Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EcoStruxure IT Product Overview - Partner R

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 62

EcoStruxure IT Solution

Noval Mulia, Presales Consultant, Data Center Software Solution

Internal
EcoStruxure for Data Center - intro

EcoStruxure IT - intro

NetBotz

StruxureWare Data Center Expert

EcoStruxure IT Expert (ITE)

EcoStruxure IT Advisor ( ITA )

Confidential Property of Schneider Electric | Page 2


Internal
EcoStruxure Architecture
1 EcoStruxure Architecture, Serving 4 End Markets with 6 Domains of Expertise

Building Data Center Industry Infrastructure

Apps, Analytics & Services


Cybersecurity
Cloud and/or
On Premise
End to End

Edge Control

Connected Products

EcoStruxure For Data Centers

EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure


Building Power IT Machine Plant Grid

Internal
integrates connected products, software and services across
Power, Cooling and the IT room

Unified Operations ETAP Design &


Center Simulation

Domains of Expertise BUILDING IT POWER

Internal
EcoStruxure IT solution suite
Covering all data center types to support our customer’s dynamic environments
Custom Solutions & Integrations

Tailored solutions to the customers


Planning & Modeling Planning, modeling, and optimization needs and requirements
of critical IT infrastructure

Monitoring and Management

Critical power and cooling infrastructure Physical security


monitoring and device management and environmental EcoStruxure IT – Custom
monitoring EcoStruxure IT Advisor
Solutions
On-premises and cloud-based software  Reports
 Dashboards
 Process automation
 Integrations
 Migrations
 Features
Cooling Optimize
Dynamic Cooling Control
Optimize cooling, reduce hot
EcoStruxure IT Data Center Expert NetBotz spots and save energy by
Expert On-premises software Appliances and sensors leveraging machine learning to
Cloud-based software control individual cooling units.
On-premises

Integrations with MSP / partner


story

Confidential Property of Schneider Electric | Page 5

Internal
Netbotz Overview
Security & Environmental Monitoring

Property of Schneider Electric


Introduction to Netbotz

Provides surveillance, badged rack access and environmental sensing – ALL IN ONE

Property of Schneider Electric | Page 7


Common
Access
Environmental Risks
Control Risks
Water, heat, and equipment failures accounted for 11 percent of all
data center outages in 2016.

BREACHED ENCLOSURES

OVERHEATING FLUIDS/LEAKS HIGH HUMIDITY

ENCLOSURES LEFT OPEN


FIRE/SMOKE
8
New APC NetBotz Portfolio
New 750, 755, and 165 will seamlessly drop into rest of NetBotz Ecosystem

Intelligent Appliances Pods Rack Access Sensors

NetBotz Rack Monitor 750


Wireless Temperature Temperature Temperature & Humidity
Camera Pod 165 NetBotz 250 & Humidity
(NBACS125 & NBACS1356)

Dry Contact Leak Rope 0-5 V Sensor


Sensor Pod Rack 150
NetBotz Wall Monitor 755
(RTS July 2020)

Rack Access Pod 175


Spot Fluid Vibration Smoke
(RTS Q4 2020)
NetBotz Rack Monitor 250 Sensor Pod Wall 155 (v2 125 kHz and 13.56 MHz handles)

Beacon Door Contact

Confidential Property of Schneider Electric | Page 9 Internal


About the Netbotz 750
NBRK0750

An active monitoring solution:


• DESIGNED to protect against environmental and physical threats to IT infrastructure.

• WORKS in both Edge Compute & Data Center environments.

• Its INTEGRATED suite of sensors, access control pods, & camera pods safeguards environments with surveillance and
flexible alerting.

Property of Schneider Electric | Page 10


Detailed Layout
NetBotz 750 provides maximum flexibility to protect complex IT deployments …

Property of Schneider Electric | Page 11


About the Netbotz 755
NBWL0755 / 756
• Manage up to 4 cameras (3 external plus 1
integrated), 47 wireless sensors, 16 wired
sensors, and badge access control for 1 rack
through expansion pods
• Support for the HD & low-light NetBotz Camera
Pod 165
• Alarming via email or SNMP based on user-
configurable thresholds
• Local clip capture from cameras when motion is
detected or other alerts occur
• Integration with StruxureWare Data Center
Expert for long-term data and video storage
• Requires POE Type 2 or POE+ (IEEE 802.3at)
• NBWL0756 should come with new POE Injector
NBAC0303NA2
Property of Schneider Electric | Page 12
Detailed Layout

Property of Schneider Electric | Page 13


Netbotz 250 Detailed Layout

Removable wireless A-link input & Modbus Relay Mini USB


Beacon
coordinator via USB output Ports Output Console Port

Rack access control 6x RJ45 sensor 10/100 network


Switched outlet Door contact sensor
handle input ports connection **

Property of Schneider Electric | Page 14


Sensors and Pods
The 750 and 755 will support the existing sensor & pods

AP9335T AP9335TH NBES0304 NBES0308 NBES0305


NBWS100T / H NBES0309 Leak Rope
Extension

Door Switch Sensor Door Switch Sensor


for Doors or 3rd Party for APC Rack
NBES0301 NBES0306 NBES0307 AP9324 Racks
NBES0302 NBES0303

Netbotz Comptibility Matrix


Property of Schneider Electric | Page 15
Wireless Sensors

The Netbotz 750 supports up to 47 Schneider ZigBee-based sensors and/or routers.


This creates a wireless network of sensors that supply Temperature & Humidity readings.

• It uses the NBWC100U as Coordinator.


It collects readings from NBWS100T & T/H sensors (also known as “End devices”).

• The maximum range of the sensors are 30 meters, line of sight (100 feet).
By putting the NBWC100U in router mode, you can extend this range. In a data center environment where obstructions
are common, a range of 15 m (50 ft) is typical.

• To function as a router, the NBWC100U must be powered by a USB connector.


NBWC100U as a
(NOT the Coordinator port of an appliance)
Router
• The Coordinator can be extended by using repeater cables.
(NBAC0213L or NBAC0213P) Wireless
Sensors

NBWC100U as a
Coordinator
Property of Schneider Electric | Page 16
Camera Pod 165
NBPD0165

4MP IP-based POE High-Definition Camera with low-light capability, natively managed by
NetBotz devices, 750 or 755. Max resolution of 1920x1080, 1080p

Property of Schneider Electric | Page 17


Image Comparison
Camera Pod 160 and Pod 165 (Lights on)

Pod 160 Pod 165

Property of Schneider Electric | Page 18


Image Comparison
Camera Pod 160 and Pod 165 (Lights off)

Pod 160 Pod 165

Property of Schneider Electric | Page 19


Netbotz 5 & DCE
Configuration Overview
Netbotz 750

The 750 supports


• New camera pod 165 (4 x NBPD0165)
(Other Onvif Camera may work but not fully tested)

• Rack access pods (170 or 175)


12 Rack Access Pods NBPD0170 / 175

• Sensor pods (150 or 155)


Max of 12

• 2 directly attached handles


(NBHN125/1356 types)

• Wireless sensors/routers
(NBWC100U, NBWS100T&T/H x 47)

• AP9520TH max of 8

• Can support up to 10 downstream devices


on the Private LAN side

Property of Schneider Electric | Page 21


Configuration Overview

IP
• New camera pod 165 (4 x NBPD0165) NETWORK
(Other Onvif Camera may work but not fully tested) NetBotz 755
Requires Only One
• Rack access pods (170 or 175) IP Address
WebUI
Only 1 Rack Access Pod with supplemental power Management
supply is supported WIRELESS

• Sensor pods (150 or 155) POE


Supporting Up
Its recommended to use an AP9505i on every fourth To
Pod (3) IP Cameras
Wireless
(Only 1 POE Sensors
1x Rope Leak Port) 47x T and/or TH
• Wireless sensors/routers Sensors 50 ft [15 m]
(NBWC100U, NBWS100T&T/H x 47) (dedicated range
port)
• AP9520TH max of 4
Rack
• Can support up to 10 downstream devices on Access
the Private LAN side Control

6x Universal 6x Universal Sensors


Sensors
Property of Schneider Electric | Page 22
StruxureWare Data Center Expert
IT Infrastructure and Device Monitoring

On-premise

Centralized monitoring, quick resolution of events, vendor neutral.


Features Benefits
Centralized management Simplify management of the physical infrastructure using a centralized
repository accessible from anywhere on the network through a powerful
and easy-to-use console application.

Monitoring Immediate visibility to your entire physical infrastructure through


centralized, real-time device monitoring and notification enabling quick
assessment of events as they occur.

Fault notification Event notification minimizes response times to critical physical


infrastructure situations. Enables IT Administrators to reduce mean time to
repair, improve efficiency, and maximize uptime.

Multi-vendor device Extensive multi-vendor support for monitoring networked SNMP devices.
support Enable visibility of existing SNMP devices through threshold alert
notifications, data trending and reporting

Confidential Property of Schneider Electric | Page 23


Internal
IT Advisor Battery Monitoring
30x EasyLogic PM2130
Systems
Power & Energy Meter
Fire Alarm Panel

VESDA
Data Center Expert

NetBotz 750#1 EcoStruxure EGX#5 EGX#4 EGX#3

LA
N
EGX#1
EGX#2
NetBotz 750#3

UPS ATS

2x Digital Multi Meter


(AVR-Lovato
Cooling Units Electric)

EcoX Rack PDUs


SNMP / TCP-IP
RS485 / MODBUS
Architecture Busba
Dry
r
Data Center Expert

Web Service

SNMP /
MODBUS

Critical Infrastructure Feature


Centralized management
Real-time monitoring
Fault notification
Multi-vendor device
support

Internal
DCE Web Client

Confidential Property of Schneider Electric 26

Internal
DCE Web Client (Gadgets)

Multiple Gadgets can be added on the home page

Confidential Property of Schneider Electric 27

Internal
DCE Web Client (Gadget examples)

Multiple Gadgets can be added on the home page

Confidential Property of Schneider Electric 28

Internal
DCE Web Client (Monitoring – device info)

Once selected, detailed device information will be shown

Confidential Property of Schneider Electric 29

Internal
DCE Web Client (Monitoring – intervals)

Sensor information shown for the selected sensor & time interval

Confidential Property of Schneider Electric 30

Internal
DCE Web Client (Event Log)

Event Log based upon selected Category & Time Range

Confidential Property of Schneider Electric 31

Internal
DCE Web Client (Search)

Search makes it easy for users to find device alarms & sensor information

Confidential Property of Schneider Electric 32

Internal
DCE Client GUI

33

Internal
DCE Client GUI - cont

34

Internal
DCE Client GUI - cont

35

Internal
DCE Client GUI - cont

36

Internal
Cloud-based

EcoStruxure IT Expert
simplifies local edge and
distributed IT monitoring

Centralized Vendor Benchmarking Assessments Alarm


monitoring agnostic consolidation

Data remains secure and private


at every step of the user journey

Confidential Property of Schneider Electric | Page 37


Internal
EcoStruxure IT Software & Services – Empowering YOU

YOUR PREFERRED
PARTNER
24/7 SERVICE BUREAU
COVERAGE
EcoStruxure IT
for Partners Actionable
insights EcoStruxure
24/7 extra pair of eyes Asset Advisor
Multi-tenant
Assessments
interface

Expert
recommendations

EcoStruxure IT Advisor
EcoStruxure IT Expert
Insights
through report

Deploying the future Analytics Monitoring

YOUR WAY
DO IT YOURSELF

Customer Success Management

Partner Success Management

Facility Operations
Confidential Property of Schneider Electric | Page 11

Internal
Page 39
IT Expert - Sensor

Internal
Page 40
ITE – Custom Dashboard

Internal
Page 41
IT Expert - Dashboard

Internal
Page 42
IT Expert - Assessments

Internal
Full off premise visibility
EcoStruxure IT increases transparency of critical equipment through live sensor data , alarms delivered
directly to your smartphone (no need for VPN)

Equipment status and Alert notifications Active alarms


live sensor values
Confidential Property of Schneider Electric | Page 43
Internal
DCIM Solution Design Process

Requirement Solution
Analysis Integration Design (ISX Scope of
BoQ
(Tender, Document Designer, Work
Prebid) Design Portal)

Internal
Page 45
IT Expert - Partner View

Internal
EcoStruxure IT Advisor
• ITA Base Software
• Introduction

Confidential Property of Schneider Electric |


Internal
Top 3 problems solved by EcoStruxure IT Advisor

Delayed server deployment Downtime Location, location, location

Capacity optimization Proactive simulation of changes Inventory management

Assures that your physical Analyzes data center infrastructure Provides an overview of the physical
infrastructure provides the redundancy, and highlights redundancy location of assets as well as its relation
backup time and availability required. vulnerabilities through impact to the environment for full visibility into
simulation your data center.

Confidential Property of Schneider Electric | Page 5


Internal
IT Advisor is available
Stay on top of everything cloud-based and
on-premise
IT Advisor enables…

Capacity planning Risk planning


Know where to place Can you safely shut down
the next server by a device or do you need
planning and to reduce the IT load
analyzing the first? The Impact
infrastructure. Analysis report
indicates how incidents
Change management may impact your devices Colocation
Reduce human error and and infrastructure. Understand the current
deploy best practice state of your colocation
across all moves, adds, infrastructure. IT Advisor
and change with offers floor view with
workflow automation. areas, cages and racks,
and IT assets colored
according to status,
along with detailed floor
and rack utilization
reports.

Confidential Property of Schneider Electric | Page 48


Internal
Available cloud-based
IT Advisor (formerly known as Colo in StruxureWare Data Center Operation) and on-premise

Operations Management

Data center optimization Manage data center assets, operational and capital costs
• Floor and rack management
• CAD import Features Benefits
• Asset management Inventory management Shows device data within the physical layout for instant access to device details
• Cage management and asset attributes, and overview of data center operations.
• Customer info
• Tenant Portal Floor Layout Visualize data center floor layout and its assets such as racks in both 2D and 3D.

Web client Allows the user visibility into the data center assets using any modern web browser

Genome Library Ever growing library of product catalog that contains up-to-date floor and rack
mounted data center equipment.

For Colo providers Visualize space available for selling on to tenants, lightweight web based tenant
portal.

Confidential Property of Schneider Electric | Page 49


Internal
Available cloud-based
IT Advisor (Base Module) and on-premise

Inventory Management

Data center optimization Manage data center assets, operational and capital costs
• Floor and rack management
• CAD import
Features Benefits
• Asset management Inventory management Shows device data within the physical layout for instant access to device details
• and asset attributes, and overview of data center operations. Integrates with HP
Change management
OneView and HP uCMDB (available on-premise only)
• Capacity planning
• IT equipment guidance / Instant server placement recommendation through real-time analysis of available
Risk planning change and capacity data center capacity, including power, cooling, u-space, network and power ports,
• Reporting capacity strategies, weight limits and more.
• Energy efficiency and cost Automated work order Create work orders and automatically generate tasks to move, add or change IT
• Advanced power setups process and infrastructure equipment. Schedule, assign and track the status of itemized
• Server Usage Optimization tasks to implement changes in the data center.
• High availability Consolidated data center Gain transparency to data center key performance indicators through easily
• Cage management dashboard configured web dashboards, displaying customizable management-level
information
• Customer info
• Audit trail Track all IT and facility equipment changes over the data center lifecycle, ensuring
Energy consumption tracking
transparency and easy identification of maintenance requirements.
• Tenant Portal
Web client Allows the user visibility into the data center assets, power usage and power
capacity using any modern web browser

Confidential Property of Schneider Electric | Page 50


Internal
IT Advisor Desktop Client
… an instant overview of a DC’s operations

• Key features:
– Inventory management
– Alarms within physical layout
– PUE/DCiE calculator
– CAD import and export
– Floor plan for large buildings Web Client
– Grid based naming
– Network management
– Global asset search
– Genome library
– Live Portal and Web Client
– Ability to integrate with
3rd Party Systems
Inventory Management Available cloud-based
and on-premise

EcoStruxure IT Advisor provide location-based drill-down view provides a structured


overview of data center locations, from a global to local view down to single assets

Confidential Property of Schneider Electric | Page 52


Internal
Available cloud-based
IT Advisor: Capacity and on-premise

Simulation, planning, and optimization of infrastructure capacities to right-size the data center

Features Benefits
IT equipment guidance Instant server placement recommendation through real-time analysis
of available data center capacity.

Available capacity Global view of available capacity within an organizational context,


providing an instant calculation of actual space, power and cooling
consumption, power and network port availability and floor and rack
weight limits against overall data center capacity constraints
Business impact Shows the consequence of device failure on data center
infrastructure equipment for instant identification of critical business
application impacts.
3D airflow analysis Track all cage and facility equipment changes over the data center
lifecycle, ensuring transparency and easy identification of
maintenance requirements.

Virtualization Integrations with VMware vSphere and HP OneView from the IT layer
capabilities and the physical infrastructure layer, enabling data center managers
to automatically migrate their impacted virtual machines from an
impacted host server to a healthy host server (available on-premise
only).

Predicted Power Provides rack and breaker level capacity planning and provides the
potential to unlock stranded capacity as estimated load values are
automatically derived from actual power measurements.

Confidential Property of Schneider Electric | Page 53


Internal
3D Temperature Data Available cloud-based
and on-premise
EcoStruxure IT Advisor visualize measured as well as calculate temperature data in DC

• Calculate and display the cooling performance of the DC Space in real-time with CFD-like simulation,
providing the measured and calculated inlet and exhaust temperatures per rack plus capture index per rack
• 3D view showing max/average inlet/return temperature

Internal
Available cloud-based
IT Advisor: Change and on-premise

Fully integrated workflow management for your IT physical infrastructure

Features Benefits
Automated work Create work orders and automatically generate
order process tasks to move, add or change IT and infrastructure
equipment.

Advance Users can now design, allowing them to set up both


workflow
template parallel and sequential workflows and the
dependencies between the individual tasks
.
Asset audit trail Track asset moves, adds and changes by
date/time, owner and work orders for view, print
and export.
Change Interactive interface showing past and pending
management changes to assist with resource and workload
overview balancing, avoiding scheduling conflicts.

Link tickets to Associate BMC Remedy change tickets with Data


work orders Center Operation: Change work orders, as well as
view and filter BMC Remedy tickets for an
overview of current workload.
Confidential Property of Schneider Electric | Page 55
Internal
Available Capacity Available cloud-based
and on-premise
EcoStruxure IT Advisor provide visibility of DC capacity in terms of power, cooling,
rack U space & physical network ports

Confidential Property of Schneider Electric | Page 56


Internal
Asset Provisioning EcoStruxure IT Advisor recommends where to best place new server Available cloud-based
and on-premise

Not Recommended

Some Concerns

Recommended

Internal
Available cloud-based
IT Advisor: Change and on-premise

Fully integrated workflow management for your IT physical infrastructure

Features Benefits
Automated work Create work orders and automatically generate
order process tasks to move, add or change IT and infrastructure
equipment.

Change Request Build forms to allow users to request changes in data


center.
.

Asset audit trail Track asset moves, adds and changes by


date/time, owner and work orders for view, print
and export.

Change Interactive interface showing past and pending


management changes to assist with resource and workload
overview balancing, avoiding scheduling conflicts.

Link tickets to Integration capability with BMC Remedy,


work orders associating its change tickets with Data Change
work orders, as well as view and filter BMC
Remedy tickets for an overview of current work
load.
Confidential Property of Schneider Electric | Page 58
Internal
Change Management Available cloud-based
and on-premise
EcoStruxure IT Advisor tracks changes request approval as well as work order tasks to add, move or remove rack assets

Change Request

Work Order

Work Order Tasks

Internal
Available on-premise
IT Advisor: IT Optimize
In-depth optimization of server utilization for increased data center performance and reduced IT system energy usage

Features Benefits
IT power and Determine the business usefulness for all IT assets
utilization helps eliminate underutilized servers and maximize
monitoring IT capacity at the rack, row and room level.

Track Reduce costs by eliminating unnecessary servers


underutilized and maximize efficiency and rack capacity.
servers
Server usage Enables businesses to capture and assign IT costs
chargeback to individual departments for accurate billing
support down to the physical or virtual server level.
GenomeTM library The continuously growing asset library enables the
software to determine power consumption without
the aid of hardware sensors.

Power / CPU Provides auto-discovery of assets managed by


utilization Cisco UCS Manager, enabling data center
managers to monitor the CPU/power utilization
along side utilization at the physical infrastructure.

Confidential Property of Schneider Electric | Page 60


Internal
Let’s get in
touch
ecostruxureit.com

Contact me
Noval Mulia | 0823-8801-2533| noval.mulia@se.com
© 2021 Schneider Electric, All Rights Reserved | Page 61
Internal

You might also like