OSCE- IV Cannulation
Sr Procedure Checklist Yes No Marks
No 1 Ensure that you have all of your equipments ready for iv cannulation. 1 2 Sanitise your hands using alcohol cleanser. 1 3 Identify the vein to be canulated. 1 4 Apply the tourniquet and re-check the vein. 1 5 Put on your gloves, clean area of vein with the alcohol wipe and let it dry. 1 6 Remove the cannula from its packaging and remove the needle cover ensuring not to 1 touch the needle. 7 Insert the needle, bevel upwards at about 30 degrees in the vein. 1 8 Once position of needle confirmed, progress the entire cannula a further 2mm, then 2 fix the needle, advancing the rest of the cannula into the vein. 9 Release the tourniquet, apply pressure to the vein at the tip of the cannula and 1 remove the needle fully. Remove the cap from the needle and put this on the end of the cannula. 10 Carefully dispose of the needle into the sharps bin. 1 11 Apply the dressing to the cannula to fix it in place and ensure that the date sticker 1 has been completed and applied. 12 Check that the use-by date on the saline has not passed. If the date is ok, fill the 2 syringe with saline and flush it through the cannula to check for patency. If there is any resistance, or you notice any localised tissue swelling: immediately stop flushing, remove the cannula and start again.
13 Dispose of your gloves and equipment in the clinical waste bin. 1
Total Marks ( / 15) Materials Required Alcohol cleanser, Gloves, alcohol wipe, disposable tourniquet, IV cannula, suitable plaster, syringe, Saline
OSCE- Intra dermal injection
Sr No Procedure Checklist Yes No Marks 1 Gather all supplies: medication syringe, non-sterile gloves, alcohol swab and 1 sterile gauze, Band-Aid (if required). 2 Prepare medication or solution & Check physician orders. 1 3 Select appropriate site for administration. 1 4 Perform hand hygiene and apply non-sterile gloves. 1 5 Clean the site with an alcohol swab or antiseptic swab. Allow the site to dry. 1 6 Remove needle from cap by pulling it off in a straight motion, ensuring not to 1 touch needle. 7 Hold the syringe in the dominant hand between the thumb and forefinger, with 1 the bevel of the needle up. 8 Keeping the bevel side up allows for smooth piercing of the skin and induction 2 of the medication into the dermis. 9 Once syringe is in place, slowly inject the solution while watching for a small 2 weal or bleb to appear on site of injection. 10 Withdraw the needle at the same angle as insertion, engage safety shield or 2 needle guard, and discard in a sharps container. Do not massage area after injection. 11 Discard remaining supplies, remove gloves, and perform hand hygiene 1 12 Proper documentation helps ensures safety so document time, date, location, 1 and type of medication injected. Total Marks ( / 15)