Huawei CloudEngine S Fixed Series Switches Technical Main Slides
Huawei CloudEngine S Fixed Series Switches Technical Main Slides
Huawei CloudEngine S Fixed Series Switches Technical Main Slides
• TTM of new services shortened • SDN-based architecture • Consistent experience of each • Ultra-broadband: 100G and
form months to days • Remote configuration delivery application for each user at each high-density 10G
• Differentiated requirements of and deployment moment
• Based on VXLAN and EVPN
different services • Multi-branch management. • Fast fault locating and analysis
• One network for multiple purposes
• Fault prediction and AI-powered
dynamic learning
S6330-H
S6330-H24X6C S6330-H48X6C
S5332-H
S5332-H24S6Q S5332-H48S6Q
S5335-S
S5335-S24T4X S5335-S24P4X S5335-S32ST4X S5335-S48T4X S5335-S48S4X S5335-S48P4X
2 Product Highlights
3 Application Scenarios
Redundant power The power modules of all models are hot swappable and support 1+1 redundancy backup. By default, the power modules are
supplies not included.
NetStream/Telemetry Supported
Ports 20 x GE (SFP), 4 x 10GE (SFP+), and 6 x 40GE (QSFP+) 44 x GE (SFP), 4 x 10GE (SFP+), and 6 x 40GE (QSFP+)
FIBv4 : 192K
FIB entries
FIBv6 : 80K
Redundant power The power modules of all models are hot swappable and support 1+1 redundancy backup. By default, the power modules are
supplies not included.
NetStream/Telemetry Supported
Redundant power The power modules of all models are hot swappable and support 1+1 redundancy backup. By default, the power modules are
supplies not included.
NetStream/Telemetry Supported
24*100/1000BASE-X,
24*10/100/1000BASE-T, 48*10/100/1000BASE-T, 48*100/1000BASE-X,
ports 8*10/100/1000BASE-T,
4*10G SFP+ 4*10G SFP+ 4*10GE SFP+
4*10GE SFP+
iStack Unsupported
FIBv4 : 8K
FIB entries
FIBv6 : 3K
Redundant
power The power modules of all models are hot swappable and support 1+1 redundancy backup.
supplies
Surge
protection
specification ±10 kV in common mode N/A
(service port)
Surge
protection AC power port: ±6 kV in differential mode, ±6 kV in common mode
specification DC power port: ±2 kV in differential mode, ±4 kV in common mode
(power port)
Heat
dissipation Air-cooled heat dissipation and intelligent speed adjustment
24*100/1000BASE-X
12*10/100/1000BASE-T 24*10/100/1000BASE-T
ports 8*10/100/1000BASE-T
4*1000BASE-X 4*10GE SFP+
4*1000BASE-X
iStack Unsupported
FIBv4: 4K
FIB entries
FIBv6: 1K
Redundant
Built-in AC power
power supplies
Surge
protection
specification ±10 kV in common mode
(service port)
Surge
protection
specification ±6 kV in differential mode, ±6 kV in common mode
(power port)
Heat S5335-L12T4S-A:Natural heat dissipation
dissipation Others:Air-cooled heat dissipation and intelligent speed adjustment
2 Product Highlights
3 Application Scenarios
100G/40G
Aggregation
Huawei new-generation high-performance
layer aggregation switch
CloudEngine S6330-H
40G/10G
GE/10G
SEP
OAM
High Reliability: The new-generation ring network
The S5300 switches support OAM to
protection technology supports
implement end-to-end fault detection.
99.999%+ closed-ring, open-ring, and cascading
network topologies. SEP can work
with STP to provide 50 ms protection
switching.
Capabilities Benefits
• Simplified management: Hundreds of wired and wireless devices are virtualized
• Huawei is the industry's only vendor that supports a two-layer AS architecture. into a single device and only one management network element (NE) is required.
• Reuse of devices: No requirement is imposed on types of core and access Access switches and APs support plug-and-play deployment. Wired and wireless
devices. Devices on the live network can support SVF by upgrading software. networks use unified service configuration templates.
• Centralized management and control: After services are configured on core
devices and user-side ports of access devices are specified, services can be
automatically delivered to access devices. Automatic service delivery helps build
service-oriented networks.
As-Is: > Half a year To-Be: < One week Application Example
POP/BNG POP/BNG
Fiber/LL/ IP/MPLS
Enterprise Enterprise
SDH/SONET
DSLAM DSLAM
S6330-H MEP.1 MEP.2 S6330-H
Solution Advantages
Complete EOAM features: BFD, Y.1731, 802.1ag, 802.3ah
Fast link fault location: Rapidly detects faults on devices and links.
Service protection: Achieve fast link switching to ensure that services are uninterrupted.
Original flow statistics: Classifies packets based on the 7-tuple: Inbound / outbound interface index, source IP address, destination
IP address, source port number, destination port number, protocol type, and TOS field
Flexible flow statistics: Select any one or more of the six packet characteristics to collect packet statistics. Protocol type, TOS,
destination port, source port, destination IP address, and source IP address
Aggregation flow statistics: Supports ten aggregation rules.
NMS NMS
1 3
2
2
1 The engineer upload the configuration file to the TFTP/FTP/SFTP 1 Upload the configuration file to the USB storage device.
server.
2 The engineer deploys hardware 2 Hardware deployment
3 After the switch is powered on, it automatically obtains the allocated 3 After the switch is powered on, it automatically obtains the
IP address and FTP server address from the DHCP server. configuration file from the inserted USB medium.
4 Switch obtains the configuration file from the FTP server based on the 4 Configuring more services through the NMS
2 Product Highlights
3 Application Scenarios
Headquarters
Internet
AR G3
S63XX
S53XX
The S53XX series switches can be used as core/aggregation switches in small- and medium- sized
enterprises or branches of large enterprises.
To improve reliability, access switches can be dual-homed to two S53XXs or an S53XX stack. Stacking
simplifies device operations while enhancing reliability.
Partners Branch
Internet ISP WAN
Internet
DMZ
Intranet
S12700E Web server
Email server
DNS server
S12700E
S53XX/S63XX
The S53XX/S63XX series can be used as access switches on large-sized enterprise networks to provide
gigabit access. Stacking technology can be used to improve network reliability.
Internet WAN
NE router
S12700E
CSS
S53XX/S63XX
The S53XX/S63XX series can be used in a data center to provide access to gigabit servers and
connect to upstream devices by link aggregation. If many servers are deployed in a rack, an
S5300 stack can be used to facilitate network maintenance and improve network reliability.
Individual
Internet
S53XX
S12700E
HG S63XX
BRAS
MAN SoftX
DSLAM S63XX PE
STB
Enterprise SR Head-end
CPE
Corporate
S53XX S63XX
S53XX VoD server
Port Key
Product series combinations characteristics
S5300-H48T4X-A
A B C D
D Key characteristics (1 character) A: AC power supply D: DC power supply N/A: no power supply configured by default