About Aptest NDT
 Aptest NDT Services was established to cater the advanced Non-destructive Testing needs for the core
industries like Powerplants and Refineries in the Middle East and across the globe.
 Aptest serves multiple industry verticals such as Power Generation, Petrochemicals, Automotive,
Construction etc.
 Priority on inspection, integrity and teamwork is our "prime directive".
 The company focus is on hands-on expertise with an emphasis on rapid response and personal
attention to the client’s requirements.
 Aptest includes approaches to allow for an increase in your plant availability and cost savings, ensure
minimum duration of shutdowns, enable you to modify your inspection strategy and improve safety
compliance issues.

www.aptestndt.com
Non-Destructive Testing
 In order to evaluate the component without causing damage is the principle of Non Destructive Testing
(NDT), Non Destructive Inspection (NDI), Non Destructive Evaluation (NDE).
 It is a highly valuable technique that can save both money and time in product evaluation, trouble
shooting.
 It is very difficult to weld or mold a solid object that has the risk of breaking in service, so testing at
manufacture and during use is often essential.
 During the process of casting a metal object, for example, the metal may shrink as it cools, and crack or
introduce voids inside the structure.
 During their service lives, many industrial components need regular nondestructive tests to detect
damage that may be difficult or expensive to find by everyday

www.aptestndt.com
NDT Methods

The seven most frequently used test methods are

• Leak Testing
• Helium Leak Testing
• Ultrasonic Testing
• Magnetic Particle testing
• Liquid Penetrant Testing
• Visual testing
• Eddy Current Testing

www.aptestndt.com
NDT Services in Aptest

Aptest has marked its presence in NDT throughout the length and
breadth of the country and beyond its horizon in Middle East countries.

• Helium Leak Testing • IRIS Inspection

• ECT Tube Inspection • PAUT/TOFD Inspection

• Eddy Current Testing • Ultrasonic Testing

• RFET Inspection • Hardness testing

• Magnetic Flux Leakage • Visual testing

www.aptestndt.com
Industries we serve

Aptest’s highly skilled teams are known to constantly endeavor to


develop innovative and superior solution for all its customers.

Refineries Power Plants Automotive

www.aptestndt.com
Our Expertise

We are Leak Testing experts !

HELIUM LEAK TEST FOR VACCUM CHAMBER LEAK ONLINE HELIUM LEAK
VALVES TEST TESTING

CONDENSER TUBE LEAK FREEZE DRYER/ FUGITITIVE EMISSION TEST


TESTING LYOPHILIZER LEAK TESTING FOR VALVES

www.aptestndt.com
Helium Leak Testing
Aptest NDT Services supply Helium Leak Testing based
solutions; we offer a wide range of different Helium leak
testing solutions to meet our customer requirements.

We specialize in Helium leak testing, which, among all,


represent the ideal solution for leak testing in Power
Plants, Leak Testing in Refineries, Leak testing in Medical
Equipment like Freeze Dryer/ Lyophilizer. This Helium
leak testing method is characterized by a very high level
of sensitivity and reliability.

Helium Leak Testing has the possibility to partly or fully


automate the process, integrating it directly into the
manufacturing line too if required.

www.aptestndt.com
Eddy Current Tube Inspection
Eddy current testing is a well-established method of
nondestructive testing that is used to examine
nonferrous/nonmagnetic materials such as condenser
and heat exchanger tubes in power generation plants.
Eddy current testing reveals discontinuities in tubing,
provides plant engineers with an accurate assessment
of a unit’s condition, and is a tool for predicting the
remaining useful life of the tubes.

Along with condenser and heat exchanger tube


cleaning and leak detection applications, many power
generation plants with aging units include eddy
current testing in plant maintenance programs in an
overall effort to maximize the efficient life of their
units.
www.aptestndt.com
Remote Field Testing
Remote Field Testing or commonly called as RFT is an
electromagnetic testing method used to detect
discontinuities in small diameter ferromagnetic
(Carbon steel) tubes and pipes. RFT - Remote Field
Testing is essentially a through transmission test
method wherein the receiver coil detects
electromagnetic field which has traversed through the
tube wall.

The basic RFT - Remote Field Testing probe consists of


two coils (or multiple in pairs) in a send-receive
configuration. Exciter coil is energized with a low
frequency Alternating current to send a magnetic flux
to the detector coil which is located at approximately
2-3 times the outer diameter of the tube under test.
The magnetic flux travels radially through the tube
wall to the outside diameter, then propagates axially
and then traverses back through the wall reaching to
the detector coil.
www.aptestndt.com
Internal Rotary Inspection System (IRIS)
Many plant operators in the oil, gas and power
generation industries are faced with the challenges of
maximising the efficiency and life expectancy of their
assets but without sacrificing safety and reliability.
Therefore accurate inspection of vital components
such as pipes and tubes is crucial to ensuring the
integrity of the plant.

Internal Rotary Inspection System (IRIS) can detect


corrosion, pitting and wall loss and is most commonly
used for tube inspection in boilers, heat exchangers,
air coolers and feed water heaters. It is particularly
versatile as it is suitable for both ferrous and non-
ferrous materials, and IRIS can be used on a wide
range of tube diameters and wall thicknesses.

www.aptestndt.com
Advanced PAUT Inspection
PAUT is an advanced inspection method used to detect
discontinuities components such as cracks and flaws.
This method is considered very powerful and flexible
in detecting defects at it is possible to control few
parameters such as beam angle and focal length.

Phased Array UT - PAUT inspection can also be used


for variety of applications like measuring wall
thickness and corrosion testing.

Phased array UT - PAUT is used in wide range of


applications,

• Weld Inspection
• Corrosion Mapping
• Thickness measurements

www.aptestndt.com
Advanced TOFD Inspection
Time-of-flight diffraction (TOFD) method of ultrasonic testing is a
sensitive and accurate method for the nondestructive testing of
welds for defects. Phased Array with TOFD combination is
commonly used to inspect pipeline welds.

The Time-of-Flight Diffraction (TOFD) method can be regarded


more and more as a standard NDT technique in an increasing
number of countries. Nevertheless, there is still a considerable
amount of development work going on.

Time-of-Flight Diffraction Ultrasonic Testing is among the most


modern testing methods for the detection of imperfections and
defects in materials. Conventional Ultrasonic Testing uses sound
reflection. ToFD testing measures the time-of-flight of an
ultrasonic pulse to determine the position of a reflector. The
application of this method is fast and extremely accurate. This has
resulted in an increasing popularity over the last few years.

www.aptestndt.com
UT Plate, Rod & Weld Inspection
UT - Ultrasonic Testing

Ultrasonic nondestructive testing, also known as ultrasonic


NDT or simply UT, is a method of characterizing the
thickness or internal structure of a test piece through the
use of high frequency sound waves. The frequencies, or
pitch, used for ultrasonic testing are many times higher
than the limit of human hearing, most commonly in the
range from 500 KHz to 20 MHz.

UT is used in wide range of applications,

• Weld Inspection
• Corrosion Mapping
• Thickness measurements

www.aptestndt.com
To Conclude

Aptest has marked its presence in The Middle East countries in all testing
methods listed below.

• Helium Leak Testing • IRIS Inspection

• ECT Tube Inspection • PAUT/TOFD Inspection

• Eddy Current Testing • RFET Inspection

www.aptestndt.com
We do more and better !
Get to us, Lets work together !

www.aptestndt.com

You might also like