensation; Time Time
10 seconds during the day normal. It can discharge Comparison between intelligent power consumption and that in rainy days
Low temperature charge -35℃ -35℃-0℃
◆10-period programmable load power/time control; normally at night.
DM Series
Lead-acid battery charging stages curve graph Lithium battery charging stages curve Intelligent power levels Power consumption per day Sustainable operating days
◆Battery charge and discharge high and low temperature protection, with operating Automatically lights up for High temperature charge 65℃ 40℃-90℃
10 seconds after wake-up.
temperature settable; Can charge
Test whether the load is No 100% 1 0.33A 0.15A-7.0A
PV wake up [No] -- PV charging normally -- Load current
◆A variety of intelligent power modes are available for choice, with load power adjustable Bulk Charging for 10 seconds during the day normal. It does not
discharge at night and Low 50% 2 Intelligent power Moderate No/High/Moderate/Low/Auto/*USE
automatically according to the battery level; In bulk charge stage, the battery voltage has not yet reached the set value of full charge continues to sleep.
◆High precision digital step-up constant current control algorithm, ensuring high voltage (i.e. equalizing/boost charge voltage) and the controller will perform MPPT Medium 25% 4 *Derating start voltage 12.4V 9.00V-17.0V
efficiency and high constant current accuracy; charging, which will provide maximum solar energy to charge the battery. When the 2.3 Indicator and remote control status:
User Manual
High 15% 6 *Derating end voltage 11.4V 9.00V-17.0V
◆Infrared wireless communication, allowing for setting/reading parameters, reading status, etc; battery voltage reaches the pre-set value, charge at constant voltage will start. The DM series controllers have three red indicators
◆Multiple protections such as battery/PV reverse polarity protection, LED short- Three red indicators: ]Test description: 1. The test battery is fully charged, the maximum load power is consistent, *Minimum current 0.15A 0.05A-1.00A
Constant Charging and the operating time is consistent.2. Aoff.ssume that the power consumption is 100% when
circuit/open-circuit/limited power protection, etc; Nth time 00:00-15:00
◆Extensible to IoT remote communication monitoring function; When the battery voltage reaches the set value of constant voltage, the controller will Remote control the intelligent power is turned
Indicator Status Description system status 3. The test result is the data obtained under a single condition (the charge level is 0 per day). Power with no human
◆Full aluminum housing, IP67 waterproof rating, applicable to a variety of harsh perform constant voltage charging. This process will no longer include MPPT charging, Load parameter settings 0%-100%
and the charging current will gradually decrease with time. Constant charge includes two Steady on Solar panel voltage is higher than light control voltage Idle The actual use may be different from the test conditions, and the test results are for reference motion sensed
environments. only. Power with human
stages, i.e. equalizing charge and boost charge. The two stages are conducted without Off Solar panel voltage is lower than light control voltage Idle 0%-100%
repetition, in which equalizing charge is started once every 30 days. motion sensed
Double flash Fully charged Fully charged Auto - Intelligent power mode automatically selects high/moderate/low level according
2. Instructions for Use Factory reset No No/Yes
Boost charge Slow flash In charging Charging to the parameters such as daily charge and power consumption;
PV indicator for example, in summer, the charge level is large, it runs in low power mode, and the
Description The default duration of boost charge is 2 hours. The customer can also adjust the holding BMS protection
Product models 2.1 MPPT charge introduc
tion: time and the pre-set value of boost voltage point according to actual needs. When the or BAT overvoltage
E-BMS lighting effect is better; in winter, the charge level is small, it runs in high power mode, the Default load parameter settings:
Battery overvoltage
duration reaches the set value, the system will switch to floating charge. or PV overvoltage
load works in the power saving mode and can hold in more rainy days.
All-in-one Constant Current MPPT Charge Controller Common controller working point Quick flash PV panel overvoltage
DM-R/W USE (user-defined)-The user is allowed to set the derating start voltage, the derating end
(-R: infrared remote control; -W: wireless remote control)
or over temperature (ambient temperature) Over temperature Time period Hrs/Min Power in the period
Current Equalizing charge or power/ current limited charging Overcurrent voltage, and the minimum load current value for the intelligent power;
Maximum power point 1 00:30 50%
DM-UL With IoT remote control (built-in Lorawan module) Certain types of battery benefit from regular equalizing charge, which can stir electrolyte, Steady on Battery works properly Idle 2 00:30 70%
balance battery voltage, and complete chemical reaction. Equalizing charge increases the Derating starting point voltage
DM-NB With IoT remote control (built-in NB-Iot module) battery voltage above standard voltage, causing vaporization of battery electrolyte. If it is Battery is not connected or lithium battery Load current (mA)
BAT indicator Off 3 02:00 100%
detected that the controller automatically controls the next stage to be equalizing charge, protection board over discharge protection
DM-GP With IoT remote control (built-in GPRS module) the equalizing charge will last for 120 minutes (default). The equalizing charge and boost Quick flash Battery over-discharge Over discharge 4 00:30 70%
charge are not repeated in a full charge process to avoid too much gas evolution or Derating ending point voltag
battery overheating. Steady on Load is turned on Discharging 5 00:30 50%
DM-BT With Bluetooth remote control(built-in Bluetooth module)
Voltage Off Load is turned off Idle 6 04:00 30%
Floating charge LOAD indicator
(take 12V battery system as an example) Slow flash Load is open circuited Open circuit 7
With IoT remote control (RS485 interface, external Floating charge is conducted following the holding charge stage, where the controller will
DM-C Minimum load current
reduce the battery voltage by reducing charge current and allow the battery voltage to Quick flash Load is short circuited Short circuit
communication module is required) 8
Maximum Power Point Tracking (MPPT for short) is an advanced charging technology. remain at the floating charge set value. During the floating charge stage, the battery is 50mA
charged in a very low voltage to maintain full charge state of the battery. In this stage, the 2.4 Intelligent power: 9 00:00 0%
With IoT remote control (TTL interface, external comm The MPPT controller can detect the generation power of the solar panel in real time and track the
DM-CT load can get nearly all of the solar energy. If the load exceeds the energy that solar panel The DM series controller is available in various intelligent power modes for selection according
-unication module is required) maximum voltage and current value (VI), allowing the system to charge the battery at the maximum can provide, the controller will not be able to maintain the battery voltage in the floating 12.7V 12.0V Pre-dawn
to the actual battery capacity, the number of rainy days and other factors. The specific Battery voltage(V) lighting time
efficiency. Compared with traditional PWM controller, the MPPT controller can maximize the power charge stage. When the battery voltage is as low as the recovery charge set point, the 2.5 Remote control operation:
system will exit floating charge stage and re-enter the fast charge stage. intelligent power modes are: High, Moderate, Low, Auto, USE (user-defined), No (off).
of the solar panel, so that it can provide alarger charging current. Generally, the MPPT controller 2.5.1. Remote control CU/ALL5: Status data:
Intelligent power levels:
can increase the energy utilization by 15% to 20% compared with the PWM controller. 2.2 Sleep and wake up: The communication between the controller and the handheld remote control CU-ALL5 can be Press the [Status] button on the remote control at any interface to read the [Run Status]
High -The battery capacity at the starting point of power derating is high, and the load lighting
data of the controller;
As a stage of charging, MPPT cannot be used alone. It is usually necessary to combine the boast
charge, floating charge, equalizing charge and other charging modes to complete the battery
Enter sleep mode:
Press the [OFF] button on the CU remote control or mini remote control. The controller
time is the longest. It is suitable for use in areas with more rainy days or poor lighting conditions;
Moderate-The battery capacity at the starting point of power derating is moderate, and the load
controlled by infrared remote control or wireless remote control mode. Press [+] and [-] buttons on
the remote control at the same time to select [Remote Control Type] (Infrared/Wireless) for remote
Page 98 of 171
Press and hold the [Status] button on the remote control at any interface to enter the
turns off all external control devices, and enters sleep state with very low power [Status Data] submenu, where you can choose to read [Run Status] / [Historical Data], that
charging process. lighting time is moderate. It is suitable for the scenarios where both brightness and the number operation. In actual use, the i remote control signal is easy to attenuate under outdoor strong light,
consumption to avoid lithium battery feed due to long time no use; is, select [Run Status] or [Historical Data] and press the [Status] button to read the
Version: V1.04 The complete charging process for a lead acid battery includes: Quick charge, holding charge and of rainy days are considered; the remote communication distance is 5-6m, while at night, the remote communication distance is
Wake up from sleep mode: corresponding status data.
Subject to change without notice Low-The battery capacity at the starting point of power derating is low, and the load lighting 8-10m; the wireless remote control signal can penetrate plastic or aluminum housing, and the
floating charge. In sleep mode, press the [ON] button on the CU remote control or mini remote control to
The lithium battery charging process does not include equalizing charge and floating charge. wake up the controller and resume normal operation; time is the shortest. It is suitable for scenarios with high lighting requirements; wireless remote control distance can be adjusted from 0.3mnfrared to 20m via the remote control.
01 Run Status: 2.5.2 Remote control CU-mini2: (optional)
3. Technical parameters 4. Protections 5. Electrical wiring diagrams 6. Common abnormalities and Solutions
The mini type remote control CU-mini2 is used for turning on/off and testing.
Name Example Description
Current run status: discharge / charge / idle / full / over Controller Controller sleep Adjust- ●Water ingress protection A. Wiring diagram of the controller with built-in IoT module No. Exceptions Causes Solutions
System status Discharging Items Values able
Default
discharge, etc. wake-up ON OFF IP rating: IP67
B1. Press the“+”and“-”keys at the same time to
Model DM60 DM80 DM120 DM160 DM200 DM260 DM300 ●Lithium battery BMS overcharge protection Wiring sequence: Firstly connect the load, then the battery and finally the solar panel. A.The remote control password
Battery voltage 12.3V Current voltage of the battery is incorrect
bring up the [Remote Control Settings] interface and
Controller type -R: infrared remote control; -W: 2.4G wireless remote control;-C: with 485 communication interface When the controller detects that the BMS is overcharged, the controller stops charging set the correct password.
B.Remote control mode B2. Press the“+”and“-”keys at the same time to
PV voltage 17.6V Current solar panel voltage +10%
System voltage 12V 12V/24V Lead-acid immediately, preventing the high voltage of the photovoltaic terminal from being applied to
Remote control (infrared or wireless) is not bring up the [Remote Control Settings] interface, and
70% 50% 30%
Load test command Static power -R:≤5mA -R:6mA/12V; 4mA/24V
-R:≤6mA -R:8mA/12V; 12mA/24V
both ends of the BMS for a long time, causing the BMS to be damaged by high voltage. 1 selected correctly then select [Infrared Remote Control] or [Wireless
Charge current 0.0A Current charge current cannot work
-10% consumption -W:≤20mA -W:≤20mA -W:18mA/12V;13mA/24V -W:20mA/12V;16mA/24V ●Lithium battery low temperature charging protection C.Wireless remote control Remote Control].
C1. Press the“+”and“-”keys at the same time to
Charge power 0.0W Current charge power When ambient temperature drops to the set value, the controller stops charging to prevent distance setting is too short
bring up the [Remote Control Settings] interface, and
Sleep power consumption ≤1mA ≤2mA
irreversible damage to the lithium battery due to low temperature charging. D.The remote control battery then increase the [Remote Distance] before testing.
Load current 50~3000mA 50~4200mA 50~5600mA 70~7000mA √ 330mA
Charge AH 0.01AH Charge AH of the day When ambient temperature is higher than the set value, the controller stops charging and is low D1. Please replace 2 AA (No. 5) batteries
Load voltage 15V~50V 15V~40V 15V~60V 15V~75V
Green power is changing our life. discharging to prevent damage to the lithium battery from due to excessive temperature.
Load voltage 27.1V Current load voltage 60W/12V 80W/12V 100W/12V 130W/12V 150W/12V A1.Check if the battery wiring is intact
Maximum load power 60W/12V 80W/12V ●Battery reverse polarity protection A2.Check if there is voltage on the battery terminal
120W/24V 160W/24V 200W/24V 260W/24V 300W/24V There is no response
Load current 1.00A Current load current A total of 7 buttons are available: [ON], [OFF], [70%], [50%], [30%], [+10%], [-10%], As the battery polarity is reversed, the system does not work and will not burn the controller. 260W
17V~72V
520W
34V~72V
2 A.Battery is problematic in and whether the protection board is activated. If
Load conversion efficiency 85%-96% (Typical efficiency 95%) 100V when the controller is
●PV input terminal overvoltage protection there is no voltage on the battery terminal, it
button icons and descriptions are as follows: 20A
connected to battery, power supply
Load power 27.2W Current load power Load current accuracy ≤3%±30mA 100W 200W
the indicator light is off B.Controller goes to sleep indicates that the protection board has provided
When the voltage at the PV panel input terminal is too high, the controller will automatically cut 15V~75V 30V~75V
7
When the polarity of the PV array is reversed, the controller will not be damaged. After light up at night, and the sleep state A2. Select <PV Wakeup> to “Yes”, and the
Ambient temperature
28.5±0.2
23℃ Current internal temperature Maximum charge current 10A 15A 10A 15A 20A 30A 40A
114±0.25
correcting the wiring error, it will continue to work properly. LED indicator on the controller will be activated automatically after
74±0.2
Maximum solar input voltage ≤50V ≤35V ≤60V ≤100V
2 controller does not light up
Running days ●Load power limit protection
80±0.2
66±0.2
15D Accumulated running days MPPT Tracking efficiency >99%
either
When the power of LEDs that the customer uses is too large, or the load current is adjusted to
Number of over Charging conversion eff. 85%-98%(Typical efficiency97% ) be excessive, the controller will limit the load power output to less than the rated power, to The battery indicator flashes A1. Turn“Intelligent power”off and test load current
2N Total number of over discharge of lithium battery Note: The controller with quickly, and the load LED A. Battery is low
2
B1. Set the current to be smaller or replace the lamp
discharge Over voltage PB-16.0V; LI-overcharge voltage +2V; × 2, 24V system 16.0V ensure that the controller and LED load will not be damaged. 4 does not light up
antenna is a IoT type. with fewer LEDs in series.
Limited charge voltage PB-15.5V; LI-overcharge voltage +1V; × 2, 24V system 15.5V ●Load overload and short circuit protection
Number of full charge 10N Total number of full charge of lithium battery 75 82.3 A1. Check if the solar panel is charging normally and if
82±0.35 88.3±0.2 Equalizing charge voltage PB-14.6V; LI-None; ×2,24V system 14.6V When the number of LEDs connected in series in the load is too low (3 strings or less), the the solar panel configuration is correct.
Production date 1810 Production date of controller Equalizing charge interval PB: 30 days;LI: no; 30D controller will stop output immediately to prevent damage to LED load or controller; B. Wiring diagram of the controller with external IoT module A. Battery is low A2. Check if the lithium battery has a single-cell
24.5±0.2
Load lighting time is short protection.
22.6
Boost charge voltage When a short circuit occurs, the controller immediately cuts o the load output to prevent B. Load power is excessive
Wiring sequence: Firstly connect the external IoT module, then the load, then the 5 A3. Enable the “Intelligent power" option
Software version 1000 Software version of controller (lead-acid) 8.5V ~ 17.0V;×2,24V system √ 14.4V damage to the controller. After the load short-circuit condition is released, the controller B1. Check if the controller current setting is correct and
Charge voltage (lithium)
automatically resumes output within 1 minute (if it has been short-circuited for a long time, it battery and finally the solar panel. if the load power is normal.
DM60 dimensions: DM80/DM120 dimensions:
Historical data: Overall dimensions: 80*82*22.6mm Overall dimensions: 114*88.3*24.5mm
Floating charge voltage will automatically resume output once every 1 hour), or press and hold the test button on the A. Load current is regulated A1. Turn “Intelligent power” off and test load
(lead-acid) Load lighting current does in intelligent power mode current
The historical running data of the controller in the last 30 days can be read by the remote controller, Mounting dimensions: 66*75mm Mounting dimensions: 74*82.3mm 8.5V ~ 17.0V;×2,24V system √ 13.8V remote control (CU or mini2) for 10s to automatically resume output.
Charge return voltage 6 not reach the set value B. LED power exceeds the B1. Set the current to be smaller or replace the lamp
and the number of days to read can be selected. Mounting hole diameter: φ3.5mm Mounting hole diameter: φ3.5mm (lithium)
●Load open circuit protection rated value with fewer LEDs in series.
16
φ3.5 Light control voltage 3V ~ 11V;×2,24V system 5V and hold the test button on the remote control (CU or mini2) for 10s to automatically resume replace the light appropriate number of LEDs in
20
11.2V Minimum voltage of the battery in the past N days φ3.5 Light control delay 0s~60s/2min ~ 60min √ series or parallel.
Minimum voltage 10S output. 260W
17V~72V
520W
34V~72V
Maximum voltage 14.2V Maximum voltage of the battery in the past N days Low temperature charge 0℃ ~ -35℃ √ -35℃
100W 200W
8 LED load dimming fails
series is incorrect, 3 LEDs A1.Replace with step-up LEDS (5 or more strings)
At night, the battery is prevented from discharging through the PV panel. 15V~75V 30V~75V
or step-down LEDs are
Operating temperature -35℃ ~ +65℃ used
Maximum ambient temperature in the past N days ●TVS lightning protection.
142±0.25
116
102±0.2
155
IP rating IP67 A.Solar panel is not A1. Check if the battery board is connected correctly and
connected if the wiring is reliable.
Minimum temperature 23℃ Minimum ambient temperature in the past N days 9 Lighting during the day
B.Solar panel polarity is B1. Reverse the solar panel wiring during the day to see if
Battery reverse polarity protection, solar panel reverse polarity protection, 1 2 reversed the charging indicator flashes.
Maximum charge power in the past N days solar panel over-voltage protection, lithium battery overcharge and over- 4
Charge power 205W Protections The charge
discharge protection, lithium battery BMS overcharge detection protection, A.Solar panel failure or A1.Check if the solar panel connection is
indicatordoes not flash
7
7
over temperature protection, load open circuit and short circuit protection, 10 solar panel wiring error
Lighting time 07:10 Lighting time at night in the past N days slowly whenthere is correct and reliable, and if the solar panel is
sunlight during the day. blocked.
82.3 102 Weight 260g 400g 510g 770g 1800g The communication line interfaces
Charge AH 55AH Total charge AH in the past N days 88.3±0.2 114.4 3 A.The solar panel voltage is
Controller dimensions (mm) 80*82*22.6 114*88.3*24.5 142*88.3*24.5 155*114.4*34 200*122.5*56 not lower than the light A1. LED load automatically lights up after the solar
are defined as follows: LED load does not light
Charge AH 49AH Total discharge AH in the past N days Controller mounting up, battery indicator is control voltage or the delay panel voltage drops
24.5±0.2
42
3 45W~34
35
65
5 0W
MONOCRYSTALLINE MODULE
ADVANCED PERFORMANCE & PROVEN ADVANTAGES
SPECIAL WARRANTY
committed to
delivering innovative
energy solution
Page 64 of 171
ELECTRICAL CHARACTERISTICS AT STC
Maximum Power (Pmax) 445W 450W 455W 460W
Open Circuit Voltage (VOC) 41.2V 41.4V 41.6V 41.8V
Short Circuit Current (ISC) 13.75A 13.80A 13.85A 13.90A
Voltage at Maximum Power (Vmp) 34.4V 34.6V 34.8V 35.0V
Current at Maximum Power (Imp) 12.94A 13.01A 13.08A 13.15A
Module Efficiency (%) 20.57 20.80 21.03 21.26
Operating Temperature -40°C to +85°C
Maximum System Voltage 1000V DC/1500V DC
Fire Resistance Rating Type 1(in accordance with UL1703)/Class C(IEC61730)
Maximum Series Fuse Rating 25A
2
STC: lrradiance 1000W/m , Cell temperature 25°C, AM1.5; Tolerance of Pmax: ±3%; Measurement Tolerance: ±3%
1093
Bar code R4
8-9×14 .5
Mounting holes
41
Label
B 9
2- 4 A A
B Current-Voltage and Power-Voltage Curves
Grounding holes
at Different Irradiances
809
8091
8051
4-7.5×7.5 16-3.5×8.5
Drainage holes Drainage holes
35