Significance of Protection System
Significance of Protection System
protection systems
T.ANIL KUMAR
Sr.Asst.Engineer
Regional Lab
Power Grid Corporation of India Ltd.
Ph.No-94906111092
What is protection?
The
Electrical
WHAT IS A
PROTECTION ?
Why
it
is
required?
Humans
need protection
from
external disease , sun
and whether. All the internal parts of the human
beings are protected naturally. Heart and lungs are
protected by ribs bones from external impact. Brain
is protected by skull.Eyes are protected by eyelids
and by closing eyes. We need cloths to protect us
from external environment conditions.
Objective of Protection
Protect persons and equipment in
the surrounding of the power system
Protect
system
Separate
lines 85%
12%
Transformer/
Generator 3%
Fault statistics
Single
Primary
Relaying
Generator Protection
Circuit Breaker
Low voltage
Protection
Power Trans.
Protection
High voltage
Protection
Transmission
line Prot.
High voltage
Protection
What is a Relay?
A
Output
A Simple Relay
Solenoid
Input
Armature
ELEMENTS OF PROTECTION
Bus
Trip Ckt
CB
Current
DC SOURCE
Relay
Voltage
Feeder
CT
CV
T
FUNCTIONAL CHARACTERISTICS
OF PROTECTIVE RELAYING
1.
2.
3.
4.
5.
SENSITIVITY
SELECTIVITY
SPEED
REPEATABILITY
ECONOMY
12
Basis of Classifications
Quantity
Function:
Construction:
Numerical
Electromagnetic, Static or
Armature
Moving Coil
Induction
Thermal
Motor-Operated
Mechanical
Static
Numerical
Thermal Relays
Thermal
Mechanical relays
Various relays responding to:
Pressure
Liquid levels
Fluid flow etc..
Static Relays
Relays making use of various electronic
devices / phenomena such as:
1. Electronic Relays
2. Transductor (magnetic amplifier) relays
3. Rectifier bridge relays
4. Transistor Relays
5. Hall effect relays
6. Gause effect relays
Static Relays(Contd)
Numerical Relays
All input signals are converted to digital
quantities after conditioning using ADCs
All measurements are performed by DSPs
numerically
Relays are highly accurate and immune to drift
and calibration problems.
Application based
classifications
Distance relays
Basically measure impedance with
voltage and current inputs
A+B
No Trip
A+B
No Trip
A+B
Trip
A+B
Trip
Differential Protection
: DTH31,RADSB,RADHA
Ground Fault Protection
: CAG14, RADHD
Over Current Protection
: CDD,RXIG
Over Load Protection
: VTU,RXEG
Over Fluxing Protection
: GTT,RATUB
Buchholz Relay (OLTC & Main Tank)
Pressure Relief Device
Oil and Winding temp alarms and trips
Oil Level Monitoring (MOLG)
Differential Relays
I1
I2
i1
i2
id=(i1-i2)
TRANSFORMER DIFFERENTIAL
RELAY
For
64
OTHER TRANSFORMER
PROTECTION
AUTORECLOSE PHILOSOPHY
NEED FOR AUTO RECLOSE
1. REDUCING OUTAGE TIME
2. IMPROVED RELIABILITY
3. RESTORATION OF NETWORK STABILITY AND
SYNCHRONISM
4. REDUCTION OF OPERATING COST BECAUSE
OF ABOVE FACTORS
ANALYSIS OF FAULTS
1. TRANSIENT FAULTS
2. SEMI PERMANENT FAULTS
3. PERMANENT FAULTS
SYSTEM SUPERVISION.