Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

2016 - 01 - 22 - Principle Process Layout PT - Conveyor

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 2

22.01.

2016

Pack Tracking Conveyor


® by HERMOS

General Electrical Equipment Layout

+STI +INS +PRT +PB +CON


Pre-Stopper / Itemiser Insertion Station Bundle Print Station Peribox Tracking Conveyor
=CON Control Cabinet
+GH001 for Conveyor belt
=CON Control Panel
+GH002 for Conveyor belt
=V101.INS Valve =V101.PRT Valve =CON Valve Terminal
VT-1Y1 for Insertion +VT-1Y1 for Stopper +VT for Conveyor
=V101.STI Valve =V101.INS Valve Position =V101.PRT Valve Position
+VT-1Y1 for Stopper -1B1 Feedback HP -1B1 Feedback HP
=V101.STI Valve Position =V101.INS Valve Position =V101.PRT Valve Position =EI001.CON Status Indication
-1B1 Feedback HP -1B2 Feedback OP -1B2 Feedback OP -1H1 LED 1
=V101.STI Valve Position =GOS101.INS Bundle Presence =GOS201.PRT Bundle Presence =XS101.PB Peribox Trigger =EI001.CON Status Indication
-1B2 Feedback OP -1B1 INS Station -1B1 Sensor Section 1 -1S1 Command -1H2 LED 2
=GOS201.STI Bundle Presence =GOS201.INS Bundle Presence =GOS202.PRT Bundle Presence =XS102.PB Bundle Camera =EI001.CON Status Indication
-1B1 Sensor -1B1 Sensor -1B1 Apply Position -1S1 Command -1H3 LED 3

=XS101.PRT Printer Trigger +REJ =M101.CON Motor Drive / VSD


-X1 Command -1M1 for Conveyor belt
Bundle Reject Station
=XS101.PRT Apply Label =M101.CON Motor Drive
-X2 Command -1K1 Start
=V101.REJ Valve
=XS101.PRT Label Applied +VT-1Y1 =M101.CON Motor Drive
for Bundle Reject
-X7 Feedback -1X1 Control
=V101.REJ Valve Position
=XS101.PRT Printer Ready -1B1 =GOS201.CON Queue Sensor
Feedback HP
-X7 Feedback -1B1 Downstream Jam
=V101.REJ Valve Position
=QR101.PRT Bundle Label -1B2 Feedback OP =XS101.CON Interface
-1A1 Checker -X1 =CON “ready”
=GOS201.REJ Bundle Presence
=QR101.PRT Label Checker -1B1 Reject Position =XS102.CON Interface
-1S1 Trigger Signal =XS101.REJ Bundle Reject
-X1 =CON “release”
=QR101.PRT Label Checker -1S1 Command =ZS101.CON Safety Housing
-1S2 No Read Feedback -1S1 ... -1S? not open

© Copyright Hermos AG, Mistelgau, 2016


22.01.2016

Pack Tracking Conveyor


® by HERMOS

General Automation Layout

Panel PC
CP6606-0001-0020

(*1) TwinCAT I/O


- EK1100 EtherCAT Coupler
separated 24VDC power supply for K-Bus and power terminals
- 4x EL1018 Digital Input Terminal
RJ45 Patch Panel USB Hub - 2x EL2808 Digital Output Terminal
for DIN rail mount for DIN rail mount - EL9400 Power Supply Terminal 24VDC safety power
- EL2808 Digital Output Terminal for Safety Outputs
- EL9011 End Cap

Movimot Inverter
(*1) TwinCAT I/O EtherCAT communication
via EtherCAT communication

© Copyright Hermos AG, Mistelgau, 2016