How To Setup Biotrans ?
How To Setup Biotrans ?
How To Setup Biotrans ?
1
Warning !!!
Don’t use pressure bag when you are in
priming position.
Please do not put the white cap after
zeroing.
2
Zeroing
Close flow from patient to transducer
Take out the white cap from zero port
Zero to monitor
Open flow from patient to transducer.
Change with the yellow cap
3
4
5
Central Venous Catheter
6
Indication for Placement
Pre-existing Cardiovascular Disease
Surgical Procedure
Rapid Infusion of Fluids
Venous Blood Sampling
7
Target Market
Anesthesiology
Surgery
Critical Care Units
Burn Units
Emergency Rooms
8
Placement Sites
Internal Jugular
External Jugular
Subclavian Vein
Brachial Vein
9
10
11
Insertion Sites
12
Insertion Sites
13
Basic Set of CVC kit
Central Venous Cath Optional Items :
Dilator 7Fr, 8Fr, 8,5Fr 1. Needle sponge & veni
.035” guidewire J” tip quard
5cc Syringe 2. Y-Valve needle
Scalpel # 11 – short 3. Three way stopcock
Suture Wing with clamp
Needle 18ga x 2 3/4
14
Insertion Procedure with Seldinger
or Modified Seldinger Technique
Locate the appropriate vein
Insert the guide wire needle
Verify the venous site by
pulsatile flow
Insert the guide wire through
the needle till agequate
depth
Remove the needle leaving
the guidewire in place.
Note : Do not attempt to pull
back the guidewire as this
may cut the guidewire (Use
the dilator and scalpel to be
enlarge the puncture site)
Maintain a firm grip on the
guidewire at all times
15
Insertion Procedure
Prepare the catheter for insertion by flushing each lumen and
clamping
Leave the distal pigtail uncapped for the guidewire threading
Thread the CV Cath over the guidewire to proper depth using a
twisting motion
Hold cath at the desired depth and remove the guidewire
completely
Note : Do not use excessive force to remove the guidewire as it
is possible to be lodged or bent around the catheter
Secure the catheter to the patient via the slide clamp and suture
wings to prevent cath migration
16
Features
Superior geometric soft tip design couple with unique soft blended
bio-compatible material make insertion safe and easy.
Special design guidewires that has a soft flexible tip and prevent
vesset perforation (vascular trauma), yet has excellent stiffness that
provide torque to ensure firm insertion.
17
Port Usage
Proximal : Blood Sampling
Medications
Blood Administration
Medial : Total Parenteral Nutrition
Medications (only if TPN use is not
anticipated)
Distal : CVP Monitoring
Blood Administration
High volume or Viscous Fluids
Colloids
Medication
4th Lument : Infusion
Medications
18
Model Description
Available in Single lumen, 2 lumen and
3 lumen
4 lumen only available for 8.5Fr
Sizes – 4Fr, 5.5Fr, 7Fr, and 8,5Fr
Tubing Diameter for 7Fr : 7 x 0.33 or 7/3
: 2.31 mm
19
Model Description
Example :
CV – 703-20
7 French 3 Lumen 20 cm (length)
20
Difference Between
CV-703-xx & CV-713-xx
703 – Lumen Size is 16G/18G/18G
Distal : 16G (1.041 mm)
Middle : 18G
Proximal : 18G
*713 – Lumen Size is 14G/18G/18G
Distal : 14G (1.20 mm)
Middle : 18G
Proximal : 18G
21