Draft ROA BTB-02-II-24-SMR-280 ACHMAD FAISAL (EXPRESS)
Draft ROA BTB-02-II-24-SMR-280 ACHMAD FAISAL (EXPRESS)
Draft ROA BTB-02-II-24-SMR-280 ACHMAD FAISAL (EXPRESS)
THIS IS TO REPORT that upon the request of the principal, the sample received were analyzed in the PT. TRIBHAKTI INSPEKTAMA, Samarinda Laboratory (accredited by
KAN / National Accreditation Committee - Indonesia for ISO/IEC 17025:2017 Cert. No. LP-1378-IDN) in accordance with the following standard method. The results are as
stated below :
PARAMETER OF ANALYSIS
WEIGHT TM IM ASH VM FC TS CV
NO SAMPLE CODE
(Kg) (%) (%) (%) (%) (%) (%) (kcal/kg) (kcal/kg) (kcal/kg)
Ar Adb Adb Adb Adb Adb Adb Ar Daf
1 PIT DONDANG 7.52 29.78 14.05 1.32 42.22 41.34 0.88 5,348 4,412 6,430
Note : 1. Ar (As Received Basis), Adb (Air Dried Basis), Daf (Dry Ash Free)
2. STANDARDS : TM = Total Moisture (ASTM D3302/D3302M-22a) FC = Fixed Carbon (ASTM D3172-13 (2021)e1)
IM = Moisture in the Analysis Sample (ASTM D3173-17a) TS = Total Sulphur (ASTM D4239-18e1) (Combustion Method A)
ASH = Ash Content (ASTM D3174-12 (2018)e1) CV = Gross Calorific Value (ASTM D5865/ D5865M – 19)
VM = Volatile Matter (ASTM D3175-20)
This report is prepared and issued by the Company upon request by Principal/Applicant and the analysis contain therein reflects the Company’s findings on the analysis of
sample submitted by the Principal/Applicant and/or drawn by the Company at the time and place of performing the inspection/testing only. The Company shall not be liable
to any legal consequences resulting from any business or transaction using this report.
ROA No : BTB-2402SMR.XXX