Sewage Pump Amacan
Sewage Pump Amacan
Sewage Pump Amacan
1579.5/3--10 Amacan K
Applications
Sewage pumps, mixed water pumps and activated sludge
pumps in sewage treatment plants, irrigation and drainage Submersible motor pump with
pumping stations. Storm water pumps for flood protection, channel-type impeller for
water pollution control and industrial refuse tip effluents, for
pumping all pre--screened or pre--settled media not liable to
installation in discharge pipes
twist.
Operating data
Heads H up to 30 m
Capacity
-- standard programme : Q up to 1000 l/s
-- custom--made programme : Q up to 2000 l/s
Motor power P2 up to 320 kW
Product temperature: up to 40 °C
max. submersion level: 20 m
Design
Wet installed, close--coupled pump with channel--type impeller,
single--stage, single--entry, for installation in discharge pipes.
Drive
Three-phase asynchronous motor, winding acc. to IEC 38 for
400/690V supply voltage (also suitable for 380 V and 415 V
mains), enclosure type 58 to IEC 34-5/IP 68 to DIN 40050,
motor design to VDE 0530 part 1/IEC 34--1, insulation class F,
for flameproof units also VDE 0171/5.78 parts 1 and 5/
EN 50014/EN 50018, protection type EEx d IIB T3.
Bearings
-- up to motor sizes 646, 548 :
grease lubricated, maintenance--free
anti--friction bearings
-- up to motor sizes 806, 678, 4310 :
grease lubricated anti--friction bearings,
re--lubrication without dismantling the pumpset.
Amacan K 800-380 / 64 6 U G
X
Pump type
Channel type impeller Materials
DN of discharge pipe [mm] Pump casing GG-25
Impeller diameter [mm] Motor housing GG-25
Motor power P2 in kW Pump shaft C 45 N
(only correct for U motor designs) Shaft prot. sleeve 1.4021.05
Number of poles in the motor Impeller GG-25/Noridur â
U/U1/U2 = product temperature 30 °C Nuts and bolts A 4/1.4462
Motor design
X/X1/X2 = flameproof, product temperature 40°C Casing wear ring GG-25/VG 434
G = grey cast iron Cathodic corrosion protection available
Material code G1= grey cast iron with variants
G3= sea water design
Amacan K
Selection chart 50 Hz
H [m]
Q [l/s]
Q [m3/h]
Standard programme
Custom--made programme
2
Amacan K
Range chart 60 Hz
H [m]
Q [l/s]
Q [m3/h]
3
Amacan K
Cable mounted with strain relief. Especially designed lug for receiving
crane hook allows installation and
removal even when inlet chamber is
flooded.
(No need to enter the pit!)
Two- or three-channel
impeller with large
free passage
Self-centering positioning of
High operational safety due the pump in the discharge
to protected sealing chamber. column by its own weight.
Sealing ensured by an O-ring.
No additional anchoring or
Renewable casing wear ring rotational protection required.
protects casing against wear Fast installation and removal
of pump as disconnection of
pipes and cables is not
OW 380 109-00
necessary.
4
Amacan K
Table of Contents
5
Amacan K
Programme
Standard pump programme : pumpsets up to sizes 1200-540, n = 980 1/min as described in this brochure
Custom-made programme : pumpsets from size 1200-540 on, n = 980 1/min, motor power P2 > 200 kW with various drives.
Hydraulic data on request.
Scope of supply
Basic version : pump unit complete and ready for installation, 400 V / 50 Hz, supplied with10 m power cable,
without performance test
(deviations from the basic version will result in extra charges and longer delivery period).
General comments
Our pump units comply with enclosure type IP 68 in accordance with DIN 40050 and therefore include the lesser
requirements of IP 58 of IEC 34--5 valid since April 1, 1988.
During production the pumps and motors are subjected to functional tests both independently and as a unit.
Head and power rating apply only to pumped liquids with a density of ρ = 1 kg/dm3 and kinematic viscosity
ν up to 20 mm2/s.
Motor ratings P2 should have a safety factor which is adequate for a particular pumping application
(see selection example on page 33).
To facilitate transportation the electrical cabling will be supplied separately from cross--sectional area 4x50 mm2 upwards.
Applicable drawing numbers are indicated below the drawings.
Order data
-- Designation of pump unit according to ”Designation” / ”Selection of pump”
-- Capacity Q
-- Total head H (Hgeo and plant losses)
-- Liquid handled and liquid temperature
-- Voltage, frequency, starting method, length of cable
-- Accessories required -- (for discharge pipes, please indicate installation mode and relevant levels)
-- Quantity and language of operating instructions
6
Amacan K
Impeller type
Closed channel--type impeller (K impeller) Note:
for contaminated non--gaseous liquids K-impellers are trimmed to meet the exact duty point.
containing solids, not liable to twist
7
Amacan K
Types of installation
8
Amacan K
Technical data
Size Pipe dia. req. n Impeller Free passage
[mm] [1/min] no. of blades [mm]
Standard programme
700-330 700 735 3 70x92
700-330 700 980 3 70x92
700-321 700 735 2 105x115
700-321 700 980 2 105x115
700-324 700 735 3 70
700-324 700 980 3 70
800-370 800 980 3 75
800-380 800 735 3 115x95
800-381 800 735 2 145x135
800-380 800 980 3 115x95
800-381 800 980 2 145x135
1000-420 1000 735 3 126x100
1000-421 1000 735 2 140x150
1000-420 1000 980 3 126x100
1000-421 1000 980 2 140x150
1000-500 1000/1300 * 980 3 145x110
1200-540 1200 590 3 133x150
1200-540 1200/1300 * 735 3 133x150
1200-540 1300 980 3 133x150
Custom--made programme
1200-540 1400 980 3 133x150
1300-520 1300 590 3 145
1300-520 1300/1400 * 735 3 145
1300-750 1400 490 3 180
1300-750 1300/1400 590 3 180
*) depending on the motor size (see page 21)
9
Amacan K
K 700-330
K 700-324/321
K 800-370
Pump sizes K 800-380/381
K 1000-420/421
K 1000-500
K 1200-540
K 1300-520
Characteristics K 1300-750
Motor versions : 6 - pole 20 6 26 6 28 6 ... 64 6 80 6 ... 120 6 138 6 ... 200 6 260 6 ... 320 6
U = non-flameproof 8 - pole 10 8; 17 8 21 8 25 8 ... 54 8 67 8 ... 107 8 126 8 ... 180 8 225 8 ... 280 8
X = flameproof 10 - pole 43 10 ... 84 10 107 10 ... 170 10 215 10 ... 270 10
12 - pole 132 12 ... 200 12
Typical sectional drawing / motor p.14 p.15 p.16 p.17 ----
size DKN 161; 181 225 280 315 355
Shaft sealing
mechanical
Explosion
0171/5.78 ---- - `
EN50014/50018
protection
(Ex) dll G3
VDE 0171/1.69 - ----
Insulation class F
-
Windings for 400V/50 Hz mains
400 V delta ; 690 V star
(suitable for 380 ... 415 V)
230 V 1 with special winding ----
500 V 1 with special winding star connected
Windings for
elektrical
mains 690 V
voltage 1 with standard winding star connected
other voltages `
10
Amacan K
permissible
submersion X 20 m
level
Pumped U 30 °C
liquid
temperature X 40 °C
U automatic on/off when permissible winding temp. has been reached (control circuit)
temperature X 2 separate control circuits -- automatic on/off control when permissible winding temp.
control of has been reached (control circuit)
Monitoring page 13
the winding -- trip control when the flameproof temperature limit has
been reached (limitation circuit)
Temp. control of pump-side
anti--friction bearings (PT 100) ---- ` -
Moisture electrode in the motor
housing
` -
Float switch in the leakage
chamber to monitor mech. seal ---- -
11
Amacan K
Materials
Material combinations G G1 G3 1)
(Sea water version)
Part No. Designation Materials
12
Amacan K
21 22 10 11 Motor version ”U” and ”W” Motor version ”X” and ”Y”
(non-flameproof) (flameproof)
Ill 1
1) For inverter operation with flameproof requirements, PTB--approved tripping devices are required, e.g. make Siemens type
3UN6 with manual reset.
2) KSB tripping device available with both functions
20 21 = identity of conductor
Bi-Metall / PTC = temperature sensor in the winding
13
Amacan K
Sectional drawing
typical for sizes < 4 kW to 30 kW
571
914.26
920.26
550.26
529
322
932.01
421.01
811/81-59 932.03
818 321.02
914.02
412.02
834 441
914.04 412.03
412.07 330
81-17 932.02
900.28 903
411.03
81-56
903.15
81-44.28
81-18
99-17
902.01
920.01
412.04
113
433.01
433.02
412.20
Part No. Part Designation Part No. Part Designation Part No. Part Designation
101 Pump casing 421 Lip seal 818 Rotor
113 Intermediate casing 433 Mechanical seal 834 Cable duct
230 Impeller 502 Casing wear ring 900 Bolt
260 Impeller hub cap 529 Bearing sleeve 902 Stud
321 Radial ball bearing 550 Disc 903 Screw plug
322 Radial roller bearing 571 Lug 914 Socket head cap screw
330 Bearing bracket 81-17 Cable crimp 920 Nut
411 Joint ring 81-18 Cable socket 932 Circlip
412 O-ring 81-56 Moisture protection of motor 99-17 Desiccant
14
Amacan K
550.25 901.25
550.25
920.25
81-97.2
68-3.2 59-71 571
901.26
914.01
500.04
322 412.01
932.01 812
421.01
500.01
81-22
80-1
81-56 818
81-45 360
411.26
321
901.01
99-17 550.02
914.02 550.01
412.09 932.02
412.02
914.06 433.01
903.03 433.02
411.03
421.02
412.05
500.02
903.04
350 411.04
903.5
411.05
412.04
902.01
920.01
113
411.06
OW 380 103-00
550.23 931.01
412.06 901.21 940.03 260 502 230 101 412.20
Part No. Part Designation Part No. Part Designation Part No. Part Designation Part No. Part Designation
101 Pump casing 421 Lip seal 81-56 Moisture protection of motor 931 Lock washer
113 Intermediate casing 433 Mechanical seal 81-97 Cable protector 932 Circlip
230 Impeller 500 Ring 812 Motor casing cover 940 Key
260 Impeller hub cap 502 Casing wear ring 818 Rotor 99-17 Desiccant
321 Radial ball bearing 550 Disc 834 Cable duct
322 Radial roller bearing 571 Lug 901 Hexagon bolt
350 Bearing housing 68-3 Cover plate 902 Stud
360 Bearing cover 80-1 Semi-finished motor 903 Screw plug
411 Joint ring 81-22 Terminal box cover 914 Socket head cap screw
412 O-ring 81-45 Float switch 920 Nut
15
Amacan K
550.25 A -- A 901.25
550.25
920.25
81-97.2
68-32
59-71
571
901.26
812
914.01 903.01
411.01
412.01 636.01
500.04
322
500.01
932.01
520.01
421.01 80-1
818
360
500.03
412.09 647
81-22
320
901.01
421.03 550.02
932.02
550.01
500.05
500.02
81-56
350
914.06
903.03
412.02 411.03
914.02 636.02
99-17 903.02
411.02
412.03 903.04
411.04
81-45
421.02
411.26
903.05
411.05
902.01
920.01
412.04
412.05
113
411.06
433.01
433.02
OW 380 104-00
Part No. Part Designation Part No. Part Designation Part No. Part Designation Part No. Part Designation
101 Pump casing 421 Lip seal 80-1 Semi-finished motor 914
9 S
Socket head cap
p
113 Intermediate casing 433 Mechanical seal 81-22 Terminal box cover screw
230 Impeller 500 Ring 81-45 Float switch 920 Nut
260 Impeller hub cap 502 Casing wear ring 81-56 Moisture protection of motor 931 Lock washer
320 Anti--friction bearing 520 Sleeve 81-97 Cable protector 932 Circlip
322 Radial roller bearing 550 Disc 812 Motor casing cover 940 Key
350 Bearing housing 571 Lug 818 Rotor 99-17 Desiccant
360 Bearing cover 636 Grease nipple 901 Hexagon bolt
411 Joint ring 647 Grease regulator 902 Stud
412 O-ring 68-3 Cover plate 903 Screw plug
16
Amacan K
571
901.26
901.04 500.04
322
932.01
903.01
411.01
636.01
914.01 500.01
421.01
412.01 520.01
812 360
500.03
80-1
421.03
818 647
320
834.01 500.05
834.03 550.01
932.02
412.12
901.01
69-6 550.02
500.02
81-56
421.02
411.26 412.03
902.03 350
920.03 903.03
412.02 411.03
903.02
99-17 411.02
636.02
914.02 903.04
411.04
903.05
411.05 916.02
902.01 914.03
920.01
411.06
81-45
412.04
916.03
412.05
113
433.01
433.02 OW 380 105-00
Part No. Part Designation Part No. Part Designation Part No. Part Designation Part No. Part Designation
101 Pump casing 421 Lip seal 80-1 Semi-finished motor 916 Plug
113 Intermediate casing 433 Mechanical seal 81-45 Float switch 920 Nut
230 Impeller 500 Ring 81-56 Moisture protection of motor 931 Lock washer
260 Impeller hub cap 502 Casing wear ring 812 Motor casing cover 932 Circlip
320 Anti--friction bearing 520 Sleeve 818 Rotor 940 Key
322 Radial roller bearing 550 Disc 834 Cable duct 99-17 Desiccant
350 Bearing housing 571 Lug 901 Hexagon bolt
360 Bearing cover 636 Grease nipple 902 Stud
411 Joint ring 647 Grease regulator 903 Screw plug
412 O-ring 69-6 Temperature sensor 914 Socket head cap screw
17
Amacan K
433.01
551.01
932.03
433.02
524
562.13
412.17
OW 309 124-00
figure 1
18
Amacan K
433.01
550.03
932.03
500.06
914.07
433.02
524
412.17
940.13
OW 309 110-00
figure 2
19
Amacan K
OW 380 111-00
OW 380 085-00
d7
b20
20
Amacan K
Pump and support ring all dim. in mm, standard programme up to 1200-540/10710 2, custom--made progr. from 1200-540/2606 upwards
21
Amacan K
OW 380 119-00
OW 380 117-00
b = to suit b = to suit
22
Amacan K
Pump sizes D pipe dia. A DN2 min DN2 max H1 min H3 min H1,H3 max H2 min H0 max
700-330 711 700 650 300 600 1900 2570 670 7820
700-324/321 711 700 650 300 600 1900 2570 670 7820
800-370 813 800 700 400 700 2080 2850 10000 770 7580
800-380/381 813 800 700 400 700 2250 3020 770 7410
1000-420/421 1016 1000 810 600 900 2520 3490 (discharge 925 7040
pipes longer
1000-500 1016 1000 810 600 900 2730 3700 than 925 6830
1320 1300 960 1000 1300 3280 4660 10,000 mm 1130 6080
on request)
1200-540 1220 1200 910 900 1200 2930 4200 1080 6480
1320 1300 960 1000 1300 3280 4660 1130 6080
1420 1400 1010 1100 1400 3640 5000 1180 5660
1300-520 1320 1300 960 1000 1300 3110 4500 1130 6240
1420 1400 1010 1100 1400 3380 4800 1180 5920
1300-750 1320 1300 960 1000 1300 3420 4800 1130 5930
Pump sizes D H4 M1 M2 M3 M4 N1 N2 N3 N4
700-330 711 500 800 1150 1160 1080 1160 910 455 695
700-324/321 711 500 800 1150 1160 1080 1160 910 455 695
800-370 813 550 900 1250 1260 1250 1260 1010 505 745
800-380/381 813 550 900 1250 1260 1250 1260 1010 505 745
1000-420/421 1016 650 1120 1460 1460 1450 1460 1210 605 855
1000-500 1016 650 1120 1460 1460 1450 1460 1210 605 855
1320 1000 1450 1760 1760 1700 1900 1510 755 1005
1200-540 1220 930 1350 1670 1670 1600 1800 1410 710 960
1320 1000 1450 1760 1760 1700 1900 1510 755 1005
1420 1050 1550 1870 1870 1900 2040 1610 810 1060
1300-520 1320 1000 1450 1760 1760 1700 1900 1510 755 1005
1420 1050 1550 1870 1870 1900 2040 1610 810 1060
1300-750 1320 1000 1450 1760 1760 1700 1900 1510 755 1005
23
Amacan K
Installation plan
Installation example Installation mode BU
hü
ha
H geo
D View Y
t4
Minimum
water level
d7
Y
t1
t2
t3
Section A -- A
100
350
e1
s 1/2 min
Foundation holes
s 1 min
p2
Recommended
inflow direction
=100 p2
0-45° =p1
s 1 min
View X
(without pump)
A Foundation holes
OW 380 120--00
Support plate
A -- discharge pipes
24
Amacan K
hü [m]
Amacan K 1300-750
Diagram for minimum
water level t1
700-- 324/321
25
Amacan K
Installation plan
Installation example Installation mode CU
DN2 can be chosen with regard to the desired outlet speed.
See table DN2min/DN2max and head loss diagram.
X
A
t5
DN 2
a
Vent pipe
H geo
t4
D
View Y
Minimum
water level
d7
Y
t1
t2
t3
e1
Section A -- A
300
250
s 1/2 min
200
View X
s 1 min
0-45°
a3
p2
p1
a1
26
Amacan K
HV ges includes:
-- elbow
-- disch. pipe length = 5xDN2
-- check valve
-- outlet loss v2/2g
Q [m3/s]
OW 380 110--00
700-- 324/321
27
Amacan K
Installation plan
Installation example Installation mode DU DN2 can be chosen with regard to the desired outlet speed.
See table DN2min/DN2max and head loss diagram.
-- not pressure sealed X
H4
DN 2
a
t6
A
t7
A View Y
D
t4
Vent pipe
d7
Minimum
water level
Y
t1
t2
t3
Section A -- A
300
250
s 1/2 min
200
s 1 min
Recommended
Foundation holes View X
inflow direction (without pump)
0-45°
s 1 min
e1 Foundation
p2
p1
a1 holes
Support plate
-- discharge pipe
200 a2 200
OW 380 122-00
Pump sizes D*) DN2 min DN2 max a a1 a2 t6 min t6 max H4 t7 max
700-330 711 300 600 650 860 610 820 8250 500
700-324/321 711 300 600 650 860 610 820 8250 500
800-370 813 400 700 700 960 710 870 8020 550
800-380/381 813 400 700 700 960 710 870 7850 550
10000
1000-420/421 1016 600 900 810 1160 910 1075 7585 650
1000-500 1016 600 900 810 1160 910 1075 7375 650 ((discharge
g
pipes
1320 1000 1300 960 1460 1210 1480 6820 1000 longer than
1200-540 1220 900 1200 910 1360 1110 1410 7210 930 10,000
, mm
1320 1000 1300 960 1460 1210 1480 6820 1000 on request)
1300-520 1320 1000 1300 960 1460 1210 1460 6260 1000
1420 1100 1400 1010 1560 1310 1530 6110 1050
1300-750 1320 1000 1300 960 1460 1210 1480 6090 1000
*) from size 1000-500 onwards, D depends on motor size, see page 21
hV Kr [m]
Except for hV Kr
all losses must be calculated
with a view to plant conditions
Q [m3/s]
OW 380 110--00
700-- 324/321
29
Amacan K
Pump with suspension wire and tensioning device in discharge pipe turnbuckle
Part list
59-47
59-24
Clamp
59-17.2
Spacer
OW 380 091-00
Control cable
Power supply cable
30
Amacan K
Top view
Section A -- A
3
OW 380 836-00 2 5 4 1 5
31
Amacan K
Top view
View X
X
2
A 3
A
Section A -- A
OW 380 861-00
1 5 6 8 4 7
32
Amacan K
A
section de passage
4 : 408 / 378
Q [ l/s ] 3 398 / 344
2 : 384 / 317
H [m] 1 : 367 / 295
H [m] H [ft]
Förderhöhe
Head
Impeller Hauteur
diameter
With available QH data,
the impeller diam. D2A is
approx. 400 mm and thus
Pduty can be found.
B Pduty
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
P2 min
C
(Flameproof) kW A A mm2 mm kg
Minimum
24 .../266 U 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 730
motor power U 28 .../286 U 60.0 250 0.78 2x4x4 16.6-18.7 A 780
P2 min
tmax = 30 °C - 37 .../376 U 77.0 335 0.78 2x4x6 17.8-19.8 A 870
45 .../456 U 92.0 460 0.79 2x4x10 21.7-23.7 A 930
24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 730
X 28 .../376 X 61.0 335 0.75 2x4x4 16.6-18.7 A 870
tmax = 40 °C 37 .../456 X 77.0 460 0.77 2x4x6 17.8-19.8 A 930
45 .../646 X 106.0 600 0.69 2x4x10 21.7-23.7 A 1030
Motor size
Selected: Motor version ”U”, (non--flameproof), motor with 37.0 kW, 6--pole
Designation of complete pump set: : Amacan K 800--381 / 376 U G
For further data refer to the tables on pages 34-55 and motor documentation Amarex KRT Rh.-Nr. 2553.53/. . .-90
Note :
Impellers are trimmed to the operating point.
The QH data should be clearly stated at the time of ordering, in order to define the exact impeller diameter.
33
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-321/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 18 .../206 U 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 30 °C 24 .../266 U 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
X 18 .../206 X 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 40 °C 24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
34
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-321/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 10 .../108 U 22.5 65 0.79 1x(12x2.5) 22.7--24.7 -- 410
tmax = 30 °C 16 .../178 U 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
X 10 .../108 X 22.5 65 0.79 1x(12x2.5) 22.7--24.7 -- 410
tmax = 40 °C 16 .../178 X 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
35
Amacan K
70 x 70 mm
Nr. : D2A / D2I freier Durchgang
[mm] free passage
3 : 324 / 324 section de passage
H [m] 2 : 309 / 280 H [ft]
1 : 290 / 234
Förderhöhe
Head
Hauteur
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Courbes selon
ISO 9906/A.
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-324/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 18 .../206 U 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 30 °C 24 .../266 U 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
X 18 .../206 X 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 40 °C 24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
36
Amacan K
70 x 70 mm
freier Durchgang
Nr. : D2A / D2I free passage
[mm] section de passage
H [m] 3 : 324 / 324 H [ft]
2 : 309 / 280
Förderhöhe 1 : 290 / 234
Head
Hauteur
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-324/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 10 .../108 U 22.5 65 0.79 1x(12x2.5) 22.7-24.7 -- 410
tmax = 30 °C 16 .../178 U 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
X 10 .../108 X 22.5 65 0.79 1x(12x2.5) 22.7-24.7 -- 410
tmax = 40 °C 16 .../178 X 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
37
Amacan K
70 x 92 mm
Nr. : D2A / D2I freier Durchgang
[mm] free passage
section de passage
4 : 326 / 326
H [m] 3 : 300 / 292 H [ft]
Förderhöhe
2 : 287 / 245
Head 1 : 270 / 214
Hauteur
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Förderstrom/Rate of Flow/Débit Courbes selon
ISO 9906/A.
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-330/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 18 .../206 U 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 30 °C 24 .../266 U 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
X 18 .../206 X 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 430
tmax = 40 °C 24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 470
38
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
Förderstrom/Rate of Flow/Débit
ISO 9906/A.
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 700-330/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 10 .../108 U 22.5 65 0.79 1x(12x2.5) 22.7-24.7 -- 410
tmax = 30 °C 16 .../178 U 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
X 10 .../108 X 22.5 65 0.79 1x(12x2.5) 22.7-24.7 -- 410
tmax = 40 °C 16 .../178 X 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 435
39
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 800-370/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
18 .../206 U 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 505
U 24 .../266 U 48,.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 565
tmax = 30 °C 28 .../286 U 60.0 250 0.78 2x4x4 16.6--18.7 A 710
37 .../376 U 77.0 335 0.78 2x4x6 17.8--19.8 A 780
18 .../206 X 35.5 160 0.85 1x(7x4+5x1.5) 26.9--28.8 -- 505
X 24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 565
tmax = 40 °C 28 .../376 X 61.0 335 0.75 2x4x4 16.6--18.7 A 780
37 .../456 X 77.0 460 0.77 2x4x6 17.8--19.8 A 860
40
Amacan K
H [m] H [ft]
Förderhöhe
Head
Hauteur
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 800-380/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
28 .../286 U 60.0 250 0.78 2x4x4 16.6--18.7 A 780
U 37 .../376 U 77.0 335 0.78 2x4x6 17.8--19.8 A 870
tmax = 30 °C 45 .../456 U 92.0 460 0.79 2x4x10 21.7--23.7 A 930
64 .../646 U 139.0 600 0.75 2x4x16 27.1--30.1 A 1030
28 .../376 X 61.0 335 0.75 2x4x4 16.6--18.7 A 870
X
37 .../456 X 77.0 460 0.77 2x4x6 17.8--19.8 A 930
tmax = 40 °C
45 .../646 X 106.0 600 0.69 2x4x10 21.7--23.7 A 1030
41
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 800-380/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
16 .../178 U 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 630
U
20 .../218 U 44.0 150 0.75 1x(7x10+5x1.5) 29.5--32.9 -- 700
tmax = 30 °C
25 .../258 U1 57.0 230 0.73 2x4x4 16.9-18.7 A 870
16 .../178 X 36.0 115 0.79 1x(7x4+5x1.5) 26.9--28.8 -- 630
X
20 .../218 X 44.0 150 0.75 1x(7x10+5x1.5) 29.5--32.9 -- 700
tmax = 40 °C
25 .../338 X1 60.0 300 0.69 2x4x4 16.6-18.7 A 930
42
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 800-381/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
24 .../266 U 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 730
U 28 .../286 U 60.0 250 0.78 2x4x4 16.6-18.7 A 780
tmax = 30 °C 37 .../376 U 77.0 335 0.78 2x4x6 17.8-19.8 A 870
45 .../456 U 92.0 460 0.79 2x4x10 21.7-23.7 A 930
24 .../266 X 48.5 225 0.84 1x(7x10+5x1.5) 29.5--32.9 -- 730
X 28 .../376 X 61.0 335 0.75 2x4x4 16.6-18.7 A 870
tmax = 40 °C 37 .../456 X 77.0 460 0.77 2x4x6 17.8-19.8 A 930
45 .../646 X 106.0 600 0.69 2x4x10 21.7-23.7 A 1030
43
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 800-381/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable
dia.
(Flameproof) kW A A mm2 mm kg
U 16 .../178 U 36.0 115 0.79 1x(7x4+5x1.5) 26.9-28.8 -- 630
tmax = 30 °C 20 .../218 U 44.0 150 0.75 1x(7x10+5x1.5) 29.5-32.9 -- 700
X 16 .../178 X 36.0 115 0.79 1x(7x4+5x1.5) 26.9-28.8 -- 630
tmax = 40 °C 20 .../218 X 44.0 150 0.75 1x(7x10+5x1.5) 29.5-32.9 -- 700
44
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1000-420/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
45 .../456 U1 92.0 460 0.79 2x4x10 21.7--23.7 A 1050
U 64 .../646 U1 139.0 600 0.74 2x4x16 27.1--30.1 A 1200
tmax = 30 °C 80 .../806 U1 158.0 740 0.81 2x4x25 32.8--35.8 A 1400
102 .../1026 U 200.0 1140 0.82 2x4x25 32.8--35.8 A 1550
45 .../646 X1 105.0 600 0.69 2x4x10 21.7--23.7 A 1200
X 64 .../806 X1 131.0 740 0.77 2x4x16 27.1--30.1 A 1400
tmax = 40 °C 80 .../1026 X 158.0 1140 0.80 2x4x25 32.8--35.8 A 1550
102 .../1206 X 200.0 1450 0.79 2x4x25 32.8--35.8 A 1650
45
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
Förderstrom/Rate of Flow/Débit ISO 9906/A.
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1000-420/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
25 .../258 U2 57.0 230 0.73 2x4x4 16.6--18.7 A 1000
U
33 .../338 U2 72.0 300 0.75 2x4x6 17.8--19.8 A 1050
tmax = 30 °C
43 .../438 U 100.0 460 0.70 2x4x10 21.7--23.7 A 1150
25 .../338 X2 59.0 300 0.70 2x4x4 16.6--18.7 A 1050
X
33 .../438 X 85.0 460 0.64 2x4x10 21.7--23.7 A 1150
tmax = 40 °C
43 .../548 X 105.0 560 0.66 2x4x10 21.7--23.7 A 1200
46
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1000-421/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
37 .../376 U1 77.0 335 0.78 2x4x6 17.8--19.8 A 1010
U 45 .../456 U1 92.0 460 0.79 2x4x10 21.7--23.7 A 1050
tmax = 30 °C 64 .../646 U1 139.0 600 0.74 2x4x16 27.1--30.1 A 1200
80 .../806 U1 158.0 740 0.81 2x4x25 32.8--35.8 A 1400
37 .../456 X1 77.0 460 0.77 2x4x6 17.8--19.8 A 1050
X
45 .../646 X1 105.0 600 0.69 2x4x10 21.7--23.7 A 1200
tmax = 40 °C
64 .../806 X1 131.0 740 0.77 2x4x16 27.1--30.1 A 1400
47
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1000-421/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
25 .../258 U2 57.0 230 0.73 2x4x4 16.6--18.7 A 1000
U
33 .../338 U2 72.0 300 0.75 2x4x6 17.8--19.8 A 1050
tmax = 30 °C
43 .../438 U 100.0 460 0.70 2x4x10 21.7--23.7 A 1150
19 .../258 X2 46.0 230 0.68 2x4x4 16.6--18.7 A 1000
X 25 .../338 X2 59.0 300 0.70 2x4x4 16.6--18.7 A 1050
tmax = 40 °C 33 .../438 X 85.0 460 0.64 2x4x10 21.7--23.7 A 1150
43 .../548 X 105.0 560 0.66 2x4x10 21.7--23.7 A 1200
48
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1000-500/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
80 .../806 U1 158.0 740 0.81 2x4x25 32.8--35.8 A 1470
102 .../1026 U 200.0 1140 0.82 2x4x25 32.8--35.8 A 1630
U 120 .../1206 U 230.0 1450 0.82 2x4x35 36.9--39.9 A 1750
tmax = 30 °C 138 .../1386 U 245.0 1750 0.87 2x4x35 36.9--39.9 B 2050
165 .../1656 U 285.0 1670 0.89 2x4x50 42.9--45.9 B 2200
200 .../2006 U 345.0 2400 0.91 2x3x70/35 48.4--51.4 B 2350
80 .../1026 X 158.0 1140 0.80 2x4x25 32.8--35.8 A 1630
102 .../1206 X 200.0 1450 0.80 2x4x25 32.8--35.8 A 1750
X
120 .../1386 X 215.0 1750 0.87 2x4x35 36.9--39.9 B 2050
tmax = 40 °C
138 .../1656 X 240.0 1670 0.89 2x4x35 36.9--39.9 B 2200
165 .../2006 X 258.0 2400 0.90 2x4x50 42.9--45.9 B 2350
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s
Warranty acc. to ISO 9906/A
1) further starting modes on request
2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
49
Amacan K
Amacan K 1200-540 (applies to Amacan k 1300-540 and 1400-540, too) 980 1/min
Laufradform
Impeller type
Forme de roue
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1200-540/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
165 .../1656 U 285.0 1670 0.89 2x4x50 42.9--45.9 B 3000
U 200 .../2006 U 345.0 2400 0.91 2x3x70/35 48.4--51.4 B 3150
tmax = 30 °C 260 .../2606 U 450.0 1920 0.89 2x3x95/50 55.0--59.0 B 3550
320 .../3206 U 590.0 3700 0.83 4x4x50 42.9--45.9 B 3750
165 .../2006 X 285.0 2400 0.90 2x4x50 42.9--45.9 B 3150
X
200 .../2606 X 345.0 1920 0.88 2x3x70/35 48.4--51.4 B 3550
tmax = 40 °C
260 .../3206 X 470.0 3700 0.84 4x4x35 36.9--39.9 B 3750
50
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1200-540/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
84 .../848 U 177.0 680 0.77 2x4x25 32.8--35.8 A 2400
U 107 .../1078 U2 225.0 1000 0.76 2x4x35 36.9--39.9 A 2500
tmax = 30 °C 126 .../1268 U2 240.0 1220 0.83 2x4x35 36.9--39.9 B 2910
150 .../1508 U2 285.0 1400 0.82 2x4x50 42.9--45.9 B 3100
84 .../1078 X2 199.0 1000 0.67 2x4x25 32.8--35.8 A 2500
X 107 .../1268 X2 205 1220 0.82 2x4x35 36.9--39.9 B 2910
tmax = 40 °C 126 .../1508 X2 250.0 1400 0.80 2x4x50 42.9--45.9 B 3100
150 .../1808 X2 275.0 1700 0.85 2x4x50 42.9--45.9 B 3210
51
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1200-540/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
43 .../4310 U1 99.0 380 0.68 2x4x10 21.7--23.7 A 2250
U 54 .../5410 U2 121.0 420 0.71 2x4x16 27.1--30.1 A 2350
tmax = 30 °C 67 .../6710 U2 149.0 540 0.71 2x4x16 27.1--30.1 A 2450
84 .../8410 U2 189.0 680 0.70 2x4x25 32.8--35.8 A 2550
43 .../5410 X2 102.0 420 0.67 2x4x10 21.7--23.7 A 2350
X 54 .../6710 X2 125.0 540 0.68 2x4x16 27.1--30.1 A 2450
tmax = 40 °C 67 .../8410 X2 159.0 680 0.66 2x4x25 32.8--35.8 A 2550
84 .../10710 X2 185.0 980 0.70 2x4x25 32.8--35.8 B 2900
52
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1300-520/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
126 .../1268 U1 235 1220 0.84 2x4x35 36.9--39.9 B 3050
U 150 .../1508 U1 290 1400 0.82 2x4x50 42.9--45.9 B 3200
tmax = 30 °C 180 .../1808 U1 335 1700 0.84 2x3x70/35 48.4--51.4 B 3350
225 .../2258 U1 425 2650 0.83 2x3x95/50 55.0--59.0 B 3900
126 .../1508 X1 245 1400 0.81 2x4x35 36.9--39.9 B 3200
X 150 .../1808 X1 275 1700 0.85 2x4x50 42.9--45.9 B 3350
tmax = 40 °C 180 .../2258 X1 355 2650 0.80 2x3x70/35 48.4--51.4 B 3900
225 .../2808 X1 445 3420 0.78 2x3x95/50 55.0--59.0 B 4250
53
Amacan K
P [kW] P [hp]
Leistungsbedarf
Power Input
Puiss. hyd. abs.
Kennlinien nach
ISO 9906/A
Curves as per
ISO 9906/A.
Courbes selon
ISO 9906/A.
Förderstrom/Rate of Flow/Débit
Motor Motor Amacan K Code Irated Istarting 1) cos j Electric cables NSSHöu-J Weight
design rating 1300-520/... Nr. d.o.l. Power supply cable Control
U or X P2 Cross-section Outside cable 2)
dia.
(Flameproof) kW A A mm2 mm kg
67 .../6710 U1 149 540 0.71 2x4x16 27.1--30.1 A 2650
U
84 .../8410 U1 189 680 0.70 2x4x25 32.8--35.8 A 2750
tmax = 30 °C
107 .../10710 U1 220 980 0.75 2x4x35 36.9--39.9 B 3000
67 .../8410 X2 159 680 0.66 2x4x25 32.8--35.8 A 2750
X
84 .../10710 X2 185 980 0.70 2x4x25 36.9--39.9 B 3000
tmax = 40 °C
107 .../12610 X2 205 1070 0.82 2x4x35 36.9--39.9 B 3200
54
Amacan K
55
Amacan K
L= mm
10/97
KSB Aktiengesellschaft
P.O. Box 200743 · 06008 Halle (Saale) · Turmstraße 92 · 06110 Halle (Germany)