85XX (Scanner) 1
85XX (Scanner) 1
85XX (Scanner) 1
Features
Micro-controller based advanced process scanner 8/16/24 channel configuration Universal input for each channel-mix Most flexible, user defined alarm/trip logic
Masibus' continues to be the leader in the process scanner market with its innovative product features. Model 85XX is Masibus' flagship product designed for versatile industrial monitoring and machine protection applications. Model 85XX is the latest and most advanced multi-channel monitoring and alarm annunciation system. This is one of the popular models among our OEMs & end users. Our scanner product range is now serving market needs for more than 20 years & still going strong due its excellent performance, stability & reliability. Model 85XX features configurable and universal input types per channel and displays sequentially in engineering unit. Model 85XX is modular in design and all I/O cards are plug-in type. Model 85XX comes in three variations 8/16/24 channels. 8/16 Channel scanner is capable of field upgrade for higher channels. In addition to most of popular process inputs, Model 85XX can also accept special RTDs like Cu-53 & Pt-46 3W. Option for channel to channel online isolation up to 125V AC and 300V DC and off-line isolation up to 500VDC is available for critical applications. The terminal back-plate is pluggable type which can be detached from the instrument without removing field connections, saving lot of maintenance time. This unit is fully programmable, configurable from front keys and also by software. Calibration is done digitally using front keys, without trim-pots. Model 85XX comes with password protection for all configurable data. User can program individual alarm and trip set points and logic individually or in group. Channels can be configured up to 6 groups with two relay outputs per group. Two discrete LEDs are provided per channel for visual annunciation. Model 85XX also has optional retransmission output (up to 4) which are user configurable channel or group mapping. Model 85XX also provides serial communication as an option.
Upto 4 Retransmission output (Isolated) RS 485 Serial communication Direct serial printer interface 48 open collector outputs Channel to channel input isolation Weather proof/ flame proof enclosure
Ambient, Zero and span adjustable by digital calibration through front panel keys. No trim- pots Zero Span Calibration of output through front panel keys One shot Calibration of both input and output Self check calibration through front panel keys Verify, Increase, Decrease, Auto/Man, Next/Group Check, Skip/Self Check, Al1/Al2, Scan Time/Print Time and Enter/ ACK keys for operation, programming & calibration Isolated RS232/485 Serial Communication MODBUS RTU or Standard Serial Printer Output
Event logging: Memory Capacity: 1MB Flash Real Time Clock Data Save: Measured Value with Time stamping. Channel Selection: Any Channel can be configured for data logging. OR Data Logging on demand, separate key available as DATA LOGGING facilitates the user to log the Required channel data on its invoking. Max. total records : 23800 Note: Once datalogging facility is opted in Scanner, PC based mscan software is supplied as standard for scanner configuration, calibration and fetching logged data from scanner memory.
OPTIONS FOR AUXILIARY OUTPUTS Relay card 2relay/1relay(per group) Slot 1 3 groups(1 to 3 ) with 2 set points/ 6 groups(1 to 6) with 1 set point Slot 2 3 groups(4 to 6) with 2 set points 6 groups(7 to 12) with 1 set point Common Description 2A@230V A.C. with N.O./C/N.C. Relay Mapping possible with number of channels Two Isolated Retransmission groups (Gr. No.: 1 and 2) 24 Open Collector Outputs Analog Output Card Open Collector Card Printer Card
Groups:- MAX or MIN Outputs:- 4-20mA Accuracy:- 0.25% of Range Load:- 250 Ohms 24V D.C. @ 100mA externally wet Contacts Parallel printer port
C M Y K
NOTE: The possible combinations are explained in the operational manual in Topic no. 8.
C M Y K
Protection Input range protection This restricts accidental wrong setting of set-point Instrument displays 'OVER' and 'UNDR' Upscale/downscale (programmable)
51
85XX
ORDERING CODE
Model 85XX X No of Input XX Input type/Configuration X X Datalogging N None Y Yes # 8 Eight A Sixteen NF Non Iso. Fix NM Non Iso. Mix Isolated Fix Isolated Mix 1 2 3 4 5 6 7 9 A B C D E F S
X - Specify from table
PS XX
Communication X
Display Col. X XX
Mounting XX
Auxiliary o/p
OC 0 0 1 0 0 2 0 0
AO 0 0 0 1 0 0 2 1
B Twenty four IF IM
0, 1, 2 - Number of cards Note: 1. With Mix input option-No AO card 2. If printer parallel option is selected RR, OO, AA, RA option is not available.
C M Y K All specifications are subject to change without notice due technology reasons.
Doc.ref.CB-2/85XX/R2/0110