Polaris Brochure
Polaris Brochure
Polaris Brochure
For all these reasons, your Polaris heat exchanger is a better choice than a shell-and-tube substitute. Compact design enables efficient plate heat exchangers to accomplish the same work in far less space than shelland-tube models. Close temperature approach maximizes temperature differentials and minimizes surface requirements. Elimination of cross contamination is assured by the Polaris gasket design. Low hold-up volume gives Polaris users shorter response times and better process control. Fouling is minimized with Polaris PHEs Versatility, expandability, and easy maintenance are built into every Polaris unit.
Plate heat exchangers from Polaris bring maximum effectiveness and efficiency to an array of challenging applications from HVAC specialties to automotive and general industrial needs, from food processing requirements to the special demands of chemical and pharmaceutical manufacturers. In every field, Polaris PHEs are recognized for outstanding quality in design and construction quality that proves out in long life, economical and trouble-free daily operation, and limited repair and maintenance schedules. Its a result that grows out of the most current heat-exchange technology, given form by exacting standards in plate pressing and unit assembly. Todays Polaris relies on extensive manufacturing capabilities at our newgeneration factory in Louisville, Ky., an industrial center created specifically to apply American know-how to Western Hemisphere PHE markets. And we also deliver prompt, reliable service on estimates, installation, parts, consultation, and repairs from our U.S. headquarters in New Jersey. It all adds up to a company that offers the same caliber of quality in its services thats long been established in its products. Thats Polaris PHE Americas premier provider of plate heat exchangers.
T H E P O L A R I S P L AT E - L O C K S Y S T E M Precise Alignment and Dependable Sealing A patented locking lip at the hanger and guide sections of each Polaris plate fastens plates securely together during the critical tightening operation. The Plate-Lock System keeps plates and gaskets tightly aligned, and ensures a tight seal even at high working temperatures.
THE POLARIS CLIP-TITE GASKET An Advanced Glue-free System Clip-Tite gasketing from Polaris offers a combination of positive fluid separation, economy, and easy of use thats perfect for most applications. Integrated gasket clips fasten securely to the plate stampings. And because Clip-Tite gaskets can be fastened without tools, theyre simple to replace. For applications with food or special sanitary requirements, choose glueless Polaris Pres-Tite gaskets.
Polaris quality demands careful attention to the materials and craftsmanship in every heat exchanger we make. Heres why you can expect superb efficiency, low maintenance, and long life from your Polaris unit.
BRAZED PHEs Ideal for refrigeration and process applications, Polaris brazed heat exchangers offer outstanding performance. Available with copper or nickel brazing, these units give you critical advantages:
I I I I I
P L AT E - L O C K P O S I T I V E A L I G N M E N T S Y S T E M A special locking lip secures the connection between plates, keeping them precisely aligned and tightly sealed even at high working pressures. A Polaris exclusive! P L AT E S E A L I N G S Y S T E M S Polaris provides the proper plate sealing system for a wide range of applications. Choose from glued gaskets or Clip-Tite and Press-Tite glueless gaskets. H E A V Y- D U T Y F R A M E H E A D S Polaris frame heads are built thicker to deliver even pressure to the plate pack. They eliminate the need for inferior welded-frame reinforcements. Opening the exchanger is fast and easy. V E R S AT I L E C O N S T R U C T I O N Polaris heat exchangers feature bolted construction for strength and accessibility. They can be assembled at the job site, and are easily expanded. OPTIONAL PROTECTIVE SHROUD This safety feature complies with all applicable OSHA requirements. Polaris also offers insulated shrouds to avoid condensation in hot locations. H E AT T R A N S F E R P L AT E S Polaris quality begins with our plates. Theyre constructed of rugged, heavy-duty stainless steel and pressed in designs that precisely fit a wide range of heat transfer applications. See our spec sheet for additional available plate materials. A S M E C O D E S TA M P A V A I L A B L E ( ( U S E A S M E LOGO HERE))
A sealed, compact system High temperature and pressure capability Gasket-free construction Excellent thermal efficiency Highly competitive pricing
S A F E T Y- PA I R D O U B L E W A L L P H E s Where foolproof separation of primary and secondary fluids is required, Polaris Safety-Pair PHEs deliver complete protection. For domestic hot water, dairy or other food processing, chemical manufacturing, or other critical applications, Safety-Pair PHEs from Polaris keep the fluids separated even if theres a leak. (Paired plates create an air space, allowing leaks to be seen from outside between plates. Any such leaks reach the atmosphere, either between plates or from the drain channels in the inlet/outlet areas. Media can never mix, so the risk of contamination is eliminated.) These versatile units can be assembled from almost any plate we press, so they are available in the widest possible range of shapes and sizes. F R E E - F L O W P L AT E S The Polaris Free-Flow Plate Heat Exchanger accommodates viscous fluids or those containing fibrous materials. Its wide-channeled, horizontal-ribbed pattern with no metalto-metal contact allows the free passage of particles that can block the flow in other heat exchangers. SEMI-WELDED PHEs Polaris semi-welded plate heat exchangers handle the jobs conventional plate exchangers cant touch including ammonia refrigeration and aggressive process fluids. Our semi-welded PHEs offer
I I
Laser-welded plate cassettes Welds running outside the gasket groove for corrosion protection and increased heat transfer area Superior sealing capability
I I I
Improved sealing under higher pressure Easy cleaning Compliance with 3A sanitary standards on the welded side
S A N I TA R Y H E AT E X C H A N G E R S For food, dairy, and pharmaceutical processing, sanitary heat exchangers from Polaris combine low maintenance, high efficiency, and reliable separation of fluids. Plate gaps in these exchangers are sized to reduce fouling; the main pattern creates the needed turbulence for effective heat transmission. F R E S H W AT E R D I S T I L L I N G S Y S T E M S Utilizing the heat from diesel engine jacket cooling water, the Polaris Fresh Water Distiller evaporates seawater to produce pure drinking water. Contact us for details.
Nowhere is technological leadership from Polaris better expressed than in the HVAC field. With engineering and manufacturing backed up by unsurpassed field experience, Polaris meets the demanding requirements of multiple HVAC applications.
F R E E C O O L I N G ( C H I L L E R B Y PA S S ) Structure management often requires year-round cooling to handle heat from computers, lights and other building sources. Polaris PHEs offer the ideal way to reduce hours of mechanical chiller operation. When ambient temperatures are at or below 50F, tower flow can be diverted to the Polaris heat exchanger and the chiller turned off, achieving substantial operating savings. In typical installations, retrofit is easy (no extra ductwork is needed as with air-side economizers) and the payback period is less than two years. Chiller bypass applications extend chiller life, and Polaris PHEs close approach temperatures allow more operating hours than are possible with other types.
D I S T R I C T C O O L I N G A N D H E AT I N G Polaris plate heat exchangers are often used with low-pressure steam, hot water, or chilled water in district systems. Hot or cold water is sent through insulated pipes to buildings served by the system. PHEs in the buildings serve as instantaneous heaters or coolers, also providing building loop isolation and constant pressure drop to the central plant.
W AT E R - S O U R C E H E AT P U M P S Where heat pumps rely on a water loop instead of outside air, Polaris PHEs can improve both the efficiency and the sanitation of the system. Open cooling towers served by plate heat exchangers replace less efficient, more costly closed-circuit coolers. And where the system employs well or river water, the PHE isolates the system from possible contamination.
C O O L I N G T O W E R I S O L AT I O N Its common for tower water to be contaminated with solids and atmospheric solids. If foul water is pumped through expensive chillers or heat pumps, it may damage them. Using Polaris PHEs in the system instead avoids costly maintenance and component replacement.
W A S T E H E AT R E C O V E R Y F R O M B O I L E R B L O W D O W N A N D C O N D E N S AT E Boiler blowdown, a major source of recoverable heat, makes many systems more economical. When Polaris PHEs are used to preheat incoming boiler feed water, the savings are magnified. (Returning condensate in these systems is cooled so it wont flash when drained to atmospheric pressure.)
P R E S S U R E I N T E R C E P T O R ( S TAT I C H E A D I S O L AT I O N ) In tall buildings, static head pressure can be a problem especially when glycol or water brines are used as cooling fluids. If separate loops at terminal units are employed, a Polaris plate heat exchanger can be installed to isolate the chiller or boiler from the systems high pressure. Its an arrangement that permits the use of substantially less expensive low-pressure pumps, valves, and other components.
G E O T H E R M A L H E AT I N G While geothermal energy sources can save a lot of money, the water containing the heat is usually dirty and corrosive. Low fouling tendencies make Polaris PHEs (with properly specified plate material) the ideal equipment for isolating geothermal water from the building loop.
THERMAL STORAGE Thermal storage systems maximize economy by operating refrigeration equipment in low-demand hours, chilling liquid in thermal storage tanks to provide cooling during peak demand periods. Building in a Polaris PHE makes it possible to separate glycol brine from storage water and increase system efficiency.
W A S T E H E AT R E C O V E R Y F R O M C O N D E N S E R W AT E R Water directed from a chiller condenser to a cooling tower is often hot enough to preheat water if a Polaris plate heat exchanger is installed on the line. Many users employ this method to inexpensively heat swimming pools.
Applications
H VA C Cooling Tower Isolation Free Cooling/Chiller Bypass Geothermal Heating Pressure Interceptor Thermal Storage District Heating and Cooling Water Source Heat Pumps Swimming Pool Heating Greenhouse Heating Boiler Blowdown Heat Recovery CHEMICAL PROCESSING Brine Heating and Cooling Sulfuric Acid Processing Caustic Soda Processing Vapor Condensation Salt Refining Resin Cooling AUTOMOTIVE Phosphate Solution Cooling Paint Heating Induction Heater Cooling GENERAL INDUSTRIAL Plating Solution Cooling Anodizing Cutting Oil Cooling
Represented in your area by: FOOD PROCESSING Beerwort Cooling Edible Oil Heating/Cooling Raw Milk Cooling Milk Pasteurization Hot Water Generators Tomato Sauce Processing 28 May St., Edison, NJ 08337 E-mail: sales@polarisphe.com www.polarisphe.com Phone: 737-225-3100 Fax: 732-225-9155