preferred choice of producers of rubber parts. That is because LSRs offer better end-product performance, and the injection molding technique offers high levels of automation and almost 24x7 production. LSRs are also ideal for rubber parts in general applications as well as for specific market demands such as food contact. Now, in addition to the wide range of Silastic LSRs from Dow Corning, manufacturers can take advantage of a new liquid silicone rubber product one that can withstand extreme temperatures and highly aggressive solvents and other chemicals: Silastic Fluoro Liquid Silicone Rubber (or Silastic F-LSR for short) is a LSR with the performance characteristics of FSR. This makes it ideal for the automotive and aerospace industries and for other extreme applications. This brochure discusses the basics of injection molding using Silastic LSRs and F-LSRs and what manufacturers need to know to fully exploit the associated timesavings and productivity improvements. For further information on Silastic LSRs and F-LSRs, please contact the Dow Corning Technical Service & Development department via your nearest Dow Corning sales offices.
Dow Corning
2 4 4 4 5 6 7 7 8 9 9 9 10 10 10 10 10 11 12 13 14 15 15 16 16 17 18 18 19 19 19 20 22 24 24 25 25 25 26 27
Viscosity Injection Holding Pressure Material Cushion Pressure in the Cavity Material Supply Mixing Dosing Back Pressure Overmolding Opportunities Vulcanization speeds and Cycle Times Curing Behavior of Silastic LSR Post-Curing
Principles of mold design for SILASTIC LSR
Shrinkage Parting Line Venting Injection Point Demolding and Ejector Systems Mold Materials Cavity Surface Finish Temperature Control
Selection of machine
Two Component Injection Molding Injection Molding of One Component Silastic HCR Rapid Cure
Starting the production
Temperature Preset Injection Stroke and Flow Switchover and Holding Pressure Curing Time Demolding Production End and Clean-Up
Trouble shooting for injection molding of SILASTIC LSR
Dow Corning
Silastic Liquid Silicone Rubber (LSR) was pioneered by Dow Corning and introduced to the rubber fabrication marketplace in the late seventies. More recently, Dow Corning has introduced a new LSR that is fluorinated: Silastic F-LSR. This new rubber is a true LSR but with the performance properties of a FSR. This means it can withstand the extreme temperature conditions and aggressive solvent environments of modern automotive and aerospace engines. Today the processing and product advantages of Silastic LSRs are exploited in many existing and new applications. A broad product line is available both for general applications and for specific requirements. Moreover, many new applications are rapidly emerging to take advantage of the new Silastic F-LSRs.
Key Elements of Silastic LSR and F-LSR
Silastic LSRs and F-LSRs are liquids with viscosities that vary from easily pourable to paste. These two-component materials are mostly used in a 1 to 1 ratio and consist of polysiloxane polymers or copolymers, which are vulcanized by polyaddition. In addition F-LSRs are fluorinated.
Technical Service
The Dow Corning application technology and the customer service centers provide the full technical and sales support needed to run injection molding using Silastic LSR and F-LSR.
Packaging
Silastic LSR and F-LSR are supplied as lot matched kits in 200-litre drums or 20-litre pails. The exact packaging weight varies, depending on the density of the product. For detailed information please refer to the individual product data sheet.
Usable Life and Storage
When stored at or below 32C in the original unopened containers, Dow Corning guarantees the usable life of these products until the date indicated on the packaging and they will have a usable life of at least 6 months when shipped. This date is shown by the letters: EXP. (meaning expire) followed by four digits, which stand for the month (last day) and year. Example: EXP. 03/09 means use by March 31, 2009.
Handling Precautions A product safety data sheet should be obtained from your nearest
Dow Corning sales office prior to use.
Attention:
Before handling read the product information, product safety data sheet and container labels for safe end use and physical and/or health hazard information.
Back to content page
Dow Corning
no cure decomposition products (unlike peroxides) long pot life at room temperature yet very fast vulcanization above 150C Silastic LSRs are easier to mix and to process than Silastic HCR Rapid Cure F-LSRs are easier to mix and to process than high consistency FSRs easy to pigment, providing end product flexibility Silastic F-LSRs can be overmolded onto plastics that have a lower melting temperature
Faster Cycle Times
Silastic LSRs and F-LSRs are fully compounded, ready to process just two components, mixed 1:1 automated injection molding process similar to thermoplastic injection molding easy demolding with good hot tear rapid curing at elevated temperatures flashless molding with tight part size tolerance control post curing frequently not needed
Better End-Products
good direct bonding to specific insert components superior clarity as well as low odor and neutral taste Silastic LSRs are usable over a wide temperature range from -60C to + 180C for continuous use. F-LSRs are usable from -82C to 180C for continuous use. good elastic properties very good UV and ozone resistance as well as atmospheric ageing stability low moisture pick-up Silastic LSRs are resistant to many solvents Silastic F-LSRs are resistant at extreme temperatures to fuels, oils and other aggressive fluids good dielectric properties over a wide temperature range
Dow Corning
Applications
Silastic LSR
Silastic LSRs are widely used in injection molding, fabric coating, dipping and extrusion coating processes. Application areas are numerous including the automotive, aerospace, appliance, business machine, electrical and consumers industries.
Silastic F-LSR
Due to their FSR-like performance characteristics, Silastic F-LSRs can be used in injection molding to produce parts that must withstand fuels and oils at extreme temperatures. For example rubber seals, gaskets, diaphragms and other parts within modern engines. Because Silastic F-LSRs are true liquid rubbers they offer faster, easier production cycles than manufacturing techniques that use FSR, HNBR, Urethane, GFKM or AEM rubbers. They also offer a more precise manufacture.
Food Contact with Silastic LSR
Certain Silastic LSR grades comply with food additive regulation 177.2600 and BfR , XV, which covers rubber articles intended for repeated food contact, provided the rubber is processed using recommended conditions. If your processing conditions vary from these conditions then this product MAY NOT be in compliance with these regulations. Manufacturers should do their own testing to evaluate the level of total extractives for this product as formulated by them and processed under their specific conditions. For further details on the suitability of the product selected product for food contact applications, please refer to its individual Food Regulatory Profile.
Extrusion and Flat Textile Coating
LSRs are very suited to these processes for reasons of: solventless with low and versatile viscosity easy mixing and pigmentation rapid processing compared to solvent dispersions and usually allows a complete coating to be applied in a single pass primerless adhesion to glass and certain other substrates Meter mixed Silastic LSR can be dip-coated or fed to a crosshead for supported extrusion coating. Standard techniques are used for flat textile coating.
Pigmenting Silastic LSR and F-LSR
This is best done with Silastic LPX crosslinkable pigment masterbatches. Full details are available from Dow Corning.
Dow Corning
Shear Rate
(Pas)
1E+03
1E+02
Cone Sample
Plate
The graph above shows typical viscosity versus shear rate of some Silastic LSRs. These figures were measured on a cone/plate viscometer at 25C. The electrically conductive Silastic LSR Q3-3351 has a higher viscosity at low shear rates than the standard Silastic LSR. However, at shear rates occurring during the injection molding process, its viscosity is lower than the others. Therefore, it is not possible to extrapolate from the viscosity at low shear the actual viscosity during the injection process. Though this material can only be metered with a high consumption of energy the injection pressure should however be kept fairly low in order to avoid flash. Silastic F-LSR has a higher initial viscosity than regular LSR. However, at the shear rates occurring during the injection molding process, its viscosity reduces making it as easy to process as LSR.
Dow Corning
The shear rates which occur during the process are shown in the following diagram:
A
1E+04
Viscosity [Pas]
Pump/Mixer
1E+01
Injection Unit
1E+02 1E+03
Runner/Cavity
1E+04
The shearing rates are highest at the gates and in the cavities with values ranging up to 1 10-4 1/s. Viscosity here is often 10 to 100 times lower than in the pumps. These low viscosities allow the Silastic LSR and F-LSR to reach even the smallest gap during the injection process. Therefore, it is particularly important that all venting channels and other gaps are less than 5 to 7.5 m, otherwise flash will occur.
Injection The injection pressure depends mainly on the geometry of the runner.
It normally ranges from 100 to 1000 bar. Filling times for both Silastic LSR and F-LSR are approximately 0.5 to 3 seconds for a part size of 10 cm3. To ensure that the material is not scorched, the injection speed profile should provide enough material to fill the cavity before it begins to vulcanize.
Dow Corning
Material Cushion To avoid overloading we advise that the material cushion is driven
towards zero.
P re s s ure in the M o ld
Runner
50 40 30 20 10 0 0 0,5 1 1,5
Pressure [bar]
Time [s]
10
Pressure in the Cavity Cavity pressure commonly measures up to 300 bar. It rises gradually as Avoiding Flash the injected silicone expands upon rising temperature but this rising
pressure occurs before vulcanization starts. This means that you can fill the cavity up to 98-99% and the remaining space is filled by the expanding liquid silicone rubber. This helps to avoid flash, because the cavity pressure does not rise much compared to when it is fully filled.
Dow Corning
Material Supply Silastic LSR and Silastic F-LSR have two components that are
delivered at a rate of 1:1 from either a 200-litre drum or 20-litre pail. Hydraulic or pneumatic reciprocating pumps are used to feed the liquid silicone rubber through flexible pipes to a static mixer. Here the pressure in the silicone measures 150-220 bar. At this point 0.5 to 6 % color additive can be added. If more than one color is frequently used on the same machine or if more than one injection unit are supplied from the same pump, further additive pumps can be linked up.
Mixing The two main components and possibly an additive are delivered
through a static mixer, which is a pipe with staggered mixing vanes inside. This ensures they are thoroughly mixed into a homogeneous suspension.
Dosing The pressure of the material delivered through the pumps is reduced to
30-70 bar before it reaches the injection unit, which has been specially developed for liquid silicone rubber injection molding. The injection unit often has just one feeding screw for processing Silastic LSR or F-LSR. This means the proportion of compression is 1:1. To guarantee optimal mixing, feeding screws with an additional mixing unit in the metering zone are sometimes employed. Some special machines use a dynamic mixer combined with an injection piston to dose the material. Special attention should be given to the non-return valve. It must be equipped with an exact and reproducible closing mechanism to avoid variations in the final volume caused by leakage flow. Due to the very low viscosity (compared to thermoplastic melts), standard non-return valves are often too inert and do not always close immediately when the screw begins the injection process. Good results can be achieved with spring-loaded rings or with non-return valves that have very small closing distances for the particular application. The dosing speed should be chosen to: minimize the cycle time avoid partial curing of the material in the injection unit
Back Pressure The specific back pressure should be adjusted to 5-30 bar. Overmolding Silastic F-LSRs are particularly good in overmolding thermoplastic: Opportunities their fast curing time at lower temperature will not damage the thermoplastic insert. This allows a broad range of thermoplastic material to be overmolded.
Back to content page 10
Dow Corning
Vulcanization Speeds The vulcanization speed of liquid silicon rubber depends on and Cycle Times four main factors:
temperature of mold, temperature of possible inserts temperature of the silicone upon reaching the cavity geometry of the part (relation between surface area and volume) general vulcanization behavior and the chemistry of the curing (see also page 22)
Cycle times can be reduced (and therefore productivity increased) by: increasing the mold temperature pre-heating the injection barrel and cold runner to 40-80C with the use of a temperature controller using a faster curing material such as Silastic LC2004 Series Pre-heating the silicone that is about to be injected is recommended only for fully automated processes making larger items with a small surface-volume ratio. If the machine is interrupted in its cycle, the cooling system must be activated immediately to prevent the material curing. At this point it is important to note that the vulcanization time is often not the decisive factor for the overall cycle time. Demolding the rubber part often takes much longer. Also the dosage of the liquid silicone rubber in the injection barrel can be a major factor in cycle time. If a mold with a high number of cavities is being run (which as a single item would only need a short vulcanization time), the dosing unit may not be able to load the necessary shot volume fast enough, if this is the case dosing time will extend the cycle. To achieve the highest possible productivity, the machinery must be adjusted very precisely. However, the times for processes using air ejection of the rubber parts should not be too short if they are too short, they may wrongly activate the mold protection after a few cycles because some parts were not ejected. In many cases the curing time can be assessed at the planning stage, using a total vulcanization time of 4 to 6 sec/mm. This becomes longer with larger thicknesses of parts. More precise calculations can be made with the help of simulation software on a computer.
11
Dow Corning
Curing Behavior of Vinyl and hydrogen functional polysiloxanes are cured using a Silastic LSR/F-LSR platinum catalyst. This reaction can take place at room temperature
H H-C-H
but is much faster at higher temperatures. Once mixed Silastic LSR or Silastic F-LSR, when stored at room temperature, has a minimum usage time (pot life) of three days. When the curing of a liquid silicone rubber is measured on a rheometer, the torque is shown as a function of the test time. The graph shows the various stages of cure. In the beginning, the sample is mainly plastic and shows very little resistance to the deformation caused by the testing equipment. When the liquid silicone rubber begins to absorb the heat of the chamber, the torque begins to rise along with the start of vulcanization. The TC 2 value shows when 2 % of the maximum torque is reached during the test, and therefore indicates when curing starts.
Poly-DiM ethylSiloxane
H H CH
Catalyst
H H CH
+ Pt
H C H H
H-C Si C-H H O
H H
R Si O Si C H CH H H CH
H Si C-H O H
H H
H-C Si C-H H R H
H H-C-H H
H-C Si C-H
H H CH
H H
H O
HCH
The TC 90 value is also important. Here, 90 % of the maximum torque is reached and the curing is so much advanced that demolding is possible. At 25C it takes several weeks for the material to become completely vulcanized. At temperatures above 120C, however, this reaction takes only a few seconds.
Title: Silastic LSR Curing time as a Function of Temperature
Curing of 18 16 14 Torque [dNm] 12 10 8 6 4 2 0 0 1 2 3 4 5 Time [min] Measured with MDR at 120C 6 7
90 % Cured
R Si O Si C C Si C-H HCH H H CH H H H
H-C Si C-H H R H
Silastic
LSR
9280/50E 9780/50E
At molding temperatures of 170C to 210C, Silastic LSRs cure very quickly leading to a highly productive process.
1
Dow Corning
F-LSR 120C FSR 140C 10 9 8 7 6 5 4 Torque, lb-in 3 2 1 0 0.0 0.2 0.4 0.6 0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
Time, min
This graph shows a close link between the cure kinetics of Silastic F-LSR with higher temperatures. Temperature is a key factor: it should be low enough to allow injection without scorch but high enough to minimize cure time. Silastic F-LSRs have a very fast cure time at a lower temperature than a typical LSR. This means you can increase production output. Rubber parts with 2.8g weight and 1.4 mm thickness, have been successfully molded at temperatures lower than 140C with cure times of 15 seconds. Rubber parts have also been molded at temperatures slightly higher than 160C with cure times of 4 seconds but at these temperatures scorching may occur. If this happens simply change the molding conditions, for example by increasing the injection speed.
Post Curing If the finished rubber parts must meet certain guidelines such as BfR*
or FDA, post curing is essential. In this case volatiles escape from the molded part. When post-curing parts made with Silastic LSR or FLSR it is necessary to supply a fresh air flow of 80 to110 liters per minute and per kilogram of silicone rubber. Post curing can also help achieve some particularly high mechanical properties required from the silicone rubber. A typical post curing process takes place at 200C over a period of 4 hours in an oven with fresh air supply. Depending on the required properties of the finished rubber parts, post curing times and temperatures may be reduced. To fulfill the requirements of BfR* with respect to volatile content, the post curing should be fine-tuned using experimental trials.
Back to content page 1
Dow Corning
Shrinkage Even though the rubber parts do not shrink in the mold, they will
shrink after the demolding during the following cooling process. Silastic LSRs typically shrink 2.5 to 3 %, and Silastic F-LSRs typically shrink 3 to 3.5%.
pv t - D ia g ra m 9 2 8 0 / 5 0 E
1,025 0,975 0,925 0,875 0,825 50 100 150 200 250 1 bar 5 200 bar 400 bar 600 bar 800 bar
S hrink a ge 9 2 8 0 / 5 0 E
Shrinkage [%]
Temperature [C]
Temperature [C]
This shrinkage during the cooling depends on several factors: tool temperature and demolding temperature pressure in the cavity and consequently the compression of the materials location of injection point (shrinkage in the direction of the material flow is usually higher than shrinkage perpendicular to the direction of flow) the dimension of the part (the shrinkage of thicker rubber parts is lower than that of thinner rubber parts) post curing the rubber part causes additional shrinkage of about 0.5 to 0.7 %
1
Dow Corning
Parting Line Deciding where the parting line should be is one of the first steps in
the development of the injection mold. The venting, which is necessary for the material flow, takes place through special channels inserted into the parting line. The parting line should therefore be located in the area that the material reaches last. This avoids air entrapments and the mechanical strength of the rubber part is not reduced along the weld line. On the molded part the separation from the mold is always recognizable later on. This area is very sensitive due to the low viscosity of the silicone and can easily bring about flash. Demolding the rubber parts at a later time is influenced by the geometry of the rubber part and location of the parting line. Under cuts here can help ensure that the rubber part remains in the desired cavity half.
Venting The air that is enclosed in the cavity is first compressed by the injected
silicone and then expelled through the venting channels. If the air cannot escape entirely, air entrapments in the rubber part will occur, which can often be recognized by a white edge along the rubber part. Special venting channels with a 1 to 3 mm width and a depth varying between 0.004 to 0.005 mm are inserted into the parting line so the air can escape. Optimum venting is created by a vacuum. To produce such a vacuum, the mold stops during the closing movement at 0.5 to 2 mm before it is completely closed. A gasket is built into the parting line, so a vacuum pump can draw the air from the cavities. Only when the vacuum has reached a certain reduced pressure or a time cycle has come to its end, will the machine close the mold completely and the injection process restarted. Some modern injection molding machines offer variable clamping forces. Here the mold is held together with low force until the cavities are filled to 90-95 %, the low clamping force allows the air to escape more easily through the parting line. Then switching to the necessary clamping force avoids flash caused by the expanding silicone.
1
Dow Corning
Injection Point The type of gate depends on a number of factors. Using a system of
cold runners fully exploits the technical advantages of liquid silicone rubber and also maximizes productivity. The aim is to produce the rubber parts without having to remove any sprue, which can be very labor intensive. Avoiding sprue removal also saves considerable amounts of material, and leads to faster cycle times. Some injection nozzles can open and close with the help of a needle. These needles shut off nozzles which are built into the mold or in some special cases are fixed to the injection barrel instead of the standard nozzle. Nowadays pneumatically controlled needle shut off nozzles can be obtained as a standard mold part and as such can be built into various positions of the injection mold by the toolmaker. Some moldmakers are specialized in the development of open cold runner systems. Due to their small size, the open cold runner systems can provide many injection points in very limited space. This technology also enables the production, even on small injection molding machines, of large numbers of high quality rubber parts where no sprue gate needs to be removed. When such cold runner systems are employed, it is necessary to separate the temperatures between the hot cavity and the cold runner. This ensures that the material does not start to cure if the cold runner is too hot. Furthermore, if the cooling is too strong, too much heat is drawn from the hot mold in the gate region - which in turn causes that area of silicone to insufficiently cure. If the rubber parts are injected in a more conventional sprue (such as submarine or cone gate) small diameters should always be selected in the beginning. This is because in these areas the low viscosity material can easily flow and does not need large diameters. The diameter of the feed point is between 0.2 and 0.5 mm. It is important to balance the layout of the whole runner system in such a way that all cavities are filled evenly. Filling studies can be used to confirm this information or you can use filling simulation software to design the runner during the development of the mold.
20 -3 0
45
0,2-0,5
heating of Silastic lSr through dissipation: T p/( x cp) p pressure gradient density Silastic LSR cp heat capacity Silastic LSR For Silastic LSR, the increase is approximately 4-6 K/100 bar applied NOTE: The warming resulting from the friction during the injection may be neglected
Demolding and Vulcanized liquid silicone rubber sticks to metallic surfaces. The Ejection Systems silicone rubber molded part is also flexible. These two factors can
sometimes make demolding particularly difficult. However, the high hot tear resistance of Silastic LSR and F-LSR makes it possible to easily demold rubber parts even with big undercuts without damage.
1
Dow Corning
The demolding technologies most used are: stripper plate ejector pin air ejection roller sweep draw-off plate robotic handling When ejection systems are used, they must have narrow tolerances. Ejector Flash will occur if there is too much clearance between ejector pin and bushing guide or if this has been enlarged by wear over time. Good results are achieved with mushroom-shaped or tapered ejectors where an improved sealing effect is favored by increased contact pressure. Aireject
Mushroom-shaped and tapered ejector pin:
Cavity
Ejector Cavity
Pin Cavity
Aireject
Aireject
Mold Materials Retainer plates are fabricated from unalloyed tool steel.
Pin
When developing molds for highly abrasive materials, ensure that the high-wear areas can be exchanged separately this avoids having to Aireject replace the whole injection mold.
The mold plates containing the cavities are preferably produced from forged steel, tempered later and possibly nitrided. Steel-No.: 1.2343 DIN-Code: X 38 CrMoV 5 1 For highly filled Silastic LSR and F-LSR, such as oil resistant grades, it is recommended to use even harder materials such as steel plated with flash chrome or powder metallurgy steel developed specifically for this application. Steel-No.: 1.2379 DIN-Code: X 155 CrVMo 12 1
Back to content page 1
Dow Corning
Temperature Insulating
1.1730
1.2312
1.2343 or 1.2379
Sketch of a cold runner mold for Silastic LSR and F-LSR Surface roughness: Spark erosion: 0.5 - 3.5 Ra Grind, polish: 0.05 - 1 Ra
The surface of the cavities influences the process in different ways: The rubber part exactly duplicates the surface of the steel, hence this surface fulfils various optical requirements. Polished steel must be used for the production of transparent rubber parts. An eroded surface normally provides less adhesion between the liquid silicone rubber and the mold than a polished surface, so demolding may be specifically designed. Steel with a Titanium/Nickel-treated surface has a very high wear resistance.
Unheated cores can be exposed to great changes in temperature due to prolonged break times or from the blow-off air. When the temperature falls too low at this point, the material cures at a slower rate and this may cause demolding difficulties because of the stickiness of liquid silicone rubber. The distance between heating cartridges and the parting line should be high enough so that they cannot bend or deform the plate. Uneven plates may prevent a flash-free process. If the mold is equipped with a cold runner system, an exact separation between hot and cold mold must be provided. Here special titanium alloys, such as 3.7165 (Ti Al 6 V4), can be used as these have a much lower thermal conductivity than other types of steel. For molds that are heated entirely, heat-insulating plates should be placed between mold and mold plates to minimize heat loss.
1
Dow Corning
Selection of machine
Clamping Force Before selecting a machine, the clamping force must first be calculated.
The expansion of the silicone rubber in the hot mold causes the cavity pressure to rise up to 400 bar. The force needed to clamp the mold can be calculated by multiplying the projected surface of all rubber parts with the cavity pressure.
Acircle = D2/4 example: 6-cavity baby nipple mold
Nipple diameter = 39 mm Projected surface A = 6 r (39/2) r = 7167.54 mm2 Cavity pressure 400 bar 400 bar = 40 N/mm2 F = p r A = 40 N/mm2 r 7167.54 mm2 F = 286702 N clamping force is required. This corresponds to an injection molding machine with a designated clamping force > 290 kN (or the equivalent of a 30-tonne weight)
Injection Unit The diameter of the injection screw should be chosen in such a manner
that the stroke of the screw ranges between 1 - 5 D. This guarantees a stable operating process for the injection unit. With a stroke of less than 1 D the mixing of the screw is insufficient and the movement control for the machinery is not precise enough.
Meter Mixer There are different types of meter mixing units. Hydraulic and
pneumatic driving cylinders are the main differences. The metermixing unit can pump the material from 20-liter pails or 200-liter drums.
Equipment Adjustment Silastic F-LSRs have higher viscosity and exceptionally fast cure rates,
therefore it is recommended to use 1-inch (25.4 mm) diameter hoses to supply material from the feeding pumps to the static mixer. In addition, a static mixer larger than inch (12.7 mm) should be used. These changes will help ensure that the injection screw can refill before the next cycle begins. It is also recommended not to use a screen pack, but if a screen pack is used make sure it is bigger than 300 micron.
1
Dow Corning
some cases it is possible to produce the Silastic LSR and F-LSR rubber part directly in the place required for its final use. For example, producing a gasket of silicone rubber on a housing of nylon once entailed making both parts (housing and gasket) on separate injection molding machines and then connecting them in an extra assembling process. But with Silastic LSR or F-LSR you can produce products like these in a high-quality and cost-efficient way with two-component injection molding. For this, two main procedures are commonly used:
1: Two separate injection molding machines
The first part will be injected with thermoplastic on a standard injection molding machine. Depending on the degree of automation, the demolding is done by automatic handling or manually. Afterwards the thermoplastic part is placed directly in the injection molding machine for the liquid silicone rubber, which is standing just next to the first machine. The thermoplastic part represents a part of the cavity during the following injection molding process. The actual injection mold provides the outer shape of the liquid silicone rubber gasket. Parallel to the molding of the liquid silicone rubber, the machine for the thermoplastic starts the next cycle. The advantage of this system is that you can use both machines independently for different projects. It is also much easier to control the thermal conditions. For example, the tool temperature for a technical thermoplastic such as glass-fiber reinforced nylon PA-GF or polybutylenetheraphthalate PBT is approximately 70 to 110C (Check the recommendations of the raw material supplier). The residual heat of the injected thermoplastic part is high enough to reach a fast enough curing in the hot (170 to 190C) Silastic LSR mold. The bonding of both materials can be achieved mechanically by undercuts or chemically with the use of a primer. In some special cases it may be possible to use a self-adhering Silastic LSR.
2: Two-component injection molding machine
Alternatively you can use a two-component injection molding machine. In this case both materials will be injected on one machine with two injection units. This machine has only one mold that contains both cavities: one for the thermoplastic and one for the liquid silicone rubber.
0
Dow Corning
Moving the molded parts to the respective injection point is done by rotating the mold plate or by using a turning or sliding table. It is difficult to set up the optimum temperature profile for each material. One possibility is to vary the temperature in the mold: cold for the thermoplastic and hot for the liquid silicone rubber. But this requires a high investment in the mold structure and in its temperature control unit. The mold temperature can also be adapted in such a way that the thermoplastic part cools down sufficiently to enable demolding without deforming the part - while simultaneously allowing the temperature to be still high enough to achieve an efficient enough curing of the liquid silicone rubber. A tool temperature range of 110 to 130C for Silastic LSR gives good results with this method. Due to the need for a faster curing, a liquid silicone rubber such as Silastic 9780/xx E should be used. This type of Silastic LSR vulcanizes at lower tool temperatures fast enough to achieve an efficient process. It is certainly possible to produce other two-component rubber parts in this way or with similar procedures: silicone with silicone for multi-color rubber parts electrically conductive silicone in combination with insulating ones for high voltage applications injection of silicone gaskets on aluminum housings CIPG (Cured In Place Gasket)
Silicone Gasket
Thermoplastic Housing
The composition of various silicones, as for the high voltage technology example, gives the advantage that the welding line of both materials is almost as stable as the basic material.
1
Dow Corning
Injection Molding of One Component Silastic HCR Rapid Cure HCR (High Consistency Rubber) as opposed to LSR (Liquid Silicone Rubber)
The oldest way to produce silicone rubber parts is still widely used today: injection molding of high consistency rubber Silastic HCR Rapid Cure. The silicone rubber is fed as an endless rope preform or as a block via a special stuffing piston to the injection unit. Compared to liquid silicone rubbers, there are more bases to compound together to achieve specific final properties. This makes it possible to produce small numbers of rubber parts with a custom developed material that fulfils these special requirements. Using these newly developed products, you can overcome the disadvantage of the low productivity caused by the much slower curing time of peroxide curing materials. The use of a platinum catalyzed addition curing system reduces vulcanization time by up to 70% compared to peroxide curing silicone. Silastic HCR RapidCure, which is delivered as a stable-to-store, 1-component ready-mix, offers shorter curing times and thereby much higher outputs compared to the use of peroxide curing compounds.
Curing Behavior of SILASTIC Silicone Rubber
35 30 25 20 15 10 Torque 5 0 Silastic LSR RapidCure Silastic HCR Rapid Cure 0Time 1 2 3 4
Measured with Monsanto MDR at 170C
Thanks to its vulcanization behavior, Silastic HCR Rapid Cure is not so sensitive to tool temperature variations as peroxide curing silicones are even with short curing times. Thereby, deformations caused by the demolding process can be prevented even with a lower tool temperature. This makes it possible to produce rubber parts with narrow tolerances. Addition curing silicones are uninhibited by oxygen making the demolding easier. The surface also feels dryer than with peroxide materials. As with Silastic LSR, during the production using Silastic HCR Rapid Cure, no peroxide decomposition products escape from the material, and there is none of the typical peroxide odor during production.
Back to content page
Dow Corning
for Silastic HCR Rapid Cure silicones is generally comparable with the guidelines for liquid silicone rubber. The injection barrel is designed specifically for the use of these materials. Various machine constructions are developed by machine suppliers to cover this wide range of applications. The use of a compression screw is common with the various injection molding methods and a non-return valve is similar to the ones used for thermoplastic injection molding.
The production and tool design
The runners and the injection points should have slightly larger dimensions due to the higher viscosity of Silastic HCR Rapid Cure compared to Silastic LSR. As a result of the higher viscosity, flash is also not so critical. Thereby the venting channels may have a size of 0.01 mm. The total curing time depends on the mold temperature and the geometry of the rubber part: for Silastic HCR Rapid Cure with a peroxide curing system a typical curing value is about 15 sec/mm. for a rubber part made with addition cured Silastic HCR Rapid Cure a typical curing value is between 5 to 7 sec/mm.
Dow Corning
Injection Stroke If demolding makes it possible, it is good to try to underfill the and Flow first injection molded part so that an overload is avoided. In the
following cycles the dosing volume can be gradually increased to the final shot size.
Not Filled Flash
Weight
Pressure
28
29
30 Dosage Volume
31 [cm3]
Article Good
32
33
Best results are achieved when the cavities are filled precisely to 98-99 % of the cavity volume. The thermal expansion of the liquid silicone rubber fills the cavity completely during the curing time. This can be examined, for instance, by weighing the finished rubber parts. To prevent an overload, all parameters should be kept low for the first injection.
Back to content page
Dow Corning
The injection speed and the maximum injection pressure should then be chosen in such a way that the cavities are filled in a period of 0.5 to 3 seconds. Towards the end of the filling period the injection speed should be reduced to enable the air enclosed in the cavity to escape through the vents.
Switchover and During the injection molding of liquid silicone rubber, holding Holding Pressure pressure ensures that no material is pushed back from the cavity
out of the gate. Pressures of 50 to 200 bar (specific material pressure) are sufficient. The holding pressure time depends mainly on the type and geometry of the gate. If a needle shut off nozzle is employed, holding pressure time can often be less than one second as the discharge of the material is hindered by the needle shut off. With open cold runner systems, however, holding pressure must be maintained until the liquid silicone rubber is so far vulcanized at the gate, that no material can escape from the cavity. Holding pressure time depends largely on the geometry of the gate and is commonly 0.5 to 4 seconds for Silastic LSR and 3 to 6 seconds for Silastic F-LSR. The switchover from injection to holding pressure should be chosen in such a way that the holding pressure sets in very late and fills the cavity a little. This facilitates a flash-free injection.
Curing Time The curing time for the first trials should be selected in such a way that
the liquid silicone rubber cures securely and can be demolded without damaging the rubber part and without uncured rubber remaining in the cavity. A typical curing time is between 3 to 5 sec/mm. However, the curing time can be incrementally reduced until problems such as deforming or stickiness occur. Then the curing time should be raised by about 5 to 10 % to ensure a safe process.
Demolding At the start of production, the rubber parts may tend to stick on the
mold steel. However, this will improve after several cycles as siloxanes escape from the liquid silicone rubber and deposit a layer siloxane on the steel section. To prevent sticking at the initial cycles a silicone-free release agent can be used as a demolding aid. A mixture of water and liquid soap, which can be wiped on with a cloth or sprayed on thinly with a diffuser, is often efficient and economical.
Dow Corning
Production End If the machine stands still for three days, as for instance on the and Clean-Up weekend, no special measures need to be taken as during this time the
mixed liquid silicone rubber vulcanizes only slightly in a cooled barrel. That is because at temperatures below 35C mixed material will remain processable for a minimum of three days, unless otherwise stated. If the machine stands still for longer than three days, the mixer, the injection unit and the cold runner should be lushed with the B-component. Parts which carry mixed material can also be kept in a freezer to prevent curing for a longer period of time. Even if the production runs almost without interruption, about every six months the mixer and the injection unit should be cleaned thoroughly. This ensures that cured particles in the mixing unit do not detach themselves and thereby plug up the cold runner or enter the mold cavity. Cured Silastic F-LSRs have high solubility in polar solvent such as ester or ketons based solvents. Use of such fluid will help remove easily cured material.
If the heaters are turned off at the end of production, the cooling systems for the cold runner and for the shut-off nozzle of the injection unit must continue to run. This prevents parts carrying mixed liquid silicone rubber from being warmed by radiating heat, which causes a shortening of the pot life. If the machine is interrupted in its cycle, shortly afterwards the cooling systems must be turned on to prevent the material curing.
Dow Corning
Solution
Raise injection velocity and possibly injection pressure Enlarge dosing volume See Point 3) Bubbles/Burners Lower tool temperature Delay switchover Increase holding pressure Check radial screw clearance and non return valve Check sprue system for soiling or precured area Check dimensions of sprue and possibly enlarge Balance runner and gate Clean system
g. Cold runner or sprue dimensions faulty h. Uneven filling of cavities i. Precuring in injection unit or supply lines
2.
a. b. c.
Dow Corning
3.
Cause
a. b. c. Injection speed or pressure too high Tool temperature too high Venting channels soiled or not properly dimensioned
Solution
Reduce injection velocity and possibly pressure Reduce tool temperature Clean mold Deepen vents Reduce clamping force Check vacuum pump Check gasket for defect spots Prolong time for building up vacuum De-air the unit Check gaskets Balance runner and gat
d. Vacuum insufficient
e. f.
4.
Cause
a. b. Vulcanization time too short Tool temperature too low
Solution
Prolong vulcanization time Raise temperature Check heaters and thermocouples Check if temperature is even Shorten break time Check meter mixer for fluctuation of pressure Clean supply lines and mixer from procured particles and areas Check that no sulphur or tin are contaminating the Silastic LSR unit (occurs often when organic rubbers are produced close to Silastic LSR
c.
d. Curing inhibited
5. Scorch. Precuring of - Part shows streaks the material during - Strongly appearing flow lines the injection process - Orange skin Cause
a. b. Injection speed is too low Tool temperature too high
Solution
Raise injection velocity and possibly pressure Lower mold temperature and possibly cold runner temperature
Dow Corning
6. Precured particles in - Cured particles appearing in the part finished article - Cured sprue visible in article Cause
a. Temperature of cold runner at injection point is not low enough Material leaks from the injection point
Solution
Control or improve cooling of cold runner Lower tool temperature at the gate Decompression of material in the cold runner with open system insufficient Shut off needles have too much clearance
b.
f.
Precured particles are spooled Clean mixed material leading areas out from the injection unit or mixer
7. Cause
a. b. c.
Problems with - Article not ejected from cavity demolding - Runner is not separating from part Solution
Lower mould temperature Reduce holding pressure or time Shorten vulcanisation time Optimise undercuts Treat mould surfaces or adjust roughness Combine ejector-pins, -brushes, -plates, with air eject and/or roller sweep
Tool temperature too high Holding pressure too long or too high Curing time too long
8. Incorrect dimension - Article is deformed after demolding of part - Part dimensions out of range Cause
a. b. Curing insufficient Shrinkage changed
Solution
Prolong vulcanisation time Control and optimise temperature of mould Check for even tool temperature Adjust injection parameters to get required cavity pressure
Dow Corning
Cause
a. Dosing time varies and is sometimes longer than curing time
Solution
Adjust pressure in the pumping unit evenly Remove precured material from the mixer Increase dosing speed Optimise back pressure Control hydraulic system of the machine Check non-return valve Control injection parameters Lower temperature of cold runner Control for even dosing volume Check non-return valve
f.
10.
Potlife Material cures in - Starting difficulties after a longer production break injection unit - Longer injection and dosing times at production start Cause Solution
Check cooling of injection unit Spool unit with A-component before a standstill of more than three days Disconnect injection unit from the hot mould even at short breaks Continue cooling of cold runner after switching off the tool heating
0
How To Contact Us
Dow Corning has sales offices, manufacturing sites, as well as science and technology laboratories around the globe. For more information, visit www.dowcorning.com, or call one of our primary locations listed here.
LIMITED WARRANTY INFORMATION - PLEASE READ CAREFULLY The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer's tests to ensure that Dow Corning's products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Dow Corning's sole warranty is that the product will meet the Dow Corning sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. DOW CORNING SPECIFICALLY DISCLAIMS ANY OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. DOW CORNING DISCLAIMS LIABILITY FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. WE HELP YOU INVENT THE FUTURE is a trademark of Dow Corning Corporation. Dow Corning and Silastic are registered trademarks of Dow Corning Corporation. 2008 Dow Corning Corporation. All rights reserved. Cover photo - AV01065 / AV00620