Arc 510: A Mixed-Use Development: AFIYA RAISA 1631462020
Arc 510: A Mixed-Use Development: AFIYA RAISA 1631462020
Arc 510: A Mixed-Use Development: AFIYA RAISA 1631462020
SITE DESCRIPTION
ACCORDING TO DAP (2016-2035):
PROBLEMS IN TIA:
• LACK OF PROPER PLAYING FIELD AND PARK.
• LACK OF PROPER WASTE DISPOSAL AREA.
• LACK OF PROPER ROAD CONNECTIVITY FROM BADDA.
• LACK OF PROPER WATER TREATMENT FACILITIES.
OPPORTUNITIES IN TIA:
• HATIRJHEEL RECOGNIZED AS A PRIMARY COMMUNITY
SOCIALIZATION HUB.
• OPPORTUNITIES OF INCREASING MIXED-USE DEVELOPMENTS.
• MRT-06 WILL BE AVAILABLE ON THE SOUTH-EAST OF TEJGAON
INDUSTRIAL AREA.
DAP ANALYSIS
PROGRAM PROPOSAL:
ACCORDING TO DAP (2016-2035),
TEJGAON INDUSTRIAL AREA IS INDICATED AS A MIXED-USE ZONE.
KEEPING IN MIND THE PRESENCE OF MULTIPLE EDUCATIONAL INSTITUTIONS IN CLOSE VICINITY, A PROPOSAL TO DESIGN A MIXED-
DEVELOPMENT INVOLVING A STUDENT HUB AND A PUBLIC REALM IS GIVEN.
SINCE PARKS ARE OFTEN LOOKED AT AS LAND BEING WASTED, WE CAN OFTEN SEE PARKS BEING BARRED OFF OR ILLEGALLY OCCUPIED TO
BE CONVERTED INTO PROFIT INCENTIVE DEVELOPMENTS. THEREFORE, AN IDEA OF A VERTICAL PARK IS PROPOSED. WITH THE SAME
AMOUNT OF LAND BEING PROVIDED BUT IN VERTICAL MANNER MAY GIVE IT A SENSE OF INCREASED FUNCTIONALITY IN A MORE
COMPACT AREA
PROGRAM PROPOSAL
SITE DESCRIPTION: FAR CALCULATION:
20 KATHA PLOT; 6m ROAD WIDTH
SETBACK:
FRONT = 1.5m SIDES = 1.25m BACK = 2m
PARKING CALCULATION:
20 KATHA = FOR EVERY 200sqm (2152 sft) , 1 CAR PARKING MUST BE PROVIDED
THEREFORE, 15 PARKING SPACES MUST BE PROVIDED
FAR CALCULATION
SITE ANALYSIS
FIG. NOISE LEVEL
ENVIRONMENTAL SURVEY
CONTEXTUAL ANALYSIS
PROGRAM DESIGN & ZONING
CASE STUDIES
FIG. TYPICAL FLOOR PLAN
S
T
U
D
I
E
S
PHASE 4: THE FORM IS FURTHER PHASE 5: BRIDGES INTRODUCED TO INCREASE PHASE 6: RAMP CREATED TO INCREASE THE
FRAGMENTED TO INCORPORATE OPEN- CONNECTIVITY AND FURTHER INCREASE THE EXPERIENTIAL QUALITY OF THE PARK. FURTHER
TO-SKY STEP TERRACES FOR THE VERTICAL PARK FEATURE THROUGHOUT THE FRAGMENTATION AND TERRACING INTRODUCED FOR
VERTICAL PARK BUILDING VENTILATION AND WIND FLOW.
D A
6m WIDE RO
NOT TO SCALE
SOUTH-EAST ELEVATION
SOUTH-WEST ELEVATION
3D VISUALIZATION OF GROUND FLOOR LOBBY
SPACE
3D VISUALIZATION OF GROUND FLOOR PARK
AREA
3D VISUALIZATION OF GROUND FLOOR PARK
AREA
NOT TO SCALE
WALLS
CONSTRUCTED OF
CONCRETE
HOLLOW BLOCK
PLANTER BOX
ACTS AS A
SHADING DEVICE
FOR THE FLOOR
BELOW
DORMITORY DETAILS
SECTION BB’
3D VISUALIZATION OF DORMITORY COMMON
SPACE
3D VISUALIZATION OF DORMITORY COMMON
SPACE
CONVERTIBLE ROOM TYPES
DOUBLE OCCUPANCY ROOM LAYOUT 190 SFT