Professional Documents
Culture Documents
Devran 224HS Pds
Devran 224HS Pds
Generic: Catalyzed Polyamide Epoxy General Description: A high performance, multi- purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating for industrial or high performance architectural coating (HIPAC) applications. For use on properly prepared steel or masonry surfaces. Typical Uses: Ideal for structural steel, piping, tanks, and equipment in chemical, fertilizer, power plants, petroleum refineries, pulp and paper mills, water and sewage treatment plants and mining operations. Can also be used in the hard service areas of correctional facilities, schools, commercial and restaurant kitchens were a high performance architectural coating (HIPAC) is required. Special Qualifications: Performance alternate for Federal Specifications TT-C-550, TT-C-535B, MIL-C-22750F, and MIL-P23377F Type I.
Color: Off White, ready-mixed & custom colors Finish: Semi-Gloss Weight/Gallon: 12.5 lbs./gal. (1.5 kg/L) varies with color. VOC (EPA24): 1.8 lbs./gal. (212 g/L) varies with color. When thinned 5% with T-10 thinner, VOC < 250 g/L(2.08 lbs./gal) When thinned 10% with T-10 thinner, VOC < 275 g/L (2.29 lbs./gal) 224FN3501 VOC (EPA 24) (TBAC Exempt): < 100 g/L (0.83 lbs./gal.) 224FN3501 VOC (TBAC Non-Exempt): <250 g/L (2.08 lbs./gal.) Solids By Volume (ASTM D 2697-7days): 75%2% varies with color. Theoretical Coverage at 1.0 Mil (25 microns) Dry: 1203 sq. ft./gal. (29.5 m2/L). Recommended Film Thickness: 4.0-8.0 mils (100-200 microns) dry 5.3-10.7 mils (155-267 microns) wet. Systems: Please consult the appropriate system guide, the particular job specification or your ICI Paints Representative for proper systems using this product. Systems must be selected considering the particular environment involved. Minimum Dry Time (ASTM D 1640): At 6 mils (150 microns) DFT (Use of cold weather additive will decrease times noted. See cold weather applications on back page.)
Substrate Temperature Minimum Recoat Dry Hard Maximum Recoat Self 359, 389 378, 379 40F (4C) 20 Hours 42 Hours 30 Days 15 Days 10 Days 60F (16C) 8 Hours 16 Hours 30 Days 10 Days 7 Days 70F (21C) 6 Hours 9 Hours 30 Days 7 Days 5 Days 80F (27C) 3 Hours 5 Hours 30 Days 7 Days 3 Days
Advantages: Excellent corrosion protection Resists splash and spillage of solvents, alkalis, salts, moisture, oils, greases, foodstuffs and detergents Cold weather cure Use cold weather additive for application down to 25F (-4C) Surface tolerant Low VOC Self-priming on steel or masonry Abrasion resistant High build/high solids coating Limitations of Use: Exterior exposure will cause a color change, early dulling, and loss of gloss, but this does not affect protective properties. Epoxy coatings may yellow during application and cure if exposed to the combustion by-products of improperly vented fossil fuel burning heaters. Commonly finished with DEVTHANE Urethane Enamel for maximum exterior color & gloss retention. Use only products that are in compliance with local VOC regulations.
Ventilation, film thickness, humidity, thinning and other factors can influence the rate of dry. Warning: The above table provides general guidelines only. Always consult your ICI Paints Representative for appropriate recoat windows since the maximum aged recoat time of this product may be significantly shortened or lengthened by a variety of conditions, including, but not limited to humidity, surface temperature, and the use of additives or thinners. The use of accelerators or force curing may shorten the aged recoat of individual coatings. The above recoat windows may not apply if recoating with a product other than those listed above. If the maximum aged recoat window is exceeded, please consult your ICI Paints Representative for appropriate recommendations to enhance adhesion. Failure to observe these precautions may result in intercoat delamination.
Shelf Life: Over 24 months at 77F (25C) unopened Mix Ratio By Volume: 1 (base): 1 (converter)see mixing instructions. Induction: 15 minutes at 60-80F (16-27C) see mixing instructions. Pot Life: 6 hours @ 77F (25C) & 50% R.H
Adhesion: (ASTM D 4541) Excellent Salt Spray Resistance: (ASTM B 117) Excellent Direct Impact Resistance: (ASTM D 2794) Very Good Abrasion Resistance: (ASTM D 4060) Excellent Humidity Resistance: (ASTM D 4585) Excellent Exterior Exposure: (45South Lt. Industrial) Very Good (Normal, expected loss of gloss for epoxy coatings) Service Temperature Limits: 250F (121C) dry Hardness: (ASTM D 3363), 7 day cure @ 77F (25C) 3H
Chemical Resistance: (ASTM D 1308 24 hr. contact) Excellent. Resists splash and spillage of alkalis, salts, moisture, oils, greases, food stuffs, and detergents, 50% 3, 25% citric acid, 25% lactic acid, 10% sulfuric acid, crude oil, 10% hydrochloric acid, 20% tannic acid, 5% sodium chloride, 10% ammonium hydroxide, sewage, 50% ethanol, gasoline, methanol, kerosene, naphtha, xylol. All results based on testing of system comprised of two coats of DEVRAN 224HS coating at 4 mils (100 microns) DFT per coat.
DANGER! COMBUSTIBLE. HARMFUL OR FATAL IF SWALLOWED. Read label and Material Safety Data Sheet Prior to Use. See other cautions on last page. DSF2-0790
glazed concrete or concrete with laitance. Prime with PRE-PRIME 167 sealer or this coating. Galvanized Steel Remove dirt and oils by solvent cleaning or with DEVPREP 88 cleaner or other suitable cleaner followed by a thorough water rinsing. For non-immersion service, prime with DEVRAN 205 or DEVRAN 203 epoxy primers. For immersion or severe moisture condition, abrasive blasting is recommended before priming with this product or DEVRAN 201. Choice of primer depends on local VOC and air quality regulations.
Previously Painted Surfaces: Old coatings should be tested for lifting. If lifting occurs, remove the lifted coating. Otherwise scuff sand glossy areas and aged epoxy coatings. Clean aged epoxy or urethane coatings with DEVPREP 88 cleaner. Remove cracked and peeling paint. Prime bare areas with primer specified under New Surfaces. WARNING! If you scrape, sand, or remove old paint, you may release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH-approved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Information Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead.
Spreading Rate: Apply at 150-300 sq. ft. per gallon (4-7m2/L) depending on surface texture and porosity. Make allowance for any losses due to overspray or surface irregularities. Dry Time (ASTM D 1640): At 77F (25C) & 50% R.H., dries to recoat with epoxy or urethane in 6 hours and dry hard in 9 hours. Clean-up: Use T-10 Thinner, except in the South Coast Air Quality Management District use acetone, T-0 thinner or other solvent in compliance with local VOC and air quality regulations.
DANGER! COMBUSTIBLE LIQUID AND VAPOR. CORROSIVE. CAUSES EYE AND SKIN BURNS. HARMFUL OR FATAL IF SWALLOWED. ASPIRATION HAZARD - CAN ENTER LUNGS AND CAUSE DAMAGE. HARMFUL IF INHALED. MAY CAUSE CENTRAL NERVOUS SYSTEM EFFECTS, INCLUDING DIZZINESS, HEADACHE OR NAUSEA. CAUSES RESPIRATORY TRACT IRRITATION. MAY CAUSE ALLERGIC SKIN AND RESPIRATORY REACTION. OVEREXPOSURE MAY CAUSE BLOOD, LIVER, KIDNEY DAMAGE. CONTAINS CRYSTALLINE SILICA WHICH CAN CAUSE LUNG CANCER AND OTHER LUNG DAMAGE IF INHALED. USE ONLY WITH ADEQUATE VENTILATION. KEEP OUT OF THE REACH OF CHILDREN. NOTICE: Products in this series contain solvents. Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. For emergency information call (800) 545-2643. Note: These warnings encompass the product series. Prior to use, read and follow product-specific MSDS and label information. For emergency information call (800) 545-2643. For additional safety information, refer to the Material Safety Data Sheet for this product. Keep away from heat, sparks and flame. Do not smoke. Vapors may ignite. Extinguish all flames, burners, stoves, heaters and pilot lights and disconnect all electrical motors and appliances before use and until all vapors are gone. Prevent build-up of vapors by opening all windows and doors to achieve crossventilation. If sanding, wear a dust mask to avoid breathing of sanding dust. Do not breathe vapors or spray mist. Ensure fresh air entry during application and drying. Avoid contact with eyes and skin. If you experience eye watering, headaches, or dizziness, leave the area. If properly used, a respirator may offer additional protection. Obtain professional advice before using. Close container after each use. FIRST AID: For skin contact, wash thoroughly with soap and water. If any product remains, gently rub with petroleum jelly, vegetable or mineral/baby oil then wash again with soap and water. Repeat as needed. Remove contaminated clothing. For eye contact, flush immediately with plenty of water for at least 15 minutes. Get medical attention. If swallowed, get medical attention immediately. If inhalation causes discomfort, remove to fresh air. If discomfort persists or breathing difficulty occurs, get medical attention. KEEP FROM FREEZING. DS177-0306
PRECAUTIONS
SHIPPING
Flash Point: Packaging: 100F (38C) 2 gallon kit (7.570L) 1.00 gallon base 1.00 gallon converter Shipping Weight:: 10 gallon kit (37.850L) 5.00 gallon base 5.00 gallon converter 4 gallon case (base or converter) - 53 lbs. (24.0 kg 10 gallon kit - 133 lbs. (60.3 kg)
224HS (05/07) Ad Stock #68634E