Engineering Software: Brayton Cycle (Gas Turbine) For Propulsion Application Analysis
Engineering Software: Brayton Cycle (Gas Turbine) For Propulsion Application Analysis
Engineering Software
P.O. Box 1180, Germantown, MD 20875 Phone: (301) 540-3605 FAX: (301) 540-3605 E-Mail: info@engineering-4e.com Web Site: http://www.engineering-4e.com
Brayton Cycle (Gas Turbine) for Propulsion Application Analysis by Engineering Software
-- i --
-- ii --
-- iii --
-- iv --
Table of Contents
Brayton Cycle (Gas Turbine) for Propulsion Application .............................................................................................2 Analysis .....................................................................................................................................................................2 Assumptions...............................................................................................................................................................9 Governing Equations ...............................................................................................................................................10 Input Data ................................................................................................................................................................10 Results .....................................................................................................................................................................11 Conclusions..............................................................................................................................................................12
-- 1 --
Analysis
In the presented Brayton Cycle analysis, only air is considered as the working fluid behaving as a perfect gas -- specific heat has a constant value. Ideal gas state equation is valid -- pv = RT. A gas turbine is a heat engine that uses a high temperature, high pressure gas as the working fluid. Combustion of a fuel in air is usually used to produce the needed temperatures and pressures in the gas turbine, which is why gas turbines are often referred to as combustion turbines. Expansion of the high temperature, high pressure working fluid takes place in the gas turbine. The gas turbine shaft rotation drives an electric generator and a compressor for the working fluid, air, used in the gas turbine combustor. Many gas turbines also use a heat exchanger called a recouperator to impart turbine exhaust heat into the combustor's air/fuel mixture. Gas turbines produce high quality heat that can be used to generate steam for combined heat and power and combined-cycle applications, significantly enhancing efficiency. Air is compressed, isentropically, along line 1-2 by a compressor and it enters a combustor. At a constant pressure, combustion takes place (fuel is added to the combustor and the air temperature raises) and/or heat gets added to air. High temperature air exits the combustor at point 3. Then air enters a gas turbine where an isentropic expansion occurs, producing power. Air exits the gas turbine at point 4. It should be mentioned that air at point 1 enters the compressor and the cycle is repeated. Figure 1 presents a Brayton Cycle schematic layout.
-- 2 --
Figure 1 - Brayton Cycle Schematic Layout Figure 2 presents a Brayton Cycle temperature vs entropy diagram.
-- 3 --
Figure 2 - Brayton Cycle Temperature vs Entropy Diagram In order to keep the scope of thrust analysis simple, air exiting turbine expands to the atmospheric conditions - exit pressure is equal to the ambient pressure (p1 = p4). It should be pointed out that this material deals with the open Brayton Cycle. The way how the T - s diagram is presented, it describes a closed Brayton Cycle -- this would require a heat exchanger after point 4 where the working fluid would be cooled down to point 1 and the cycle repeats. Therefore, the T s diagram is presented as a closed Brayton Cycle to allow easier understanding and derivation of the Brayton Cycle thermal efficiency -- heat addition and heat rejection. The gas turbine and compressor are connected by shaft so the considerable amount of work done on the gas turbine is used to power the compressor. Propulsion is provided by the difference of gas turbine expansion minus the compressor power requirements: Thrust = vm
-- 4 --
v - working fluid velocity [m/s] cp - specific heat at constant pressure [kJ/kg*K] T1, T2, T3, T4 - temperature values at points 1, 2, 3 and 4 [K] m - working fluid mass flow rate [kg/s] It can be noticed from the T - s diagram that the work done on the gas turbine is greater than the work necessary to power the compressor -- constant pressure lines in the T - s diagram diverge by going to the right side (entropy wise). The thermal cycle efficiency can be given as a function of specific external work (specific net power output) and heat added to the working fluid as follows: = w/qh = (wt - wc)/qh = (qh - ql)/qh or = 1 - ql/qh = 1 - (cp(T4 - T1))/(cp(T3 - T2)) = 1 - (T1(T4/T1 - 1))/(T2(T3/T2 - 1)) where - thermal efficiency [/] w - specific external work (specific net power output) [kJ/kg] wt - expansion specific power output [kJ/kg] wc - compression specific power input [kJ/kg] W - external work (net power output) [kW] W t - expansion power output [kW] W c - compression power input [kW] qh - heat added to the working fluid [kJ/kg] ql - heat rejected from the working fluid [kJ/kg] cp - specific heat at constant pressure [kJ/kg*K] cv - specific heat at constant volume [kJ/kg*K] -- 5 --
-- 6 --
Figure 3 - Brayton Cycle Efficiency Here, two general performance trends are considered. First, impact of the gas turbine inlet temperature and compression ratio on the Brayton Cycle specific propulsion output and second, impact of the working fluid mass flow rate on the Brayton Cycle propulsion output. Figure 4 presents the results of the first performance trend, while Figure 5 presents the results of the second trend.
-- 7 --
-- 8 --
Figure 5 - Brayton Cycle Propulsion Output One can notice that the Brayton Cycle efficiency increases with an increase in the compression ratio. One can notice that the Brayton Cycle specific propulsion output increases with an increase in the gas turbine inlet temperature. Furthermore, the increase is greater for the higher compression ratio. One can notice that the Brayton Cycle propulsion output increases with an increase in the working fluid mass flow rate. The increase is greater for the higher compression ratio.
Assumptions
Compression and expansion processes are reversible and adiabatic isentropic. The working fluid has the same composition throughout the cycle. Ideal gas state equation is valid -- pv = RT. Air behaves as a perfect gas -- specific heat has a constant value.
-- 9 --
Brayton Cycle (Gas Turbine) for Propulsion Application Analysis Governing Equations
T2/T1 = (p2/p1) p2/p1 = (T2/T1) T3/T4 = (p3/p4) p3/p4 = (T3/T4) = cp/cv pv = RT w = qh - ql w = cp(T3 - T2) - cp(T4 - T1) W = (cp(T3 - T2) - cp(T4 - T1))m = 1 - 1/rp
(-1)/ (-1/) /(-1) (-1/) /(-1)
rp = p2/p1 v /2 = cp((T3 - T2) - (T4 - T1)) v = (2cp((T3 - T2) - (T4 - T1))) Thrust = vm
1/2 2
Input Data
T1 = 298 [K] p1 = 1 [atm] T3 = 900, 1,200 and 1,500 [K] p3 = 5 and 15 [atm] cp = 1.004 [kJ/kg*K] = cp/cv - for air = 1.4 [/] m = 50, 100 and 150 [kg/s]
-- 10 --
Specific Propulsion Output vs Compression Ratio for a few Gas Turbine Inlet Values Gas Turbine Specific Propulsion Inlet Temperature [N/kg/s] [K] Compression Ratio 900 1,200 1,500 [/] 5 15 563 524 734 774 872 961
Propulsion Output vs Compression Ratio for a few Mass Flow Rates Propulsion [kN] Compression Ratio [/] 5 15 Mass Flow Rate [kg/s] 50 100 150
-- 11 --
-- 12 --